Common problems guide

The most common Ariston Clas HE Evo problems

The faults most likely to send a Ariston Clas HE Evo into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

This model is discontinued. Parts can be harder to source and expensive. If repair costs are mounting, a new A-rated boiler may be the smarter choice.
45 documented codes
6 most common
4 DIY-safe checks
2 engineer needed

The 6 most common faults

01
1 03 High DIY-safe

Your boiler is struggling to move water through the system, usually because there is trapped air, a closed valve, or a blockage preventing proper flow.

What to try first

Check all radiator valves in your home are fully openCheck your boiler's pressure gauge and top up the system to between 1.0 and 1.5 bar if lowBleed any radiators that feel cold at the top to release trapped air

Est. cost
£120-250
Parts
Circulation pump, Flow sensor, Primary heat exchanger
Full guide for 1 03
02
1 05 High DIY-safe

Your boiler is struggling to move enough water through your heating system, so it has shut down to prevent overheating.

What to try first

Check that all radiator valves throughout your home are fully open.Verify your heating system pressure gauge is between 1 and 1.5 bar, and top it up using the filling loop if it is too low.Restart the boiler using the reset button.

Est. cost
£120-250
Parts
Circulation pump, Flow sensor, Primary heat exchanger
Full guide for 1 05
03
108 High DIY-safe

Your boiler has detected that the water pressure inside the system has dropped too low to operate safely.

What to try first

Locate the external filling loop, usually found underneath the boilerOpen the filling valve slowly until the pressure gauge on the front panel reads between 1.0 and 1.5 barClose the valve tightly and check the boiler display to see if the fault has cleared

Est. cost
£80-150
Parts
Pressure relief valve, Pressure sensor, Expansion vessel
Full guide for 108
04
1 P2 High DIY-safe

Your boiler has detected that hot water is not flowing around your radiators effectively, causing it to shut down to prevent overheating.

What to try first

Check that all radiator valves throughout your home are fully open.Ensure your system pressure gauge is reading between 1.0 and 1.5 bar.If pressure is low, use the filling loop to top it up to the correct level.

Est. cost
£120-250
Parts
Central heating pump, Flow sensor, System filter
Full guide for 1 P2
05
1 01 High Engineer

Your boiler has detected that it is running too hot and has automatically shut itself down to prevent damage to its internal components.

Est. cost
£120-250
Parts
NTC Sensor, Primary Heat Exchanger, Circulation Pump
Full guide for 1 01
06
1 02 High Engineer

Your boiler is struggling to detect the water pressure inside the system because the sensor that monitors it is faulty or blocked.

Est. cost
£120-220
Parts
Pressure Transducer, Wiring Harness
Full guide for 1 02

on the Ariston Clas HE Evo

Circulation pumpFlow sensorPrimary heat exchangerPressure relief valvePressure sensorExpansion vessel

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Ariston shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue
See the full 45-code list for the Ariston Clas HE Evo