Common problems guide

The most common Worcester Bosch Greenstar 25 Si Compact problems

The faults most likely to send a Worcester Bosch Greenstar 25 Si Compact into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

This model is discontinued. Parts can be harder to source and expensive. If repair costs are mounting, a new A-rated boiler may be the smarter choice.
40 documented codes
6 most common
1 DIY-safe checks
5 engineer needed

The 6 most common faults

01
EA High DIY-safe

Your boiler has tried to light several times but has been unable to detect a flame, causing the system to shut down for safety.

What to try first

Check if your gas supply is active by testing other gas appliances like a hobEnsure your gas meter has credit if you use a pre-payment meterPress and hold the 'Reset' button for five seconds to see if the boiler restartsCheck that the condensate pipe (outside white plastic pipe) isn't frozen if the weather is very cold

Est. cost
£100-350
Parts
Ignition Electrode, Flame Sensor (Ionisation Probe), Gas Valve
Full guide for EA
02
F0 High Engineer

Your boiler has temporarily stopped working because it cannot properly read its internal temperature sensors.

Est. cost
£100-250
Parts
NTC Thermistor, Internal Wiring Harness, Printed Circuit Board (PCB)
Full guide for F0
03
C7 High Engineer

Your boiler has stopped working because the internal component responsible for pushing air through the system is failing to start.

Est. cost
£250-450
Parts
Fan unit, Printed Circuit Board (PCB), Wiring harness
Full guide for C7
04
C6 High Engineer

Your boiler's internal fan is spinning faster than it should, which has caused the system to shut down for safety.

Est. cost
£220-450
Parts
Fan assembly, Main Printed Circuit Board (PCB)
Full guide for C6
05
E5 High Engineer

Your boiler has detected that the water inside the system is getting much hotter than it should be, so it has shut itself down to prevent damage.

Est. cost
£150-300
Parts
NTC temperature sensor, Pump, Printed Circuit Board
Full guide for E5
06
E9 High Engineer

Your boiler has temporarily shut down because the internal safety sensor detected that the water temperature has risen too high.

Est. cost
£150-£300
Parts
NTC temperature sensor, High limit safety thermostat, Pump
Full guide for E9

on the Worcester Bosch Greenstar 25 Si Compact

Ignition ElectrodeFlame Sensor (Ionisation Probe)Gas ValvePrinted Circuit Board (PCB)NTC ThermistorInternal Wiring Harness

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Worcester Bosch shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue
See the full 40-code list for the Worcester Bosch Greenstar 25 Si Compact