AL10 High

Vokera AL10 Fault Code

The Vokera AL10 fault code means: your boiler has failed to light or stay lit, which is often caused by a blocked condensate pipe or a sensor detecting a problem with the ignition process.. It appears on 8 Vokera models in our database.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description: Ignition failure/not flame sensed, condense sensor activated

What causes the Vokera AL10 fault?

This fault occurs when the boiler tries to ignite but fails to establish a steady flame, or if the safety sensors detect that the waste water cannot drain away properly. The most common reason is a blockage in the condensate trap or external pipework, which causes water to back up into the heat exchanger and extinguish the burner. It can also be triggered by worn ignition components that can no longer create a strong enough spark to light the gas.

This fault is frequently seen during freezing winter spells, as the external condensate pipe can freeze solid and cause the boiler to shut down for safety.

Typical repair cost £80-250 (including labour)

DIY fix possible

Locate the external plastic condensate pipe and check if it has frozen in cold weather.If frozen, carefully pour warm (not boiling) water over the pipe to melt the ice.Restart the boiler by turning the mode selector switch to 'Reset' and then back to the original position.

Find a Gas Safe engineer

Search the official register for a qualified engineer in your area.