Common problems guide

The most common Vokera Vision Plus 35C/40C problems

The faults most likely to send a Vokera Vision Plus 35C/40C into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

24 documented codes
6 most common
2 DIY-safe checks
4 engineer needed

The 6 most common faults

01
<0,6 bar High DIY-safe

Your boiler has lost the water pressure needed to circulate heat, so it has safely shut down to prevent damage.

What to try first

Locate the external filling loop, which is usually a silver braided hose under the boiler.Open the two valves on either end of the hose slowly to allow water into the system.Watch the pressure gauge until the needle reaches the green zone (ideally 1.0 to 1.5 bar).Close both valves tightly and remove the hose if required by your specific installation.

Est. cost
£80-150
Parts
Pressure Relief Valve (PRV), Expansion Vessel, Pressure Sensor
Full guide for <0,6 bar
02
>3,0 bar High DIY-safe

Your boiler's internal water pressure is too high, which can cause internal components to leak or the pressure relief valve to activate.

What to try first

Locate a radiator in your home that is easily accessible.Place a small container and a cloth under the radiator bleed valve.Open the bleed valve slowly to release air and a small amount of water until the pressure gauge on the boiler drops to between 1.0 and 1.5 bar.

Est. cost
£80-150
Parts
Pressure relief valve, Filling loop, Pressure transducer
Full guide for >3,0 bar
03
E030 High Engineer

Your boiler has detected that it is running too hot and has automatically shut itself down to prevent damage.

Est. cost
£120-250
Parts
Limit thermostat, Pump, Diverter valve
Full guide for E030
04
E040 High Engineer

Your boiler has detected that the internal part responsible for pushing out exhaust gases is not spinning correctly, so it has safely shut itself down to prevent any unsafe operation.

Est. cost
£180-300
Parts
Fan assembly, Wiring harness, PCB
Full guide for E040
05
E041 High Engineer

Your boiler has detected that the water pressure is too low or inconsistent to safely provide heating and hot water.

Est. cost
£120-220
Parts
Flow switch, Pressure sensor, Water transducer
Full guide for E041
06
E042 High Engineer

Your boiler is struggling to detect the flow of water because its internal sensor is faulty, which is preventing it from heating your water properly.

Est. cost
£150-250
Parts
Water flow sensor/transducer, Wiring harness
Full guide for E042

on the Vokera Vision Plus 35C/40C

Pressure Relief Valve (PRV)Expansion VesselPressure SensorPressure relief valveFilling loopPressure transducer

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Vokera shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 24-code list for the Vokera Vision Plus 35C/40C