Potterton Air Proving LOCKOUT Fault Code
Also written as AIRPROVINGLOCKOUT — same fault.
The Potterton Air Proving LOCKOUT fault code means: your boiler has stopped working because it cannot confirm that harmful exhaust gases are being safely cleared through the flue pipe.. It appears on 2 Potterton models in our database.
Technical description: Manual Lockout. The APS (Air Pressure Switch) is not maintaining its signal. Has occurred 4 times while burner lit.
What causes the Potterton Air Proving LOCKOUT fault?
This fault occurs when the boiler's internal safety sensor cannot detect a steady flow of air through the system, meaning it isn't sure that exhaust fumes are leaving the house safely. The most common reasons are a failing fan that isn't spinning fast enough, a blockage in the flue pipe, or a perished rubber tube that has stopped the sensor from reading air pressure correctly.
This fault is more common during periods of high winds, which can create back-pressure in the flue and interfere with the air pressure sensor's readings.
Engineer required
This fault requires a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.
Find a Gas Safe engineer
Search the official register for a qualified engineer in your area.
Gas Safe Register →Potterton models that show the Air Proving LOCKOUT fault code
Click a model for the full fault code list and model-specific repair notes.
Source
Potterton Air Proving LOCKOUT fault code information on this page is sourced and cross-checked against the official Potterton service / installation manuals for each affected model.
Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 27 April 2026