Vokera Sabre 35H Fault codes & diagnostics

20 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

System Natural Gas 35 kW 2019-present

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
3 Emergency 16 High 1 Medium

All 20 documented codes

Tap any card for details

4070

Your boiler has detected that the water is getting too hot too quickly, likely due to a circulation problem or a sensor error.

High Engineer only £120-280

Parts commonly replaced

  • NTC Temperature Sensor
  • Circulation Pump
  • Main Heat Exchanger
AL40

Your boiler has stopped working because the water pressure in the system has dropped too low.

High DIY-safe £0-120

What to check first

  1. Locate the filling loop (the flexible silver hose) underneath or near the boiler.
  2. Slowly open the valves on the filling loop until the pressure gauge on the boiler reaches between 1.0 and 1.5 bar.
  3. Close both valves fully and press the 'Reset' button on the control panel.

Parts commonly replaced

  • Filling loop
  • Expansion vessel
  • Pressure relief valve

Related codes

AL41

Your boiler has detected that the water pressure is too low to operate safely and has shut down to prevent damage.

High DIY-safe £0-120

What to check first

  1. Locate the filling loop (usually a silver flexible hose) underneath or near the boiler.
  2. Open the valves slowly until you hear water entering the system.
  3. Watch the pressure gauge until it reaches between 1 and 1.5 bar, then close the valves tightly.
  4. Turn the selector switch to 'OFF/RESET' for a few seconds and then back to the 'ON' position.

Parts commonly replaced

  • Filling loop
  • Expansion vessel
  • Pressure sensor

Related codes

AL74, AL79

Your boiler has encountered a technical communication or internal sensor error and has stopped working to protect itself.

High DIY-safe £120-280

What to check first

  1. Locate the mode selector switch on the front control panel.
  2. Turn the switch to the 'RESET' position and hold it for a few seconds.
  3. Return the switch to its original position and wait to see if the boiler restarts.

Parts commonly replaced

  • NTC Temperature Sensor
  • Main Printed Circuit Board (PCB)
E10

Your boiler has tried to light several times but cannot confirm that a flame has stayed lit, so it has shut down for safety.

High DIY-safe £100-350

What to check first

  1. Check if other gas appliances, like a hob, are working to confirm gas supply.
  2. Check that your gas meter has credit if you have a pre-payment meter.
  3. Move the mode selector switch to 'OFF/RESET' for a few seconds and then back to 'ON' to attempt a restart.

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed Circuit Board (PCB)
  • Flame sensing lead
E011

Your boiler has detected a flame when there shouldn't be one, or the sensor incorrectly thinks a fire is still burning after the gas has been turned off.

High Engineer only £120-£350

Parts commonly replaced

  • Ionisation probe
  • Gas valve
  • Main PCB

Related codes

E020

Your boiler has shut down because its internal temperature has gotten too high and a safety switch has tripped to prevent damage.

High DIY-safe £90-180

What to check first

  1. Check that all radiator valves are fully open to allow water to flow.
  2. Ensure the boiler pressure is between 1 and 1.5 bar on the pressure gauge.
  3. Wait for the boiler to cool down and try turning the selector switch to 'Reset'.

Parts commonly replaced

  • Overheat Thermostat
  • Circulation Pump
  • Thermistor (NTC Sensor)

Related codes

E030

Your boiler has stopped working because the fan that clears out exhaust fumes is not spinning or communicating correctly with the system.

High Engineer only £180-£350

Parts commonly replaced

  • Fan assembly
  • Main PCB
  • Wiring harness

Related codes

E040

Your boiler has detected that the water pressure is either too low or the sensor that monitors it has stopped working.

High DIY-safe £80-160

What to check first

  1. Locate the filling loop (the flexible silver hose) underneath or near the boiler.
  2. Slowly open the valves until you hear water entering the system.
  3. Close the valves when the pressure gauge on the front of the boiler reaches between 1.0 and 1.5 bar.

Parts commonly replaced

  • Water pressure transducer
  • Expansion vessel recharge

Related codes

E041

Your boiler has detected that the water pressure is too low or a sensor that monitors the water level is failing, preventing the system from heating up.

High DIY-safe £80-180

What to check first

  1. Check the pressure gauge on the front of the boiler; it should be between 1.0 and 1.5 bar.
  2. If the pressure is below 1.0, locate the filling loop (usually a silver braided hose with small taps) under the boiler.
  3. Slowly open the tap(s) until the gauge reaches 1.5 bar, then close them tightly.
  4. Press the Reset button on the boiler control panel to clear the error.

Parts commonly replaced

  • Water pressure transducer
  • Filling loop valve
  • Expansion vessel recharge

Related codes

Showing 11–20 of 20
E042

Your boiler's internal sensor that monitors water pressure has developed a fault, preventing the system from operating safely.

High Engineer only £120-190

Parts commonly replaced

  • Water pressure transducer
  • Wiring harness

Related codes

E058

Your boiler has detected an issue with its incoming electrical power supply, meaning the internal computer cannot function correctly.

High DIY-safe £100-£350

What to check first

  1. Check if there is a local power cut or if other appliances are flickering.
  2. Restart the boiler using the reset dial or power switch.
  3. Ensure the boiler is plugged directly into a wall socket rather than an extension lead.

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • External Voltage Stabiliser
E060

Your boiler's temperature sensor for hot water has stopped working correctly, meaning your taps may only provide cold or lukewarm water.

Medium Engineer only £90-160

Parts commonly replaced

  • DHW NTC Thermistor
  • Wiring harness

Related codes

E065

Your boiler has detected an electrical issue with the part that controls the gas flame size, meaning it cannot heat your water or radiators reliably.

High Engineer only £120-£350

Parts commonly replaced

  • Gas valve modulator
  • Main PCB
  • Wiring harness

Related codes

E077

Your boiler has detected an issue with the sensor that monitors the temperature of the water in your central heating system.

High Engineer only £90-160

Parts commonly replaced

  • NTC Temperature Sensor
  • Wiring Harness
  • Main PCB

Related codes

E080

Your boiler has detected that the water temperature is too high or is not circulating correctly, causing it to shut down for safety.

High DIY-safe £100-220

What to check first

  1. Check that all radiator valves are fully open
  2. Ensure the boiler pressure is between 1.0 and 1.5 bar
  3. Bleed all radiators to remove trapped air which may be blocking circulation

Parts commonly replaced

  • Return NTC thermistor (sensor)
  • Circulation pump
  • Main heat exchanger

Related codes

E085, E094, E095

Your boiler has detected an issue with how it burns gas and has shut down as a safety precaution to prevent dangerous fumes.

Emergency Engineer only £120-350

Parts commonly replaced

  • Gas valve
  • Electrode set
  • Burner gasket
  • Heat exchanger

Related codes

E086

Your boiler has detected that waste gases cannot properly escape through the exhaust pipe, often due to a blockage or a faulty safety sensor.

Emergency Engineer only £120-350

Parts commonly replaced

  • Flue assembly
  • Fan
  • Air pressure switch
  • Main PCB
E090

Your boiler has shut down because the internal exhaust gases have reached a dangerously high temperature, indicating a potential safety risk or a severe internal blockage.

Emergency Engineer only £150-450

Parts commonly replaced

  • Main Heat Exchanger
  • Flue NTC Sensor
  • Burner Insulation Panel

Related codes

E091

Your boiler has detected that the main part responsible for heating your water is becoming blocked or dirty, which is preventing it from working efficiently.

High Engineer only £120-£350

Parts commonly replaced

  • Primary Heat Exchanger
  • Heat Exchanger Seals
  • System Flushing Chemicals

Related codes