Remeha Avanta Plus Fault codes & diagnostics

19 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

CombiSystemRegular Natural GasLPG 18-39 kW 2006-2015 Discontinued

Replaced by: Avanta Ace

Download the Remeha Avanta Plus manual The official installation & service manual (PDF) — the exact document these fault codes were verified against. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
1 Emergency 17 High 1 Low

All 19 documented codes

Tap any card for details

d5

Your boiler is currently taking a short, scheduled break to manage its internal temperature before restarting automatically.

Low Engineer only £80-150

Parts commonly replaced

  • Temperature sensor
  • Pump
  • PCB
é0

Your boiler has detected a problem with its internal temperature sensors, meaning it cannot accurately monitor the water temperature and has shut down as a safety precaution.

High Engineer only £120-£220

Parts commonly replaced

  • Flow temperature NTC sensor
  • Return temperature NTC sensor
  • Wiring harness

Related codes

e1

Your boiler is struggling to ignite or detect a flame, causing the system to stop as a safety precaution.

High DIY-safe £100-£350

What to check first

  1. Check that your gas meter is turned on and other gas appliances like the hob are working.
  2. If you have a prepaid gas meter, verify that you have sufficient credit.
  3. Press and hold the 'Reset' button for two seconds and wait up to three minutes for the venting cycle to complete.

Parts commonly replaced

  • Ignition electrode
  • Flame sensing probe
  • Gas valve

Related codes

é1

Your boiler has detected that the water inside is getting too hot too quickly, usually because there isn't enough water pressure or the water isn't moving through the pipes properly.

High DIY-safe £100-£280

What to check first

  1. Check the pressure gauge on the front of the boiler; if it is below 1.0, top it up using the filling loop.
  2. Ensure all radiator valves are fully open to allow water to circulate.
  3. Bleed your radiators to remove any trapped air that might be blocking the flow.

Parts commonly replaced

  • Circulation pump
  • Flow/Return temperature sensor (NTC)
  • Main heat exchanger (flushing)

Related codes

é2

Your boiler has detected that water is not circulating correctly, often because there is trapped air or the system pressure is too low.

High DIY-safe £100-280

What to check first

  1. Check the pressure gauge and top up to 1.5 bar if it is low
  2. Bleed all radiators to remove trapped air
  3. Ensure all radiator valves and isolation valves are fully open
  4. Reset the boiler using the reset button

Parts commonly replaced

  • Flow/Return temperature sensors
  • Circulation pump
  • Automatic air vent

Related codes

é3

Your boiler has detected an internal electrical safety fault or a problem with how it is grounded, causing it to shut down to prevent damage.

High Engineer only £150-350

Parts commonly replaced

  • Control unit (PCB)
  • Wiring harness
  • Ignition lead

Related codes

é4

Your boiler is failing to light because it cannot detect a flame after several attempts to start up.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Ignition lead

Related codes

é5

Your boiler is failing to light the flame or keep it running, which means it cannot provide you with heating or hot water.

High Engineer only £150-300

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Ionisation probe
  • Printed Circuit Board (PCB)

Related codes

é6

Your boiler is detecting a flame inside the unit even when it has been instructed to switch off, which indicates a serious internal safety issue.

Emergency Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • Printed circuit board (PCB)
  • Ionisation probe

Related codes

é7

Your boiler has detected an internal communication error between its main electrical parts and has shut down for safety.

High Engineer only £180-350

Parts commonly replaced

  • Main control board (PCB)
  • Wiring harness

Related codes

é8

Your boiler has detected that the internal component responsible for pushing air out of the flue is not spinning correctly, which prevents the boiler from firing up safely.

High Engineer only £180-350

Parts commonly replaced

  • Fan assembly
  • Wiring harness
  • Control board

Related codes

é10

Your boiler is struggling to operate because the internal electronics have detected a general communication or system error that is preventing it from firing up.

High DIY-safe £120-250

What to check first

  1. Locate the external filling loop (a silver flexi-hose) beneath the boiler.
  2. Open the valves to allow mains water into the system until the pressure gauge reads between 1.0 and 1.5 bar.
  3. Close both valves tightly to prevent over-pressurizing.

Parts commonly replaced

  • Main Control Board (PCB)
  • Wiring Harness

Related codes

é11

Your boiler has detected that the internal casing is getting too hot, indicating it is struggling to ventilate correctly or is running too hot internally.

High Engineer only £150-350

Parts commonly replaced

  • Fan
  • Air pressure switch
  • Ventilation seals

Related codes

é13

Your boiler has detected an internal communication error and has safely shut itself down to prevent further issues.

High Engineer only £150-300

Parts commonly replaced

  • Control PCB
  • Wiring harness

Related codes

é43

Your boiler has detected that some of its internal settings are outside of the allowed range, preventing it from operating safely.

High Engineer only £120-250

Parts commonly replaced

  • Control board (PCB)
  • Communication cable

Related codes

e44

Your boiler's internal computer has detected an error in its configuration settings and needs a professional to reset internal parameters.

High Engineer only £90-180

Parts commonly replaced

  • Main PCB
  • Parameter Key

Related codes

é44

Your boiler's computer is having trouble reading its own internal settings and needs to be reset or professionally updated to function correctly.

High Engineer only £120-250

Parts commonly replaced

  • Control board (PCB)
  • Parameter chip

Related codes

e45

Your boiler's internal computer has suffered a software failure and can no longer process the settings needed to operate safely.

High Engineer only £280-450

Parts commonly replaced

  • Main PCB (Control Board)
  • Display PCB

Related codes

é45

Your boiler has lost its programmed settings and needs to be reconfigured by a professional to operate correctly.

High Engineer only £100-200

Parts commonly replaced

  • Control board

Related codes

1 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.