Worcester Bosch 6-t5 Fault Code
Also written as 6T5 — same fault.
The Worcester Bosch 6-t5 fault code means: your boiler is stuck in hot water mode, meaning your taps will work but your radiators will fail to heat up.. It appears on 1 Worcester Bosch model in our database.
Technical description: 3-way valve permanently in the DHW heating position: 0: heating, 1: DHW.
DIY fix possible
Turn the boiler power off at the fused spur switch for 30 seconds and turn it back on to reset the valve position.Press the 'Reset' button on the boiler control panel.Ensure your room thermostat is calling for heat to encourage the valve to switch.
Find a Gas Safe engineer
Search the official register for a qualified engineer in your area.
Gas Safe Register →Worcester Bosch models that show the 6-t5 fault code
Click a model for the full fault code list and model-specific repair notes.
Source
Worcester Bosch 6-t5 fault code information on this page is sourced and cross-checked against the official Worcester Bosch service / installation manuals for each affected model.
Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 27 April 2026