01
F.59 High Engineer

Your boiler has stopped heating because its internal fan is not running correctly, which is a common fault that a registered engineer can usually fix.

Est. cost
£200-450
Parts
Fan assembly, Fan connection cable or harness, Gas valve or gas-air mixing unit
Full guide for F.59
02
F.457 High Engineer

Your boiler has stopped because its internal ventilation fan is not starting up, which it needs to do safely before it can heat your home or water.

Est. cost
£200-450
Parts
Combustion fan assembly, Fan connection cable or wiring harness, Main control PCB (if the fan signal fault persists)
Full guide for F.457
03
F.359 High Engineer

The boiler tried to light its burner but couldn't get a flame, so it has shut itself down to stay safe and needs a qualified engineer to check the ignition and gas supply.

Est. cost
£150-350
Parts
Ignition unit (ignition module), Ignition electrode, Gas valve
Full guide for F.359
04
F.357 High Engineer

Your boiler has stopped because it isn't getting the gas pressure it needs to light safely, so it's shut itself down to protect you and your home.

Est. cost
£120-350
Parts
Gas valve, Gas pressure switch, Gas train components
Full guide for F.357
05
F.368 High Engineer

The boiler is not getting the gas pressure it needs to light, so it has stopped and is waiting for the gas supply to be checked.

Est. cost
£90-250
Parts
Gas valve, Gas pressure switch, Gas filter
Full guide for F.368
06
F.369 High Engineer

The boiler's flame sensor is picking up a faint electrical signal even though no flame is burning, so the boiler has switched itself off as a safety precaution.

Est. cost
£100-250
Parts
Ionisation electrode, Burner gauze assembly gasket, Burner door gasket
Full guide for F.369

on the Viessmann Vitodens 200-W B2HE-19

Fan assemblyFan connection cable or harnessGas valve or gas-air mixing unitControl PCBCombustion fan assemblyFan connection cable or wiring harness

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Viessmann shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 170-code list for the Viessmann Vitodens 200-W B2HE-19