Ferroli Bluehelix Tech Fault codes & diagnostics

44 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

CombiSystem Natural GasLPG 18-35 kW 2013-2018 Discontinued

Replaced by: Bluehelix R-CRT

Download the Ferroli Bluehelix Tech manual The official installation & service manual (PDF) — the exact document these fault codes were verified against. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
3 Emergency 39 High 1 Medium 1 Low

All 44 documented codes

Tap any card for details

A01

Your boiler has failed to light the flame, which means you currently have no heating or hot water.

High DIY-safe £100-350

What to check first

  1. Check if your gas supply is turned on and other gas appliances are working
  2. Press the 'Reset' button on the boiler control panel for 1 second
  3. Check that your condensate pipe (outside) has not frozen during cold weather

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Ignition lead
  • PCB

Related codes

A02

Your boiler detects a flame when it should be turned off, which prevents the system from starting up safely.

High Engineer only £120-280

Parts commonly replaced

  • Ionisation electrode
  • Main control board
  • Gas valve

Related codes

A05

Your boiler has stopped working because the internal fan, which safely removes waste gases, is not spinning at the correct speed.

High Engineer only £280-450

Parts commonly replaced

  • Fan assembly
  • Main PCB
  • Wiring harness
A06

Your boiler is failing to stay lit after it tries to start up, meaning it cannot provide you with heating or hot water.

High DIY-safe £120-350

What to check first

  1. Check that your gas supply is turned on at the meter
  2. Check if other gas appliances, like a hob, are working correctly
  3. Reset the boiler by pressing the 'Reset' button for 1 second

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Detection electrode

Related codes

A07

Your boiler has shut down because the exhaust fumes have become dangerously hot, which could indicate a blockage or a heat exchanger problem.

Emergency Engineer only £150-550

Parts commonly replaced

  • Heat Exchanger
  • Flue Gas NTC Sensor
  • Main Heat Exchanger Cleaning Kit

Related codes

A08

Your boiler has sensed that parts of the internal system have become too hot, causing it to shut down automatically to prevent damage.

High DIY-safe £120-350

What to check first

  1. Check that your radiator valves are open to allow water to circulate.
  2. Ensure there is enough water pressure in the system (typically 1.0 to 1.5 bar).
  3. Press the 'Reset' button on the control panel to see if the fault clears.

Parts commonly replaced

  • Circulation Pump
  • Heat Exchanger (Cleaning/Descaling)
  • NTC Temperature Sensor

Related codes

A09

Your boiler has sensed it is getting much too hot and has shut itself down to prevent damage or dangerous overheating.

High Engineer only £120-350

Parts commonly replaced

  • Circulation pump
  • Overheated limit thermostat
  • Heat exchanger cleaning

Related codes

A10

Your boiler's internal sensor has stopped correctly monitoring the water temperature as it leaves the unit, preventing it from heating up properly.

High Engineer only £90-180

Parts commonly replaced

  • NTC Flow Sensor
  • Wiring Harness
  • Main PCB

Related codes

A13

Your boiler has detected an issue with the sensor that monitors exhaust gases, causing the system to lock down for safety.

High Engineer only £120-220

Parts commonly replaced

  • Flue Gas Probe (NTC sensor)
  • Wiring Harness
  • Main PCB

Related codes

A14

Your boiler has shut down because it has detected a problem with how the exhaust fumes are being cleared from the property.

Emergency Engineer only £120-350

Parts commonly replaced

  • Pressure switch
  • Fan
  • Flue seals

Related codes

Showing 11–20 of 44
A23

Your boiler has detected that the water inside the heating system is not flowing properly, which has triggered a safety shutdown to prevent the main heat exchanger from overheating.

High Engineer only £150-350

Parts commonly replaced

  • Central heating pump
  • Flow sensor
  • System filter
  • Heat exchanger

Related codes

A24

Your boiler has detected that the heat exchanger is overheating or flow is insufficient, so it has safely shut down to prevent damage.

High Engineer only £150-350

Parts commonly replaced

  • Flow sensor
  • Circulation pump
  • Heat exchanger

Related codes

A26

Your boiler has detected that the water inside the heating system is overheating or not circulating properly, so it has shut down to prevent internal damage.

High Engineer only £150-350

Parts commonly replaced

  • Central heating pump
  • System filter
  • Heat exchanger

Related codes

A42

Your boiler is unable to read the temperature of the water returning from your radiators, so it has stopped working to prevent potential damage.

High Engineer only £120-200

Parts commonly replaced

  • Return NTC sensor
  • Wiring harness

Related codes

A54

Your boiler's internal computer has encountered a critical electronic failure and can no longer control the heating or hot water safely.

High Engineer only £250-£450

Parts commonly replaced

  • Main PCB (Printed Circuit Board)
  • Wiring Loom
A55

Your boiler's internal computer has encountered a critical electronic failure and can no longer control the heating or hot water safely.

High Engineer only £250-£450

Parts commonly replaced

  • Main PCB (Printed Circuit Board)
  • Wiring Loom
A56

Your boiler is failing to light because it cannot detect the flame, likely due to a sensor needing cleaning or replacement.

High Engineer only £120-220

Parts commonly replaced

  • Ignition electrode
  • Ionisation probe
  • Ignition lead

Related codes

A61

Your boiler's internal computer brain has detected a serious electronic failure and can no longer control the heating software correctly.

High Engineer only £300-£550

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Wiring Harness

Related codes

A63

Your boiler's internal computer has encountered a critical electronic failure and can no longer control the heating or hot water safely.

High Engineer only £250-£450

Parts commonly replaced

  • Main PCB (Printed Circuit Board)
  • Wiring Loom
A64

Your boiler has been manually reset too many times in a short period and has now locked itself out for safety.

High Engineer only £100-250

Parts commonly replaced

  • Ignition Electrodes
  • Gas Valve
  • Printed Circuit Board (PCB)

Related codes

Showing 21–30 of 44
A68

Your boiler's internal memory card or control chip is failing to communicate correctly with the main computer board.

High Engineer only £180-350

Parts commonly replaced

  • Boiler Chip Card (BCC)
  • Main PCB (Printed Circuit Board)

Related codes

F08

Your boiler has sensed that parts of the internal system have become too hot, causing it to shut down automatically to prevent damage.

High DIY-safe £120-350

What to check first

  1. Check that your radiator valves are open to allow water to circulate.
  2. Ensure there is enough water pressure in the system (typically 1.0 to 1.5 bar).
  3. Press the 'Reset' button on the control panel to see if the fault clears.

Parts commonly replaced

  • Circulation Pump
  • Heat Exchanger (Cleaning/Descaling)
  • NTC Temperature Sensor

Related codes

F10

Your boiler's internal sensor has stopped correctly monitoring the water temperature as it leaves the unit, preventing it from heating up properly.

High Engineer only £90-180

Parts commonly replaced

  • NTC Flow Sensor
  • Wiring Harness
  • Main PCB

Related codes

F12

Your boiler's hot water sensor has stopped working, meaning the system cannot accurately monitor the temperature of the water coming out of your taps.

Medium Engineer only £90-160

Parts commonly replaced

  • Domestic Hot Water (DHW) NTC Sensor
  • Sensor wiring harness

Related codes

F13

Your boiler has detected an issue with the sensor that monitors exhaust gases, causing the system to lock down for safety.

High Engineer only £120-220

Parts commonly replaced

  • Flue Gas Probe (NTC sensor)
  • Wiring Harness
  • Main PCB

Related codes

F14

Your boiler has shut down because the exhaust fumes have become dangerously hot, which could indicate a blockage or a heat exchanger problem.

Emergency Engineer only £150-550

Parts commonly replaced

  • Heat Exchanger
  • Flue Gas NTC Sensor
  • Main Heat Exchanger Cleaning Kit

Related codes

F15

Your boiler's internal computer is experiencing a software configuration error, preventing it from operating correctly.

High Engineer only £150-350

Parts commonly replaced

  • Main Control PCB
  • Configuration Key

Related codes

F20

Your boiler's computer has detected an internal error in its configuration settings, causing it to stop operating until the software is correctly reset or updated.

High Engineer only £150-300

Parts commonly replaced

  • Main Control PCB
  • Display Interface PCB

Related codes

F21

Your boiler's computer memory has become corrupted or lost its settings, preventing it from knowing how to safely operate.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB
  • Configuration memory chip

Related codes

F34

Your boiler has stopped working because the electrical power supply coming into your home is currently too low for the system to operate safely.

High Engineer only £100-350

Parts commonly replaced

  • Main PCB
  • Power Supply Unit

Related codes

Showing 31–40 of 44
F37

Your boiler has stopped working because the water pressure inside the system is too low.

High DIY-safe £60-120

What to check first

  1. Locate the filling loop (usually a silver flexible hose) under or near the boiler.
  2. Slowly open the valve or valves until you hear water flowing into the system.
  3. Watch the pressure gauge and close the valves once the needle reaches 1.5 bar.

Parts commonly replaced

  • Filling loop
  • Pressure sensor
  • Expansion vessel

Related codes

F39

Your boiler's outside temperature sensor has developed a fault or disconnected, meaning the system may struggle to automatically adjust its heating levels based on the weather.

Low Engineer only £90-160

Parts commonly replaced

  • External weather compensation probe
  • Wiring harness

Related codes

F40

Your boiler's internal computer is experiencing a software configuration error, preventing it from safely starting up your heating or hot water.

High Engineer only £150-300

Parts commonly replaced

  • Main Control PCB
  • Configuration Key

Related codes

F42

Your boiler has detected an unusual temperature difference between its sensors and has shut down to prevent any internal damage.

High Engineer only £120-250

Parts commonly replaced

  • Flow temperature sensor
  • Return temperature sensor
  • Circulation pump

Related codes

F43

Your boiler has shut down to prevent the heat exchanger from overheating, often because the water isn't flowing through the system correctly.

High DIY-safe £120-£450

What to check first

  1. Check that your home heating system pressure is between 1.0 and 1.5 bar
  2. Ensure all radiator valves and isolation valves are fully open
  3. Try resetting the boiler using the 'R' button once the unit has cooled down

Parts commonly replaced

  • Central heating pump
  • Heat exchanger (descaling)
  • Temperature sensor (NTC thermistor)
F47

Your boiler's computer system has detected a configuration error and cannot safely start up, meaning you currently have no heating or hot water.

High Engineer only £150-350

Parts commonly replaced

  • Main Control PCB
  • Wiring harness

Related codes

F50

Your boiler's computer system has detected an internal configuration error, meaning it cannot safely start up or operate until the settings are reset or corrected.

High Engineer only £150-300

Parts commonly replaced

  • Main Control PCB
  • Display Interface Board

Related codes

F51

Your boiler's computer has encountered an internal memory or configuration error that is preventing it from starting up correctly.

High Engineer only £250-400

Parts commonly replaced

  • Main Control PCB
  • Configuration Key

Related codes

F53

Your boiler's computer has encountered a memory or configuration error, meaning it has forgotten its internal instructions and cannot safely operate.

High Engineer only £150-300

Parts commonly replaced

  • Main PCB
  • Control board interface

Related codes

F56

Your boiler is having trouble setting up its gas and air mixture correctly, which prevents it from firing up safely.

High DIY-safe £100-350

What to check first

  1. Check that your gas supply is turned on and other gas appliances are working
  2. Press and hold the 'Reset' button for 5 seconds to clear the fault
  3. Allow the boiler to attempt its automatic calibration sequence for several minutes

Parts commonly replaced

  • Gas valve
  • Ionisation electrode
  • PCB (Control board)
Showing 41–44 of 44
F61

Your boiler's internal computer brain has detected a serious electronic failure and can no longer control the heating software correctly.

High Engineer only £300-£550

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Wiring Harness

Related codes

F66

Your boiler's main control board has detected an internal communication error, meaning it cannot process commands correctly.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB
  • Wiring Harness

Related codes

F67

Your boiler's computer or main control board has experienced a hardware error and cannot communicate with the rest of the system.

High DIY-safe £250-450

What to check first

  1. Locate the electrical spur or plug for the boiler
  2. Switch the power off for at least 30 seconds
  3. Switch the power back on and press the 'Reset' button on the control panel

Parts commonly replaced

  • Main PCB (Printed Circuit Board)
  • Wiring Loom

Related codes

F68

Your boiler's internal memory card or control chip is failing to communicate correctly with the main computer board.

High Engineer only £180-350

Parts commonly replaced

  • Boiler Chip Card (BCC)
  • Main PCB (Printed Circuit Board)

Related codes