FAIL POINT D High

Worcester Bosch FAIL POINT D Fault Code

Also written as FAILPOINTD — same fault.

The Worcester Bosch FAIL POINT D fault code means: your boiler is not receiving a signal from your thermostat or internal timer telling it to turn on.. It appears on 4 Worcester Bosch models in our database.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description: No heat demand. Room thermostat, mains programmer (or link), or electronic programmer at ST5 failure. Red diode may be damaged.

What causes the Worcester Bosch FAIL POINT D fault?

This fault occurs when there is a break in the communication link between your controls and the boiler's main computer. It typically happens because the mechanical timer has worn out or the batteries in your wall thermostat have died, meaning the boiler never receives the 'on' command. In some cases, the internal electronic board that processes these signals has developed a fault and can no longer recognize when heat is being requested.

This issue is frequently seen during the first cold snap of autumn when homeowners try to turn their heating back on after it has been switched off all summer.

Typical repair cost £60-£200 (including labour)

DIY fix possible

Check that your room thermostat is turned up higher than the current room temperature.Replace the batteries in your wireless room thermostat if it has them.Ensure your programmer or timer is set to 'ON' or 'AUTO' and that the clock is showing the correct time.

Find a Gas Safe engineer

Search the official register for a qualified engineer in your area.

Gas Safe Register →

Worcester Bosch models that show the FAIL POINT D fault code

Click a model for the full fault code list and model-specific repair notes.

Source

Worcester Bosch FAIL POINT D fault code information on this page is sourced and cross-checked against the official Worcester Bosch service / installation manuals for each affected model.

Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 27 April 2026