Severity at a glance

Each cell = one fault code. Hover to identify.
1 Emergency 23 High

All 24 documented codes

Tap any card for details

20

Your boiler's temperature sensor for the heating system is not sending a proper signal, causing the boiler to stop working to protect itself.

High Engineer only £120-220 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Central Heating NTC sensor
  • Wiring harness

Related codes

28

Your boiler has detected a problem with the sensor that monitors the temperature of the exhaust gases exiting your home, preventing it from firing safely.

High Engineer only £150-250 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Flue NTC Sensor
  • Wiring Harness

Related codes

40

Your boiler is currently unable to accurately read the temperature of the water returning to it, so it has shut down to prevent potential overheating.

High Engineer only £120-220 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Return NTC thermistor
  • Wiring harness

Related codes

109

Your boiler's computer has encountered an internal error that it does not recognise, causing it to shut down for safety reasons.

High Engineer only £120-250 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

109 R

Your boiler is struggling to move water through the system effectively, which is causing it to shut down to prevent overheating.

High Engineer only £150-350 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Central heating pump
  • System filter
  • Diverter valve

Related codes

110

Your boiler has detected an issue with the temperature sensor that monitors the water heat, causing it to shut down for safety.

High Engineer only £150-250 Shared across the EcoBlue Advance range

Parts commonly replaced

  • NTC Temperature Sensor
  • Wiring harness
  • Printed Circuit Board

Related codes

110 R

Your boiler has detected that it is overheating and has automatically shut down to prevent damage because the internal pump is not moving water correctly.

High Engineer only £150-300 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Central heating pump
  • PCB
  • NTC sensor

Related codes

111

Your boiler has detected an internal error with its main control system that is preventing it from operating correctly.

High Engineer only £150-300 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Printed Circuit Board (PCB)

Related codes

111 R

Your boiler has detected that it is getting too hot and has automatically shut itself down to prevent damage.

High Engineer only £120-250 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Pump
  • Diverter valve
  • Primary heat exchanger
  • System filter

Related codes

117

Your boiler has detected that the water pressure inside your heating system is too high, causing it to shut down for safety.

High DIY-safe £80-150 Shared across the EcoBlue Advance range

What to check first

  1. Locate a radiator in your home, preferably one upstairs.
  2. Use a radiator bleed key to slowly open the bleed valve until a small amount of water drips out.
  3. Collect the excess water with a cloth and close the valve tightly once the pressure gauge on the boiler front panel drops back into the green zone (typically 1.0 to 1.5 bar).

Parts commonly replaced

  • Pressure relief valve
  • Filling loop
  • Expansion vessel

Related codes

Showing 11–20 of 24
118

Your boiler has stopped working because the water pressure inside the heating system has dropped too low.

High DIY-safe £80-150 Shared across the EcoBlue Advance range

What to check first

  1. Locate the external filling loop, which is usually a flexible metal or silver braided hose underneath the boiler.
  2. Open the valves at both ends of the filling loop to let mains water into the system.
  3. Watch the pressure gauge on the front of the boiler until the needle reaches the green zone (typically between 1 and 1.5 bar).
  4. Close both valves tightly and ensure the filling loop is disconnected if it is a temporary type.

Parts commonly replaced

  • Pressure Relief Valve
  • Pressure Sensor
  • Expansion Vessel

Related codes

125

Your boiler is struggling to move water around your heating system effectively, preventing it from heating your home or water properly.

High Engineer only £150-350 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Circulation pump
  • Diverter valve
  • System filter
  • Primary heat exchanger

Related codes

125 R

Your boiler is failing to move hot water around your radiators, likely because the internal pump is blocked, seized, or air is trapped in the system.

High Engineer only £150-350 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Central heating pump
  • Flow sensor
  • System filter

Related codes

128

Your boiler has attempted to start but failed to light the flame, which means it has temporarily stopped working to stay safe.

High Engineer only £120-250 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Ignition lead

Related codes

130

Your boiler has detected that the flue gases are getting too hot, so it has safely shut itself down to prevent any damage.

High Engineer only £150-250 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Flue NTC sensor
  • Primary heat exchanger
  • PCB

Related codes

133

Your boiler has stopped working because it failed to light the flame needed to produce heat.

High Engineer only £150-300 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB

Related codes

133 R

Your boiler is trying to start but cannot detect a flame, likely because the gas supply is blocked or the ignition system has failed.

High Engineer only £150-350 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB

Related codes

151

Your boiler is trying to start but the flame is not catching, so it has shut down as a safety precaution.

High Engineer only £150-300 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB

Related codes

151 R

Your boiler has attempted to light the gas flame multiple times but has failed, so it has safely shut down to prevent gas from escaping.

High Engineer only £150-350 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

160

Your boiler has stopped working because it cannot properly clear exhaust gases, which is a safety mechanism to prevent harmful fumes from building up.

High Engineer only £200-400 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Fan assembly
  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

Showing 21–24 of 24
160 R

Your boiler has detected that the internal fan responsible for safely venting exhaust gases is not working or communicating correctly, so it has shut down to prevent unsafe operation.

High Engineer only £200-350 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Fan assembly
  • Wiring harness
  • PCB

Related codes

321

Your boiler is struggling to accurately measure the temperature of the water used for your taps and shower, which is causing it to stop producing hot water.

High Engineer only £120-220 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Domestic Hot Water (DHW) NTC Thermistor

Related codes

384

Your boiler has detected a flame inside the unit when it should be switched off, so it has shut itself down to ensure your safety.

Emergency Engineer only £150-300 Shared across the EcoBlue Advance range

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Flame Rectification Probe
  • Gas Valve

Related codes

E118

Your boiler has stopped working because the water pressure inside the heating system has dropped too low to operate safely.

High DIY-safe £0-£80 Shared across the EcoBlue Advance range

What to check first

  1. Locate the external filling loop, which is usually a flexible silver hose connecting two pipes underneath the boiler.
  2. Open the small tap or valve on the filling loop to allow cold mains water to enter the system until the pressure gauge reads between 1 and 1.5 bar.
  3. Close the tap firmly to stop the flow and check that the boiler restarts automatically.

Parts commonly replaced

  • Filling loop
  • Pressure relief valve
  • Expansion vessel