Common problems guide

The most common Alpha SY9 24 problems

The faults most likely to send a Alpha SY9 24 into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

This model is discontinued. Parts can be harder to source and expensive. If repair costs are mounting, a new A-rated boiler may be the smarter choice.
34 documented codes
6 most common
1 DIY-safe checks
5 engineer needed

The 6 most common faults

01
26 High DIY-safe

Your boiler has stopped working because the water pressure inside the heating system has dropped too low.

What to try first

Locate the external filling loop, usually a small silver braided hose with one or two valves underneath the boiler.Open the valve(s) slowly to allow water into the system until the pressure gauge reads between 1.0 and 1.5 bar.Close the valve(s) firmly and ensure no water is leaking from the connection.

Est. cost
£80-120
Parts
Pressure relief valve, Pressure gauge, Expansion vessel
Full guide for 26
02
02 High Engineer

Your boiler is trying to light but cannot successfully ignite the flame to start heating your home.

Est. cost
£120-250
Parts
Ignition electrode, Gas valve, PCB
Full guide for 02
03
05 High Engineer

Your boiler has detected an internal computer error that is preventing it from running safely.

Est. cost
£250-450
Parts
Printed Circuit Board (PCB)
Full guide for 05
04
06 High Engineer

Your boiler has detected an internal computer error that is preventing it from starting up correctly.

Est. cost
£200-400
Parts
Printed Circuit Board (PCB), Wiring harness
Full guide for 06
05
13 High Engineer

Your boiler's main control computer is experiencing an internal error, meaning the system has stopped working to prevent further damage.

Est. cost
£250-450
Parts
Printed Circuit Board (PCB)
Full guide for 13
06
14 High Engineer

Your boiler has detected an internal electronic error within its main control system that is preventing it from operating safely.

Est. cost
£250-450
Parts
Printed Circuit Board (PCB)
Full guide for 14

on the Alpha SY9 24

Pressure relief valvePressure gaugeExpansion vesselIgnition electrodeGas valvePCB

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Alpha shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue
See the full 34-code list for the Alpha SY9 24