Common problems guide

The most common Potterton Promax SL 24 Heat ErP problems

The faults most likely to send a Potterton Promax SL 24 Heat ErP into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

7 documented codes
6 most common
0 DIY-safe checks
6 engineer needed

The 6 most common faults

01
FAN LOCKOUT High Engineer

Your boiler has stopped working because the internal fan, which safely exhausts gases, is unable to start or spin at the correct speed.

Why it happens: This fault occurs when the boiler's control board cannot detect the fan spinning at the speed required to safely clear waste gases from the system. The most common physical causes are a buildup of dirt or debris in the fan blades, a complete motor failure, or a loose electrical connection between the fan and the main circuit board.

Est. cost
£280-£450
Parts
Fan Assembly, Main PCB, Wiring Loom
Full guide for FAN LOCKOUT
02
THERMISTOR High Engineer

Your boiler has detected a faulty temperature sensor which means it can no longer accurately monitor how hot the water is getting.

Why it happens: This fault occurs when the internal temperature sensor fails to send a reliable signal to the main control board, often due to internal corrosion or electrical fatigue. Because the boiler can no longer track how hot the water is, it shuts down as a safety precaution to prevent the system from overheating. In some cases, the problem can also be caused by loose or damaged wiring that has broken the connection between the sensor and the brain of the boiler.

Est. cost
£100-180
Parts
NTC Thermistor (Temperature Sensor), Wiring Harness
Full guide for THERMISTOR
03
PCB Fault High Engineer

Your boiler's main electronic control board has failed, which means the system cannot safely operate and has shut down.

Est. cost
£250-£400
Parts
Printed Circuit Board (PCB)
Full guide for PCB Fault
04
DRY-FIRE High Engineer

Your boiler has detected that it is not getting enough water or the water is not flowing through it properly, which usually happens if the system needs topping up.

Est. cost
£150-300
Parts
Central heating pump, Water flow switch, Automatic air vent
Full guide for DRY-FIRE
05
IGNITION LOCKOUT High Engineer

Your boiler has stopped working because it failed to light the flame, which usually means it is not getting gas or there is a temporary safety blockage.

Est. cost
£150-350
Parts
Ignition lead, Spark electrode, Gas valve
Full guide for IGNITION LOCKOUT
06
OVERHEAT LOCKOUT Emergency Engineer

Your boiler has automatically shut down because it has detected that it is getting dangerously hotter than it should be.

Est. cost
£150-300
Parts
Overheat thermostat, NTC thermistor, Combustion chamber seal
Full guide for OVERHEAT LOCKOUT

on the Potterton Promax SL 24 Heat ErP

Fan AssemblyMain PCBWiring LoomNTC Thermistor (Temperature Sensor)Wiring HarnessPrinted Circuit Board (PCB)

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Potterton shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 7-code list for the Potterton Promax SL 24 Heat ErP