The Worcester Bosch FAIL POINT G Primary Overheat fault code means: your boiler has detected that it is getting dangerously hot and has shut itself down to prevent damage.. It appears on 1 Worcester Bosch model in our database.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description: Primary Overheat. Boiler not fully water pressurised, air in system, pump failure, primary sensor not correctly fixed, or overheat thermostat short circuit across contacts 5 & 6.
Typical repair cost £150-300 (including labour)

DIY fix possible

Check the pressure gauge on the front of the boiler is between 1 and 1.5 bar.If the pressure is low, use the internal filling key to top it up.Ensure all radiator valves are fully open and bleed any trapped air from your radiators.