Common problems guide

The most common Glow-worm Betacom2 24 problems

The faults most likely to send a Glow-worm Betacom2 24 into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

33 documented codes
6 most common
3 DIY-safe checks
3 engineer needed

The 6 most common faults

01
F22 High DIY-safe

Your boiler has stopped working because the water pressure inside the system has dropped too low to operate safely.

What to try first

Locate the filling loop, which is a silver braided hose with one or two valves located underneath your boiler.Gradually open the valve(s) to let water into the system until the pressure gauge on the front of the boiler reads between 1.0 and 1.5 bar.Close the valve(s) tightly to ensure no water continues to leak into the system.

Est. cost
£80-150
Parts
Filling loop, Pressure relief valve, Expansion vessel
Full guide for F22
02
F24 High DIY-safe

Your boiler is struggling to pump water around your heating system correctly, which is likely due to low system pressure or a blockage.

What to try first

Check your boiler's pressure gauge and ensure it is between 1 and 1.5 bar.If the pressure is below 1 bar, use the filling loop underneath the boiler to top it up to the recommended level.Restart your boiler and check if the fault clears.

Est. cost
£100-250
Parts
Central heating pump, Pressure sensor, Bypass valve
Full guide for F24
03
F29 High DIY-safe

Your boiler was working but the flame has unexpectedly gone out, causing the system to stop for safety.

What to try first

Check if other gas appliances in your home, like a hob, are working to confirm gas supply.If it is freezing outside, check if the white plastic condensate pipe leading outdoors is frozen and thaw it with warm water.Press the reset button (flame symbol with a cross) for five seconds to restart the boiler.

Est. cost
£100-£350
Parts
Ignition Electrode, Gas Valve, Spark Generator
Full guide for F29
04
F28 High Engineer

Your boiler has stopped working because it cannot successfully start up its flame to heat your home.

Est. cost
£150-300
Parts
Electrodes, Gas valve, Printed Circuit Board (PCB)
Full guide for F28
05
F00 High Engineer

Your boiler has lost the ability to accurately measure the temperature of the water circulating through your heating system, so it has shut down to prevent damage.

Est. cost
£120-200
Parts
Flow temperature sensor (NTC thermistor), Wiring harness
Full guide for F00
06
F01 High Engineer

Your boiler has stopped working because a sensor that monitors the temperature of the water returning to the system is reading incorrectly or has disconnected.

Est. cost
£120-200
Parts
Return NTC thermistor, Wiring harness
Full guide for F01

on the Glow-worm Betacom2 24

Filling loopPressure relief valveExpansion vesselCentral heating pumpPressure sensorBypass valve

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Glow-worm shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 33-code list for the Glow-worm Betacom2 24