Common problems guide

The most common Viessmann Vitodens 111-W B1LD 26kW problems

The faults most likely to send a Viessmann Vitodens 111-W B1LD 26kW into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

28 documented codes
6 most common
0 DIY-safe checks
6 engineer needed

The 6 most common faults

01
0C High Engineer

The boiler has stopped because its burner is blocked or not getting a steady enough electricity supply, so it cannot light and heat your home or water safely until it is checked.

Est. cost
£120-350
Parts
Burner assembly, Burner gasket, Ignition electrode
Full guide for 0C
02
30 High Engineer

Your boiler has stopped because its sensor that measures the water temperature is reporting a fault, and it may also have a blockage in the burner, so it has shut itself down to stay safe until it's checked.

Est. cost
£120-220
Parts
Boiler water temperature sensor (NTC), Sensor wiring harness or connector, Burner cleaning kit or burner gasket
Full guide for 30
03
38 High Engineer

Your boiler has shut itself down because it has detected a problem with a temperature sensor and a possible blockage around the burner, so it needs a qualified engineer to check it.

Est. cost
£150-350
Parts
Boiler water temperature sensor (NTC), Sensor lead or wiring harness, Burner gauze or burner assembly
Full guide for 38
04
F9 High Engineer

The boiler's fan, which pushes air through the boiler to burn gas safely, isn't starting, so the boiler has shut itself down as a precaution and won't heat your home or water until it's checked.

Est. cost
£250-450
Parts
Combustion fan assembly, Fan connecting cable or harness, Main control PCB (circuit board)
Full guide for F9
05
F4 High Engineer

The boiler tried to light its burner but couldn't establish a flame, so it has stopped and is waiting for a reset, which usually means no heating or hot water until it's checked.

Est. cost
£120-350
Parts
Ignition electrode, Ionisation (flame sensing) electrode, Gas valve (gas train)
Full guide for F4
06
50 High Engineer

Your boiler has stopped heating your hot water because it has detected a fault with the sensor that measures the temperature in your hot water cylinder, and a qualified engineer will need to check it.

Est. cost
£120-220
Parts
Cylinder temperature sensor (B3), Sensor cable or connector
Full guide for 50

on the Viessmann Vitodens 111-W B1LD 26kW

Burner assemblyBurner gasketIgnition electrodeFanGas valveBoiler water temperature sensor (NTC)

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Viessmann shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 28-code list for the Viessmann Vitodens 111-W B1LD 26kW