Medium Lockout
S.41 on Vaillant ecoTEC Plus 840

Your boiler has detected that there is too much water in the system, which puts extra stress on the pipes and components.

Book a service

This fault should be looked at by a Gas Safe engineer within the next week or two. It may get worse if left.

Technical description

Water pressure > 2,9 bar

What causes this fault?

This fault occurs when the internal water pressure exceeds a safe limit, often because the filling loop used to top up the system has been left slightly open or is leaking. It can also happen if the expansion vessel, which manages heat-related pressure changes, has failed or lost its air charge. In some cases, a faulty heat exchanger can allow fresh mains water to leak into the heating circuit, causing the pressure to rise continuously.

This issue often surfaces when the heating is first turned on for winter, as the expansion of warming water puts extra stress on a system that might already be overfilled or have a failing expansion vessel.

DIY fix possible

Check that the internal or external filling loop valves are fully closed.Locate a radiator bleed valve and use a key to drain water into a vessel to reduce pressure.Monitor the pressure gauge until it reaches between 1.0 and 1.5 bar.Press the reset button if the boiler does not automatically restart.

Find a Gas Safe engineer
Search the official register →