Common problems guide

The most common Grant Vortex Eco problems

The faults most likely to send a Grant Vortex Eco into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

26 documented codes
6 most common
3 DIY-safe checks
3 engineer needed

The 6 most common faults

01
Burner lock-out High DIY-safe

Your boiler has detected a temporary issue with the burner and has safely shut itself down to prevent any damage.

What to try first

Check your oil tank to ensure you have enough fuel and that the supply valve is openWait 60 seconds for the internal control unit to resetGently press the illuminated red reset button located on the burner once

Est. cost
£120-250
Parts
Photocell, Ignition electrodes, Oil nozzle
Full guide for Burner lock-out
02
Lockout High DIY-safe

Your boiler has stopped working to protect itself and needs a manual reset to try and start up again.

What to try first

Locate the red reset button on the burner control boxPress and hold the button for 3 seconds, then releaseWait to hear if the burner ignites; if it locks out again, do not force further resets

Est. cost
£120-250
Parts
Photocell, Ignition electrodes, Oil burner control box
Full guide for Lockout
03
LOW PRESSURE High DIY-safe

The water pressure inside your heating system has dropped too low, so the boiler has turned itself off to prevent any damage.

What to try first

Locate the external filling loop, which is usually a flexible silver hose connecting two valves near your boiler.Open the valves on both ends of the hose to allow water into the system until the pressure gauge needle reaches between 1.0 and 1.5 bar.Close both valves tightly and remove the hose if required by your specific installation.

Est. cost
£80-150
Parts
Pressure relief valve, Expansion vessel, Pressure switch
Full guide for LOW PRESSURE
04
Lock-out High Engineer

Your boiler has detected a problem with the burner ignition and has safely shut itself down to prevent any issues.

Est. cost
£120-250
Parts
Photocell, Ignition electrodes, Oil pump solenoid coil
Full guide for Lock-out
05
Overheat thermostat High Engineer

Your boiler has switched itself off because it has become dangerously hot, likely due to a circulation problem or a system blockage.

Est. cost
£150-300
Parts
Overheat thermostat, Circulator pump, System filter
Full guide for Overheat thermostat
06
Overheat High Engineer

Your boiler has automatically turned itself off because it has become too hot, which is a safety feature to prevent damage or dangerous conditions.

Est. cost
£150-300
Parts
Overheat thermostat, Circulating pump, PCB
Full guide for Overheat

on the Grant Vortex Eco

PhotocellIgnition electrodesOil nozzleControl boxOil burner control boxOil pump

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Grant shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 26-code list for the Grant Vortex Eco