High
E 36 on Keston C40

Your boiler has lost the signal from the sensor that monitors your heating water temperature, so it has shut down to prevent overheating.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description

Flow thermistor open circuit - check/replace connections/thermistor

Engineer required

This is a high severity fault. Stop using the boiler and call a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.

Find a Gas Safe engineer
Search the official register →

Related fault codes

Related guides you might find useful