Worcester Bosch FAILURE AT POINT S Fault Code
Also written as FAILUREATPOINTS — same fault.
The Worcester Bosch FAILURE AT POINT S fault code means: your boiler has detected that dangerous exhaust fumes are not leaving the flue correctly, causing it to overheat and shut down for your safety.. It appears on 1 Worcester Bosch model in our database.
Technical description: Burner fails to shutdown within 2 minutes if the flue is completely blocked when drawing DHW at max. rate, or if the flue spillage sensor temperature exceeds 93°C. Replace flue safety thermostat.
Engineer required
This fault requires a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.
Find a Gas Safe engineer
Search the official register for a qualified engineer in your area.
Gas Safe Register →Worcester Bosch models that show the FAILURE AT POINT S fault code
Click a model for the full fault code list and model-specific repair notes.
Source
Worcester Bosch FAILURE AT POINT S fault code information on this page is sourced and cross-checked against the official Worcester Bosch service / installation manuals for each affected model.
Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 27 April 2026