Common problems guide

The most common Chaffoteaux Minima HE System 30 problems

The faults most likely to send a Chaffoteaux Minima HE System 30 into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

This model is discontinued. Parts can be harder to source and expensive. If repair costs are mounting, a new A-rated boiler may be the smarter choice.
34 documented codes
6 most common
2 DIY-safe checks
4 engineer needed

The 6 most common faults

01
E 02 High DIY-safe

Your boiler has stopped working because it cannot move the water around the system effectively.

What to try first

Check your boiler pressure gauge; if it is below 1 bar, use the filling loop to top it up to 1.5 bar.Check if your central heating system is full of air by bleeding your radiators.Ensure all radiator valves are fully open to allow water to flow freely.

Est. cost
£120-250
Parts
Central heating pump, Pressure sensor, Flow switch
Full guide for E 02
02
E 08 High DIY-safe

Your boiler has detected that the water level inside the heating system is too low to operate safely.

What to try first

Locate the external filling loop, which is a silver braided hose connected to two valves under the boiler.Slowly open both valves to allow mains water to enter the system until the pressure gauge on the boiler reads between 1.0 and 1.5 bar.Close both valves tightly and check for any leaks around the filling loop connections.

Est. cost
£80-150
Parts
Pressure gauge, Pressure relief valve, Filling loop
Full guide for E 08
03
A 01 High Engineer

Your boiler has detected that it is running too hot and has automatically shut itself down to prevent damage.

Est. cost
£120-250
Parts
NTC sensor, Circulation pump, Heat exchanger
Full guide for A 01
04
A 03 High Engineer

Your boiler is trying to start but cannot detect a flame, so it has safely shut itself down to prevent gas from building up.

Est. cost
£120-250
Parts
Ignition electrode, Gas valve, PCB
Full guide for A 03
05
A 37 High Engineer

Your boiler's internal computer has encountered a critical error and can no longer process instructions, meaning the unit cannot operate.

Est. cost
£250-450
Parts
Main PCB (Printed Circuit Board)
Full guide for A 37
06
A 39 High Engineer

Your boiler has detected an internal electronic error within its main control brain, preventing it from operating safely.

Est. cost
£250-450
Parts
Main PCB
Full guide for A 39

on the Chaffoteaux Minima HE System 30

Central heating pumpPressure sensorFlow switchPressure gaugePressure relief valveFilling loop

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Chaffoteaux shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue
See the full 34-code list for the Chaffoteaux Minima HE System 30