Common problems guide

The most common Vokera Vision System Sgc problems

The faults most likely to send a Vokera Vision System Sgc into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

This model is discontinued. Parts can be harder to source and expensive. If repair costs are mounting, a new A-rated boiler may be the smarter choice.
22 documented codes
6 most common
0 DIY-safe checks
6 engineer needed

The 6 most common faults

01
E030 High Engineer

Your boiler has detected that it is getting too hot and has automatically switched itself off to prevent any damage to the internal components.

Est. cost
£120-250
Parts
Limit thermostat, System pump, System filter
Full guide for E030
02
E040 High Engineer

Your boiler has detected that the internal mechanism responsible for safely clearing exhaust gases is not working, so it has shut down to prevent unsafe operation.

Est. cost
£150-£300
Parts
Fan assembly, Wiring harness, Printed Circuit Board (PCB)
Full guide for E040
03
E041 High Engineer

Your boiler is struggling to detect enough water pressure to operate safely and has shut down to prevent damage.

Est. cost
£120-220
Parts
Water pressure sensor, Pressure transducer
Full guide for E041
04
E042 High Engineer

Your boiler is struggling to detect the flow of water because a sensor inside the unit is not sending the correct signal.

Est. cost
£150-250
Parts
Water flow sensor, Wiring harness
Full guide for E042
05
E077 High Engineer

Your boiler is struggling to detect the movement of water, which means it has stopped heating your home or water to prevent internal damage.

Est. cost
£150-250
Parts
Flow sensor, Wiring harness
Full guide for E077
06
E080 High Engineer

Your boiler has detected that the water inside the system is getting far too hot, so it has shut down to prevent damage to itself.

Est. cost
£150-250
Parts
Flow sensor, NTC thermistor, Pump
Full guide for E080

on the Vokera Vision System Sgc

Limit thermostatSystem pumpSystem filterHeat exchangerFan assemblyWiring harness

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Vokera shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue
See the full 22-code list for the Vokera Vision System Sgc