Common problems guide

The most common Vokera Unica problems

The faults most likely to send a Vokera Unica into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

19 documented codes
6 most common
3 DIY-safe checks
3 engineer needed

The 6 most common faults

01
A01 High DIY-safe

Your boiler has failed to light because it is not detecting a flame, which means your heating and hot water have temporarily stopped working.

What to try first

Check that your gas supply is turned on and other gas appliances in the house are working.Check if your gas prepayment meter has run out of credit if applicable.Locate the boiler's reset button, hold it down for about 5 seconds, and release to see if the boiler reignites.

Est. cost
£90-250
Parts
Ignition electrode, Gas valve, Printed circuit board (PCB)
Full guide for A01
02
A02 High DIY-safe

Your boiler has shut down because it has gotten too hot, likely due to low water pressure in the system.

What to try first

Check your boiler's pressure gauge to ensure it is between 1 and 1.5 bars.Use the filling loop to top up the water pressure if it is too low.Press the reset button on your boiler once the pressure is corrected.

Est. cost
£90-180
Parts
Limit thermostat, Pressure switch, Circulating pump
Full guide for A02
03
A04 High DIY-safe

Your boiler has stopped working because the water pressure inside the system has dropped too low.

What to try first

Locate the filling loop valves underneath your boiler.Open the valves slowly to allow water into the system until the pressure gauge reads between 1.0 and 1.5 bar.Close the valves tightly and press the reset button on your boiler.

Parts
Filling loop, Pressure relief valve, Pressure sensor
Full guide for A04
04
A03 High Engineer

Your boiler has detected an issue with the internal fan that safely removes combustion gases, so it has locked out to prevent unsafe operation.

Est. cost
£150-£300
Parts
Fan assembly, Printed Circuit Board (PCB)
Full guide for A03
05
A07 High Engineer

Your boiler has temporarily stopped working because it is getting incorrect temperature readings from its internal sensors, meaning it cannot safely regulate the heat.

Est. cost
£120-220
Parts
Flow thermistor, NTC sensor, Wiring harness
Full guide for A07
06
A08 High Engineer

Your boiler has temporarily stopped working because it cannot accurately read the temperature of the water returning from your radiators.

Est. cost
£120-220
Parts
Return thermistor, NTC sensor
Full guide for A08

on the Vokera Unica

Ignition electrodeGas valvePrinted circuit board (PCB)Limit thermostatPressure switchCirculating pump

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Vokera shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 19-code list for the Vokera Unica