MAIN BURNER DOES NOT LIGHT High

Chaffoteaux MAIN BURNER DOES NOT LIGHT Fault Code

Also written as MAINBURNERDOESNOTLIGHT — same fault.

The Chaffoteaux MAIN BURNER DOES NOT LIGHT fault code means: your boiler is failing to ignite the main flame, which means you currently have no heating or hot water because the system cannot produce heat safely.. It appears on 3 Chaffoteaux models in our database.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description: I) Gas service tap not open fully; II) Gas pressure low; III) Water rate low; IV) Gas valve not opening; V) Diaphragm punctured; VI) Venturi blocked or loose; VII) Gas control tap faulty; VIII) Wrong injector; IX) Slow ignition device stuck or wrongly adjusted
Typical repair cost £150-350 (including labour)

Engineer required

This fault requires a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.

Find a Gas Safe engineer

Search the official register for a qualified engineer in your area.

Gas Safe Register →

Avoid the next call-out bill

A cover plan would handle faults like MAIN BURNER DOES NOT LIGHT: no call-out fees, no surprise bills.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

Chaffoteaux models that show the MAIN BURNER DOES NOT LIGHT fault code

Click a model for the full fault code list and model-specific repair notes.

Source

Chaffoteaux MAIN BURNER DOES NOT LIGHT fault code information on this page is sourced and cross-checked against the official Chaffoteaux service / installation manuals for each affected model.

Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 7 July 2026