Common problems guide

The most common Ideal INDEPENDENT COMBI2 problems

The faults most likely to send a Ideal INDEPENDENT COMBI2 into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

29 documented codes
6 most common
2 DIY-safe checks
4 engineer needed

The 6 most common faults

01
F01 High DIY-safe

Your boiler has locked out due to low water pressure in the system, meaning it has temporarily stopped working to protect itself.

What to try first

Locate the filling loop underneath your boiler.Open the valves slowly until the pressure gauge on the front of the boiler rises to between 1.0 and 1.5 bar.Close the valves firmly and press the reset button on the boiler.

Parts
Pressure relief valve, Pressure sensor, Automatic air vent
Full guide for F01
02
L2 High DIY-safe

Your boiler has tried to light five times in a row and failed, so it has safely locked itself off to prevent a build-up of gas.

What to try first

Check if your gas supply is working by testing another gas appliance like a cooker.Check your gas prepayment meter to ensure you have credit if applicable.Press the reset button on your boiler for up to 5 seconds to try restarting the ignition process.

Est. cost
£100-250
Parts
Ignition electrode, Gas valve, PCB
Full guide for L2
03
L01 High Engineer

Your boiler has stopped working safely and is locked out, but the specific reason is shown by the number following the letter 'L' on your display.

Est. cost
£100-250
Parts
Ignition Lead, Gas Valve, Printed Circuit Board
Full guide for L01
04
L 02 High Engineer

Your boiler has failed to light the flame, so it has safely shut itself down to prevent any unburned gas from building up.

Est. cost
£120-250
Parts
Ignition Electrode, Gas Valve, Ignition Lead
Full guide for L 02
05
F 02 High Engineer

Your boiler has lit up but the flame has unexpectedly gone out, causing the system to stop working as a safety precaution.

Est. cost
£150-300
Parts
Ignition electrode, Flame rectification probe, Gas valve
Full guide for F 02
06
F 03 High Engineer

Your boiler has detected an issue with its internal air extraction system, which is preventing it from safely lighting and operating.

Est. cost
£180-350
Parts
Fan assembly, Wiring harness, Printed Circuit Board (PCB)
Full guide for F 03

on the Ideal INDEPENDENT COMBI2

Pressure relief valvePressure sensorAutomatic air ventIgnition electrodeGas valvePCB

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Ideal shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 29-code list for the Ideal INDEPENDENT COMBI2