Baxi Duo-tec Combi 40 HE A Fault codes & diagnostics

19 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Combi Natural Gas 2008-2015 Discontinued
GC Number 47-075-38
Download the Baxi Duo-tec Combi 40 HE A manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
1 Emergency 18 High

All 19 documented codes

Tap any card for details

20

Your boiler has detected an issue with the sensors that monitor the internal temperature, causing it to stop operating to keep your system safe.

High Engineer only £150-250

Parts commonly replaced

  • NTC Temperature Sensor
  • Wiring harness
  • PCB

Related codes

28

Your boiler is struggling to send water through your radiators or taps because it has detected an issue with the sensor that measures the water temperature as it leaves the unit.

High Engineer only £150-250

Parts commonly replaced

  • NTC sensor
  • Wiring harness

Related codes

50

Your boiler has detected a problem with the temperature sensors, meaning it cannot accurately measure how hot the water is and has stopped working to keep you safe.

High Engineer only £150-250

Parts commonly replaced

  • NTC Temperature Sensor
  • Wiring Harness

Related codes

110

Your boiler has stopped working because it has detected that the water inside it has become dangerously overheated.

High Engineer only £120-250

Parts commonly replaced

  • NTC temperature sensor
  • Primary heat exchanger
  • Pump

Related codes

119

Your boiler has detected that the water pressure inside the system has dropped too low to operate safely.

High DIY-safe £0-£120

What to check first

  1. Locate the external filling loop, which is usually a small silver braided hose with one or two valves located underneath the boiler.
  2. Open the valve(s) slowly to allow mains water into the system until the pressure gauge on the front of the boiler reads between 1.0 and 1.5 bar.
  3. Close the valve(s) tightly and check that the error code clears.

Parts commonly replaced

  • Filling loop
  • Pressure relief valve
  • Pressure sensor

Related codes

125

Your boiler has detected that the water is not circulating properly through the system, often because the water has heated up too quickly or isn't moving away from the internal heat exchanger.

High Engineer only £150-300

Parts commonly replaced

  • Central heating pump
  • System filter
  • Diverter valve

Related codes

130

Your boiler has detected that the temperature of the exhaust gases leaving the flue is too high, causing it to shut down for safety reasons.

High Engineer only £150-300

Parts commonly replaced

  • Flue gas thermostat
  • Primary heat exchanger
  • NTC sensor

Related codes

133

Your boiler has failed to ignite the flame needed to heat your water and has safely shut itself down as a precaution.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

160

Your boiler has detected a problem with the internal fan that pushes exhaust gases out, meaning it has safely shut itself down to prevent unsafe operation.

High Engineer only £150-300

Parts commonly replaced

  • Fan assembly
  • Wiring harness
  • Printed Circuit Board (PCB)

Related codes

E20

Your boiler has lost track of how hot the water inside the heating system is because a temperature sensor has failed.

High Engineer only £90-180

Parts commonly replaced

  • Central Heating NTC Thermistor
  • Wiring harness

Related codes

E28

Your boiler's flue sensor is detecting a fault, meaning the system cannot accurately monitor the temperature of the exhaust gases, so it has safely shut down to prevent damage.

High Engineer only £150-250

Parts commonly replaced

  • Flue NTC Sensor
  • Wiring Harness

Related codes

E50

Your boiler is struggling to detect the temperature of the water it is trying to heat, so it has shut down to prevent overheating.

High Engineer only £120-200

Parts commonly replaced

  • DHW NTC Sensor
  • Wiring harness

Related codes

E110

Your boiler has automatically shut down because it detected that the internal water temperature became dangerously high.

Emergency Engineer only £150-300

Parts commonly replaced

  • Safety Thermostat
  • PCB
  • Automatic Bypass Valve

Related codes

E119

Your boiler has temporarily stopped working because the water pressure inside the system has dropped too low.

High DIY-safe

What to check first

  1. Locate the filling loop under your boiler or near the pipes.
  2. Open the valves slowly to let mains water into the system until the pressure gauge reads between 1 and 1.5 bar.
  3. Close both valves tightly and reset the boiler.

Parts commonly replaced

  • Water pressure switch
  • Pressure relief valve
  • Expansion vessel

Related codes

E125

Your boiler has detected that water is not flowing properly around your heating system, so it has safely shut down to prevent overheating.

High Engineer only £150-350

Parts commonly replaced

  • Central Heating Pump
  • Diverter Valve
  • Flow Sensor

Related codes

E130

Your boiler has temporarily stopped working because it has detected that the exhaust gases coming from the flue are too hot.

High Engineer only £100-£250

Parts commonly replaced

  • Flue NTC sensor
  • Main PCB

Related codes

E133

Your boiler has temporarily stopped working because it cannot detect a steady flame, which usually points to an issue with your gas supply or the way the boiler is igniting.

High Engineer only £100-£250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB

Related codes

E160

Your boiler has stopped working because it cannot detect that the internal fan, which safely removes combustion gases, is operating properly.

High Engineer only £150-£300

Parts commonly replaced

  • Fan Assembly
  • Wiring Harness
  • Printed Circuit Board (PCB)

Related codes

E193

Your boiler is struggling to get water moving around the system correctly before it attempts to fire up.

High Engineer only £150-300

Parts commonly replaced

  • Pump
  • Diverter Valve
  • Flow Switch

Related codes