Biasi Advance Plus 16S ErP Fault codes & diagnostics

22 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

System Natural Gas 2015-present
GC Number 41-583-27
Download the Biasi Advance Plus 16S ErP manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
20 High 2 Medium

All 22 documented codes

Tap any card for details

01E

Your boiler is attempting to start its flame but is failing to do so, meaning you currently have no heating or hot water.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Ignition transformer

Related codes

02E

Your boiler has detected that it is getting too hot and has automatically shut itself down to prevent damage.

High Engineer only £120-250

Parts commonly replaced

  • Safety thermostat
  • System pump
  • Diverter valve
  • Heat exchanger

Related codes

03E

Your boiler has stopped working for safety reasons and requires a professional to identify the internal issue causing the system to shut down.

High Engineer only £120-250

Parts commonly replaced

  • Fan
  • Air pressure switch
  • Control PCB

Related codes

04E

Your boiler has detected that there is not enough water circulating inside it to work safely, so it has shut down to prevent damage.

High DIY-safe £80-180

What to check first

  1. Check the pressure gauge on the front of the boiler; if it is below 1 bar, your system needs topping up.
  2. Locate the external filling loop (or internal key) usually found underneath the boiler.
  3. Slowly open the valve to let water into the system until the gauge reads between 1 and 1.5 bar, then tighten the valve firmly.

Parts commonly replaced

  • Circulation pump
  • Pressure sensor
  • Pressure relief valve

Related codes

05E

Your boiler has detected an issue with the internal ventilation system that prevents it from starting safely.

High Engineer only £180-350

Parts commonly replaced

  • Fan assembly
  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

06E

Your boiler's internal temperature sensor for the heating system is malfunctioning, so the boiler has shut down to prevent overheating.

High Engineer only £120-180

Parts commonly replaced

  • Central Heating NTC Sensor

Related codes

08E

Your boiler is struggling to detect the temperature outside, which may cause it to run inefficiently or stop your heating from adjusting correctly.

Medium Engineer only £100-£200

Parts commonly replaced

  • External NTC temperature sensor
  • Wiring harness to temperature probe

Related codes

09E

Your boiler has detected a faulty sensor that monitors the temperature of the exhaust fumes, meaning the system has shut down to ensure it is operating safely.

High Engineer only £120-220

Parts commonly replaced

  • Flue NTC sensor
  • Wiring harness

Related codes

10E

Your boiler has detected that the temperature of the exhaust gases leaving the unit is too high, so it has safely shut itself down to prevent damage.

High Engineer only £120-250

Parts commonly replaced

  • Flue temperature sensor
  • Primary heat exchanger
  • Printed Circuit Board (PCB)

Related codes

11E

Your boiler has failed to light the flame properly and has shut down for safety reasons.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Ignition lead
  • Printed Circuit Board

Related codes

Showing 11–20 of 22
14E

Your boiler has detected that water is not moving through the system properly, which has caused it to shut down to prevent overheating.

High Engineer only £150-300

Parts commonly replaced

  • Central heating pump
  • NTC sensor
  • Primary flow switch

Related codes

Er 01

Your boiler has tried to light several times but failed, so it has shut itself down for safety.

High DIY-safe £100-280

What to check first

  1. Check if other gas appliances, like your hob, are working to ensure fuel is reaching the house
  2. Ensure your gas meter hasn't run out of credit or been turned off
  3. Press and hold the 'Reset' button for five seconds to see if the boiler restarts

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Flame sensing probe
  • Printed Circuit Board (PCB)

Related codes

Er 02

Your boiler has switched itself off because it has detected that the water inside has become or is becoming too hot.

High DIY-safe £100-280

What to check first

  1. Ensure all radiator valves are fully open to allow water to circulate
  2. Check that the boiler pressure is between 1.0 and 1.5 bar on the gauge
  3. Press and hold the 'Reset' button for five seconds to restart the system

Parts commonly replaced

  • Overheat Thermostat
  • Central Heating Pump
  • Main Heat Exchanger
  • Thermistor (NTC Sensor)

Related codes

Er 03

Your boiler has stopped working as a safety precaution and needs to be reset, but if the issue persists, a professional will need to investigate an internal fault.

High Engineer only £100-250

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Fan
  • Wiring harness

Related codes

Er 04

Your boiler has detected that there is either not enough water in the system or the water isn't moving through the pipes correctly.

High DIY-safe £100-280

What to check first

  1. Check the pressure gauge on the front of the boiler; it should be between 1 and 1.5 bar.
  2. If the pressure is too low, use the filling loop underneath the boiler to top it up with water.
  3. Ensure all radiator valves and isolation valves under the boiler are fully open.

Parts commonly replaced

  • Circulating Pump
  • Water Pressure Switch
  • Flow Temperature Sensor

Related codes

Er 05

Your boiler has detected an issue with the internal air circulation system, which is preventing it from igniting safely.

High Engineer only £180-300

Parts commonly replaced

  • Fan assembly
  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

Er 06

Your boiler is struggling to accurately measure the temperature of the water used for your radiators, which has caused it to stop working to avoid potential damage.

High Engineer only £120-180

Parts commonly replaced

  • Central Heating NTC Temperature Sensor
  • Wiring harness

Related codes

Er 08

Your boiler is struggling because it has lost the signal from an outdoor thermometer that helps it adjust your heating based on the weather.

Medium Engineer only £120-220

Parts commonly replaced

  • External NTC temperature sensor
  • Wiring harness

Related codes

Er 09

Your boiler has detected an issue with the sensor that monitors the exhaust gas temperature, causing it to shut down for safety.

High Engineer only £120-220

Parts commonly replaced

  • Flue gas NTC sensor
  • Wiring harness

Related codes

Er 10

Your boiler has detected that the exhaust gases are becoming too hot, so it has safely shut itself down to prevent damage or overheating.

High Engineer only £150-250

Parts commonly replaced

  • Flue sensor
  • NTC thermistor
  • Primary heat exchanger

Related codes

Showing 21–22 of 22
Er 14

Your boiler has detected that it is dangerously overheating and has automatically shut down to prevent damage.

High Engineer only £150-300

Parts commonly replaced

  • Central heating pump
  • NTC thermistor
  • Printed Circuit Board
Li

Your boiler has temporarily stopped working because the water inside its main heating system has gotten too hot while trying to heat your water.

High Engineer only £150-300

Parts commonly replaced

  • NTC thermistor
  • Automatic bypass valve
  • Circulating pump

Related codes