Common problems guide

The most common Vokera Compact problems

The faults most likely to send a Vokera Compact into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

11 documented codes
6 most common
3 DIY-safe checks
3 engineer needed

The 6 most common faults

01
Alarm system water pressure High DIY-safe

Your boiler has stopped working because the water pressure inside the heating system has dropped too low.

What to try first

Locate the filling loop valves underneath your boiler.Open the valves gently to let water into the system while watching the pressure gauge.Stop filling when the needle reaches between 1 and 1.5 bar, then close the valves firmly.Press the reset button on your boiler to clear the fault.

Parts
Pressure relief valve, Filling loop, Pressure sensor
Full guide for Alarm system water pressure
02
Alarm safety shutdown and/or internal fault High DIY-safe

Your boiler has safely shut itself down due to an internal safety fault and needs to be reset.

What to try first

Locate the reset button or turn the mode selector to the reset position.Hold the reset button for about 2 to 5 seconds and release.Wait to see if the boiler fires up normally; do not repeat this more than twice if it keeps failing.

Est. cost
£100-300
Parts
Printed Circuit Board (PCB), Safety sensor, Wiring harness
Full guide for Alarm safety shutdown and/or internal fault
03
Alarm high limit thermostat High Engineer

Your boiler has shut down because the water inside got dangerously hot, which usually points to a blockage in the system or a failing pump.

Est. cost
£150-£350
Parts
High limit thermostat, Circulating pump, Automatic bypass valve
Full guide for Alarm high limit thermostat
04
Fault sensors High Engineer

Your boiler has detected an issue with its internal temperature sensors and has temporarily stopped working for safety.

Est. cost
£100-£200
Parts
NTC thermistor, Temperature sensor, Wiring harness
Full guide for Fault sensors
05
N/A Medium DIY-safe

Your boiler's temperature sensors are detecting a problem and need to be reset.

What to try first

Turn the boiler off and on again using the reset button or power switch.Wait a few minutes to see if the error clears.If the error immediately returns, the internal sensors may be faulty.

Est. cost
£90-180
Parts
NTC thermistor, Temperature sensor
Full guide for N/A
06
Red led fixed Emergency Engineer

Your boiler has stopped working because it is failing to ignite the flame, which often points to a problem with the gas supply or the exhaust venting system.

Est. cost
£120-250
Parts
Ignition electrode, Gas valve, PCB
Full guide for Red led fixed

on the Vokera Compact

Pressure relief valveFilling loopPressure sensorPrinted Circuit Board (PCB)Safety sensorWiring harness

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Vokera shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 11-code list for the Vokera Compact