High Lockout
A(3) on Potterton Flamingo RS40 RS50

Your boiler is struggling to light because the small pipe that starts the main flame is clogged with dust or debris.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description

Blocked pilot filter

What causes this fault?

This fault occurs when the tiny hole that allows gas to reach the pilot light becomes restricted by a buildup of household dust or soot. Because the pilot flame cannot stay strong enough to heat the safety sensor, the boiler fails to ignite the main burner as a security precaution.

This issue is frequently seen in autumn when boilers are turned on for the first time after being inactive all summer, as settled dust is more likely to cause a blockage.

Engineer required

This is a high severity fault. Stop using the boiler and call a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.

Find a Gas Safe engineer
Search the official register →

Related fault codes

Related guides you might find useful