Common problems guide

The most common Vokera Mynute problems

The faults most likely to send a Vokera Mynute into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

16 documented codes
6 most common
4 DIY-safe checks
2 engineer needed

The 6 most common faults

01
10 High DIY-safe

Your boiler has failed to ignite and cannot produce heat, which could be due to a gas supply issue, a blocked exhaust pipe, or an electrical wiring error.

What to try first

Check if other gas appliances, like a hob, are working to confirm your gas supply is active.Ensure your gas meter has credit and the handle is in the 'on' position.Visually check the outside flue pipe for any obvious obstructions like bird nests or debris.Try resetting the boiler by turning the control knob to the 'Reset' position let it sit for a few seconds.

Est. cost
£100-£250
Parts
Ignition Electrode, Gas Valve, Printed Circuit Board (PCB)
Full guide for 10
02
AL40 High DIY-safe

Your boiler has stopped working because the water pressure inside the heating system has dropped too low to operate safely.

What to try first

Locate the external filling loop, which is usually a silver braided hose connecting two pipes beneath the boiler.Open the valves at both ends of the hose to allow mains water into the system.Watch the pressure gauge on the front of the boiler and close the valves once the needle reaches between 1.0 and 1.5 bar.

Est. cost
£80-120
Parts
Filling loop, Pressure relief valve, Pressure sensor
Full guide for AL40
03
AL41 High DIY-safe

Your boiler has stopped working because the water pressure inside the heating system has dropped too low to operate safely.

What to try first

Locate the external filling loop, which is usually a flexible silver braided hose with one or two valves located underneath the boiler.Open the valves slowly to allow mains water into the system until the pressure gauge on the front of the boiler reads between 1.0 and 1.5 bar.Close the valves tightly to stop the flow and ensure no water is leaking from the connection.

Est. cost
£80-150
Parts
Pressure relief valve, Expansion vessel, Filling loop
Full guide for AL41
04
AL79 High DIY-safe

Your boiler has shut down because the internal water has become too hot or isn't circulating through the system quickly enough.

What to try first

Ensure all radiator valves (TRVs) are turned to the maximum settingCheck that the central heating valves underneath the boiler are fully openCheck the system pressure gauge and top up to 1.5 bar if it is lowTurn the boiler off and back on to attempt a reset

Est. cost
£120-£350
Parts
Circulation pump, NTC Temperature Sensor, Main Heat Exchanger (Descaling)
Full guide for AL79
05
AL10 High Engineer

Your boiler has failed to start because it cannot detect a flame, likely due to a build-up of water or debris in the unit's drainage system.

Est. cost
£120-250
Parts
Condensate trap, Ignition electrode, PCB
Full guide for AL10
06
AL20 High Engineer

Your boiler has detected that it is running too hot and has automatically shut itself down to prevent damage.

Est. cost
£120-250
Parts
Limit thermostat, Overheat sensor, Pump
Full guide for AL20

on the Vokera Mynute

Ignition ElectrodeGas ValvePrinted Circuit Board (PCB)Filling loopPressure relief valvePressure sensor

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Vokera shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 16-code list for the Vokera Mynute