Controlled stop: flow set point exceeded by 5°C
Remeha Selecta Fault codes & diagnostics
22 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.
The fault code is already on your display
Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →
Severity at a glance
Each cell = one fault code. Hover to identify.All 22 documented codes
Tap any card for details
External interlock circuit open
Control stop from 3 till 10 minutes; set flow temperature (t1) has already been reached and the heating demand still exists.
Control stop; measured flow temperature (t1) is higher than the flow temperature set (Tset flow).
Shut down; maximum temperature rise is exceeded or if the dT between the supply and return temperature ≥ 45°C or a rate of rise in the flow temperature > 1°C/sec.
Flow or return sensor fault. Short circuit in the flow, return or boiler temperature sensor. Defective or not (properly) connected flow, return or boiler temperature sensor.
E01 Your boiler has detected an internal electronic error and has shut itself down to ensure your home's safety.
Your boiler has detected an internal electronic error and has shut itself down to ensure your home's safety.
Parts commonly replaced
- Control unit
- PCB (Printed Circuit Board)
Related codes
After any error; the 3 minute venting cycle will run first before starting the boiler
After any error; the 3 minute venting cycle will run first before starting the boiler
Control unit or earth fault. Mains supply not correctly earthed. Control unit faulty.
More than 5 start attempts without any flame formation.
No ionisation or ionisation failure more than 5 times during one heat demand.
Unwanted flame formation
After any error; the 3 minute venting cycle will run first before starting the boiler
Fan fault
After any error; the 3 minute venting cycle will run first before starting the boiler
Air box temperature to high
After any error; the 3 minute venting cycle will run first before starting the boiler
Parameter limits
Parameter check
Default parameters
Celcia 20 control override due to frost thermostat call for heat