Common problems guide

The most common Main boiler problems

The faults we see most often across the Main range — with plain-English causes, what to check first, estimated repair costs, and whether it's a DIY job or needs a Gas Safe engineer. Based on fault-code data across 17 Main boiler models.

87 unique codes
17 models covered
6 DIY-safe (top 8)
8 engineer needed

The most common Main faults

01
6 Green Flashes High DIY-safe

Your boiler is experiencing a communication error or internal electronic fault that is preventing it from running properly.

Why it happens: This fault occurs when the boiler's internal computer, the Printed Circuit Board, loses the ability to send or receive messages from other components. It is often caused by a loose connection in the wiring or a hardware failure within the control board itself. Think of it like a computer crash where the system can no longer tell the boiler how to operate safely.

What to try first

Locate the selector switch on the front of the boiler.Turn the switch to the 'Reset' position and hold it for five seconds.Turn the switch back to the 'On' position and wait for the boiler to restart.

Est. cost
£100-£350
Parts
Printed Circuit Board (PCB), Wiring harness
Full guide for MainEco 6 Green Flashes
02
2 Red Flashes High DIY-safe

Your boiler has become too hot and has shut itself down as a safety precaution to prevent damage.

Why it happens: This fault occurs when the water inside the heat exchanger reaches an unsafe temperature, triggering a safety sensor to cut the power. The most common reasons are a pump failure preventing water from moving through the system or a blockage such as lime scale or sludge restricting the flow. Sometimes, the overheat thermostat itself has simply become faulty and is sending a false signal to the control board.

What to try first

Check that your radiator valves are open and not turned to off or zeroEnsure your system water pressure is between 1 and 1.5 bar on the pressure gaugeTurn the selector switch to the reset position for five seconds and then back to your desired setting

Est. cost
£100-£280
Parts
Overheat Thermostat, Circulating Pump, NTC Temperature Sensor
Full guide for MainEco 2 Red Flashes
03
3 Red Flashes High DIY-safe

Your boiler has tried to light itself several times but cannot create a flame, meaning you will not have any heating or hot water until it is reset or repaired.

Why it happens: This fault occurs when the boiler is unable to detect a steady flame after several attempts to ignite the gas. The most common reasons are a lack of gas supply reaching the unit, worn-out ignition components that can't create a spark, or a dirty internal sensor that cannot tell the boiler the flame is lit.

What to try first

Check that your gas emergency control valve is open and you have credit on your gas meterTurn the selector switch to the 'R' (Reset) position for at least five secondsRelease the switch and see if the boiler initiates a successful ignition sequence

Est. cost
£90-280
Parts
Ignition Electrode, Gas Valve, Flame Sensing Probe
Full guide for MainEco 3 Red Flashes
04
6 Red Flashes High DIY-safe

Your boiler has detected a general internal error, often linked to a small electronic glitch or a sensor that is failing to communicate correctly with the main controls.

Why it happens: This fault occurs when the boiler's internal computer receives conflicting information or loses contact with the main components that manage the heating process. It is typically caused by a communication breakdown between the electronic control board and the sensors, or small electrical fluctuations that disrupt the system's logic. In many cases, it indicates that the 'brain' of the boiler is no longer able to safely coordinate the startup sequence.

What to try first

Locate the reset knob on the front control panelTurn the knob to the 'R' (Reset) position and hold for 5 secondsRelease the knob and wait to see if the error light clears and the boiler restarts

Est. cost
£100-280
Parts
Printed Circuit Board (PCB), Wiring harness, Temperature sensors
Full guide for MainEco 6 Red Flashes
05
4 Red Flashes High Engineer

Your boiler has detected an issue with the ventilation fan, which means it cannot safely clear exhaust fumes and will not ignite.

Why it happens: This fault occurs when the boiler's control system senses that the fan is not spinning at the correct speed to safely expel waste gases. The most common reasons are a mechanical failure of the fan motor itself, a loose connection in the wiring, or a fault on the main circuit board that prevents power from reaching the fan.

Est. cost
£220-450
Parts
Extractor Fan, Fan Wiring Harness, Printed Circuit Board (PCB)
Full guide for MainEco 4 Red Flashes
06
5 Red Flashes High Engineer

Your boiler's internal memory chip has developed a software or connection error, meaning it can no longer remember its correct settings to operate.

Why it happens: This fault occurs when the boiler's internal memory chip fails to communicate with the main control board, similar to a corrupted file on a computer. It is usually caused by a hardware failure within the chip itself or a loose physical connection on the circuit board that prevents the boiler from reading its essential operating instructions. Because the boiler no longer knows its own safety limits or settings, it shuts down immediately as a precaution.

Est. cost
£120-350
Parts
Parameter Storage Unit (PSU) chip, Printed Circuit Board (PCB)
Full guide for MainEco 5 Red Flashes
07
09 High DIY-safe

Your boiler has detected an internal error that has caused it to stop working, and it needs to be restarted to attempt to clear the fault.

What to try first

Locate the 'Reset' button on the boiler control panel.Press and hold the button for 2-3 seconds.Wait a few minutes to see if the boiler ignites and the fault code clears.

Est. cost
£100-250
Parts
Printed Circuit Board (PCB), Wiring harness, Gas valve
Full guide for Eco Compact System 09
08
15 High DIY-safe

Your boiler has lost its connection to the fuel supply, meaning it cannot ignite to produce heat or hot water.

What to try first

Locate the reset button (often marked with a flame icon or the word Reset) on the front control panel.Press and hold the button for 3 to 5 seconds until the display clears.Wait a few minutes to see if the boiler fires up and holds the flame.

Est. cost
£120-200
Parts
Gas valve wiring harness, Gas valve assembly, PCB
Full guide for Combi 24 15

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.