Vokera Linea Fault codes & diagnostics

9 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Gas Discontinued

The Linea range comes in 3 types

Pick the one you have. The fault codes, GC numbers and manual differ by type.

Each model has its own manual A family spans several manuals, one per model or generation. Pick your model above and its page has the manual its fault codes were read from.

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
2 Emergency 5 High 2 Medium

All 9 documented codes

Tap any card for details

01

Your boiler has failed to ignite because it is not receiving gas or has detected an issue with the internal airflow, meaning you currently have no heating or hot water.

Emergency Engineer only £120-250 Shared across the Linea range

Parts commonly replaced

  • Gas valve
  • Ignition electrode
  • Flue seal

Related codes

02

Your boiler is failing to circulate water properly because it cannot sense the flow it needs to heat your home.

High Engineer only £120-250 Shared across the Linea range

Parts commonly replaced

  • Circulating pump
  • Flow sensor
  • Isolation valves

Related codes

03

Your boiler is struggling to clear air and gases away properly because the exhaust pipe or an internal sensor is blocked with debris.

Emergency Engineer only £120-220 Shared across the Linea range

Parts commonly replaced

  • Venturi
  • Flue assembly seals
  • Fan

Related codes

04

Your boiler has stopped working because the water pressure inside the system has dropped too low.

High DIY-safe £80-150 Shared across the Linea range

What to check first

  1. Locate the external filling loop, usually a silver braided hose under the boiler.
  2. Open the small valve(s) at either end to allow water into the system until the pressure gauge reads between 1.0 and 1.5 bar.
  3. Ensure both valves are fully closed tightly and reset the boiler.

Parts commonly replaced

  • Filling loop
  • Pressure relief valve
  • Expansion vessel

Related codes

05

Your boiler has lost connection to its optional remote control unit, preventing it from receiving temperature commands.

Medium DIY-safe £80-150 Shared across the Linea range

What to check first

  1. Check the batteries in the remote control unit and replace them if needed.
  2. Power cycle the boiler by turning it off and on again at the fused spur.
  3. Check that any wired connections between the remote control and boiler are secure.

Parts commonly replaced

  • Remote control unit (RC05)
  • Wiring harness
  • Printed circuit board (PCB)
06

Your boiler is having trouble measuring the temperature of your hot water, which usually means it will stop producing hot water properly.

Medium Engineer only £90-180 Shared across the Linea range

Parts commonly replaced

  • DHW Thermistor
  • NTC Sensor

Related codes

07

Your boiler is struggling to read its own internal water temperature, so it has shut down to prevent overheating.

High Engineer only £120-200 Shared across the Linea range

Parts commonly replaced

  • Primary NTC Thermistor
  • Wiring harness

Related codes

08

Your boiler has detected that it is running too hot and has automatically shut down to prevent damage.

High Engineer only £120-250 Shared across the Linea range

Parts commonly replaced

  • NTC thermistor
  • Primary heat exchanger
  • Pump
09

Your boiler's internal computer has developed an error and can no longer control the heating system correctly.

High Engineer only £220-450 Shared across the Linea range

Parts commonly replaced

  • Main PCB
  • Wiring harness

Related codes