Safety overheat device tripped High

Worcester Bosch Safety overheat device tripped Fault Code

Also written as SAFETYOVERHEATDEVICETRIPPED — same fault.

The Worcester Bosch Safety overheat device tripped fault code means: your boiler has sensed that the water inside has become dangerously hot and has shut itself down as a safety precaution.. It appears on 1 Worcester Bosch model in our database.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description: All air vented. Water pressure above minimum. Leaks or blockage. Condition and attachment of CH flow sensor. Pump and associated wiring/connections. Connections and wiring to overheat thermostat devices. Otherwise replace control board.
Typical repair cost £120-450 (including labour)

DIY fix possible

Check that your radiator valves are open to allow water to circulateEnsure the system pressure gauge is between 1 and 1.5 barTry to reset the boiler using the reset button on the front panel

Find a Gas Safe engineer

Search the official register for a qualified engineer in your area.

Gas Safe Register →

Worcester Bosch models that show the Safety overheat device tripped fault code

Click a model for the full fault code list and model-specific repair notes.

Source

Worcester Bosch Safety overheat device tripped fault code information on this page is sourced and cross-checked against the official Worcester Bosch service / installation manuals for each affected model.

Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 27 April 2026