Common problems guide

The most common Worcester Bosch Greenstar problems

The faults most likely to send a Worcester Bosch Greenstar into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

6 documented codes
6 most common
3 DIY-safe checks
3 engineer needed

The 6 most common faults

01
Slow flash (normally off, flashes on) High DIY-safe

Your boiler has tried to light several times but failed to ignite, so it has safely shut itself down for your protection.

What to try first

Check that your gas supply is turned on and other gas appliances like the hob are working.Check your prepayment gas meter if you have one to ensure you haven't run out of credit.Locate the reset button on your boiler and press it firmly for about 5 seconds to attempt a restart.

Est. cost
£100-£250
Parts
Ignition electrode, Gas valve, PCB
Full guide for Slow flash (normally off, flashes on)
02
Fast flash High Engineer

Your boiler has detected a critical internal error that caused it to shut down for safety reasons and will not restart on its own.

Est. cost
£150-350
Parts
Fan, Printed Circuit Board (PCB), Flue gas sensor
Full guide for Fast flash
03
N/A High Engineer

Your boiler requires a specific installation or commissioning step to be completed before it will unlock and allow normal operation.

Est. cost
£80-150
Full guide for N/A
04
Slow flash (normally on, flashes off) Emergency Engineer

Your boiler has detected that the flue is getting too hot and has automatically shut down to keep your home safe.

Est. cost
£150-300
Parts
Flue thermostat, High limit thermostat, PCB
Full guide for Slow flash (normally on, flashes off)
05
5 pulses Low DIY-safe

Your boiler has been left in its internal testing mode, which is usually only used by engineers during a service or setup.

What to try first

Locate the horizontal dial on the front of the boiler control panel.Check if the dial is turned all the way to the right (maximum position).Turn the dial back to your desired temperature setting to exit service mode.

Est. cost
£0-80
Parts
None
Full guide for 5 pulses
06
2 pulses Low DIY-safe

Your boiler has been left in a manual testing mode after a service or inspection and needs to be switched back to its normal operating setting.

What to try first

Locate the service mode switch (or dial) on the boiler control panel.Ensure the switch is moved from the 'Min' or 'Service' position back to the 'Normal' or 'Off' position.Perform a simple reset by pressing the reset button to clear the flashing light.

Est. cost
£0-80
Full guide for 2 pulses

on the Worcester Bosch Greenstar

Ignition electrodeGas valvePCBFanPrinted Circuit Board (PCB)Flue gas sensor

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Worcester Bosch shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 6-code list for the Worcester Bosch Greenstar