The 6 most common faults
01
F.00 Engineer
Fault: Flow temperature sensor - NTC plug not plugged in or has come loose, multiple plug on the PCB not plugged in correctly, interruption in cable harness, NTC sensor defective
Full guide for F.0002
F.01 Engineer
Fault: Return temperature sensor - NTC plug not plugged in or has come loose, multiple plug on the PCB not plugged in correctly, interruption in cable harness, NTC sensor defective
Full guide for F.0103
F.10 Engineer
Short circuit: Flow temperature sensor - NTC sensor defective, short circuit in the cable harness, cable/casing
Full guide for F.1004
F.11 Engineer
Short circuit: Return temperature sensor - NTC sensor defective, short circuit in the cable harness, cable/casing
Full guide for F.1105
F.13 Engineer
Short circuit: Domestic hot water cylinder temperature sensor - NTC sensor defective, short circuit in the cable harness, cable/casing
Full guide for F.1306
F.20 Engineer
Safety switch-off: Overheating temperature reached - Incorrect earth connection between cable harness and product, flow or return NTC defective (loose connection), black discharge via ignition cable, ignition plug or ignition electrode
Full guide for F.20Call a Gas Safe engineer if…
- You can smell gas or see signs of a leak
- The Vaillant shows an Emergency or High severity code
- The boiler keeps locking out after repeated resets
- You've tried the DIY checks and the fault hasn't cleared
- There's visible water leaking from the boiler
- The flame is yellow or orange instead of blue