E5218 High

Worcester Bosch E5218 Fault Code

The Worcester Bosch E5218 fault code means: your boiler has shut down because the internal water temperature has become too hot, likely due to a lack of water flow or a circulation problem.. It appears on 2 Worcester Bosch models in our database.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description: Flow temperature too high

What causes the Worcester Bosch E5218 fault?

This fault occurs when the water inside the boiler heats up too quickly or reaches an unsafe temperature, forcing the system to shut down for safety. The most common reason is a failure in the circulation pump or a blockage in the pipes, which prevents the hot water from moving away from the burner. It can also be caused by a faulty sensor that is incorrectly reporting the water temperature to the control board.

This issue often appears when the heating is first turned on after summer, as circulation pumps can seize up if they haven't been used for several months.

Typical repair cost £120-350 (including labour)

DIY fix possible

Check if all radiator valves are open to ensure water can flow.Check the boiler pressure gauge and top up to 1.5 bar if it is too low.Restart the boiler using the reset button to see if the fault clears.

Find a Gas Safe engineer

Search the official register for a qualified engineer in your area.

Gas Safe Register →

Worcester Bosch models that show the E5218 fault code

Click a model for the full fault code list and model-specific repair notes.

Source

Worcester Bosch E5218 fault code information on this page is sourced and cross-checked against the official Worcester Bosch service / installation manuals for each affected model.

Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 27 April 2026