Remeha Selecta Fault codes & diagnostics

22 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

CombiSystem Natural Gas Discontinued
GC Number 41-288-01
Download the Remeha Selecta manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
1 Emergency 12 High 1 Medium 8 Low

All 22 documented codes

Tap any card for details

8

Your boiler has temporarily paused because the water inside has become slightly hotter than it is supposed to be.

Low Engineer only £90-180

Parts commonly replaced

  • NTC temperature sensor
  • Automatic bypass valve
  • Circulating pump

Related codes

9

Your boiler has temporarily stopped working because a safety device wired into the system, such as a room thermostat or external timer, is signaling that something needs attention.

High Engineer only £90-180

Parts commonly replaced

  • External Thermostat
  • Wiring Centre
  • Time Clock

Related codes

d5

Your boiler has temporarily paused heating because the radiators are already as hot as the temperature you asked for, but it will automatically turn back on in a few minutes once it cools slightly.

Low Engineer only
d8

Your boiler has temporarily stopped because it detected that the water inside is getting hotter than the temperature you have set, likely due to poor circulation.

Medium Engineer only £120-250

Parts commonly replaced

  • Pump
  • Central heating filter
  • System diverter valve

Related codes

d9

Your boiler has switched itself off because the water inside is heating up too quickly or too unevenly, which often happens when water cannot circulate through your radiators properly.

High Engineer only £150-300

Parts commonly replaced

  • Pump
  • Plate heat exchanger
  • Diverter valve

Related codes

é0

Your boiler has detected a problem with its internal temperature sensors, meaning it cannot accurately monitor the water temperature and has shut down as a safety precaution.

High Engineer only £120-£220

Parts commonly replaced

  • Flow temperature NTC sensor
  • Return temperature NTC sensor
  • Wiring harness

Related codes

E01

Your boiler has detected an internal electronic error and has shut itself down to ensure your home's safety.

High Engineer only £250-450

Parts commonly replaced

  • Control unit
  • PCB (Printed Circuit Board)

Related codes

é1

Your boiler is simply running a standard three-minute safety pause to clear trapped air after a previous glitch, and no action is usually needed.

Low DIY-safe

What to check first

  1. Wait for the 3-minute venting cycle to finish automatically
  2. Observe if the boiler restarts normally once the countdown ends
  3. Check that your radiators are properly bled if air keeps building up
é2

Your boiler is just taking a temporary three-minute safety pause to clear out trapped air before it attempts to start up again after a previous hiccup.

Low DIY-safe

What to check first

  1. Wait for the three-minute venting cycle to finish automatically
  2. Check that your radiators do not need bleeding if air is frequently getting into the system
  3. Ensure your system pressure is sitting at the correct level, usually between 1 and 1.5 bar
é3

Your boiler has detected an internal electrical safety fault or a problem with how it is grounded, causing it to shut down to prevent damage.

High Engineer only £150-350

Parts commonly replaced

  • Control unit (PCB)
  • Wiring harness
  • Ignition lead

Related codes

Showing 11–20 of 22
é4

Your boiler has tried to light itself several times but has failed, likely because there is no gas supply or the ignition part is dirty or broken.

High DIY-safe £100-280

What to check first

  1. Check if other gas appliances in your home, like a hob, are working to ensure gas is reaching the property.
  2. If you have a prepayment meter, check that you have remaining credit and the valve is open.
  3. Press the Reset button on the boiler control panel for one to two seconds.

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB (Printed Circuit Board)

Related codes

é5

Your boiler is failing to light the flame or keep it running, which means it cannot provide you with heating or hot water.

High Engineer only £150-300

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Ionisation probe
  • Printed Circuit Board (PCB)

Related codes

é6

Your boiler is detecting a flame inside the unit even when it has been instructed to switch off, which indicates a serious internal safety issue.

Emergency Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • Printed circuit board (PCB)
  • Ionisation probe

Related codes

é8

Your boiler has detected that the internal fan responsible for venting exhaust gases safely is either not spinning or communicating properly, so it has shut down to keep your home safe.

High Engineer only £180-350

Parts commonly replaced

  • Fan assembly
  • Wiring harness
  • Printed Circuit Board (PCB)

Related codes

é10

Your boiler is simply running a standard three-minute safety and air-clearing cycle after a previous minor error before it attempts to turn back on.

Low DIY-safe

What to check first

  1. Wait for three minutes to see if the boiler automatically clears the cycle and fires up normally.
  2. If the boiler remains locked out, turn the power off and on again to reset the system.

Related codes

é11

Your boiler has detected that the internal casing is getting too hot, indicating it is struggling to ventilate correctly or is running too hot internally.

High Engineer only £150-350

Parts commonly replaced

  • Fan
  • Air pressure switch
  • Ventilation seals

Related codes

é43

Your boiler has detected that some of its internal settings have drifted outside of their safe operating limits, and it has stopped working as a precaution.

High Engineer only £120-250

Parts commonly replaced

  • Main PCB

Related codes

é44

Your boiler has detected an internal software or settings error, which is preventing the system from starting up safely.

High Engineer only £120-250

Parts commonly replaced

  • Control board
  • Parameter key

Related codes

Showing 21–22 of 22
é45

Your boiler has lost its programmed settings and needs to be reconfigured by a professional to operate correctly.

High Engineer only £100-200

Parts commonly replaced

  • Control board

Related codes

OT ERROR

Your boiler's wall controller is currently overriding normal settings because the built-in frost protection has kicked in to prevent your pipes from freezing during cold weather.

Low DIY-safe

What to check first

  1. Check if the weather outside is particularly freezing, as this is a normal protective feature.
  2. Wait for the temperature to rise, at which point the message should clear on its own.
  3. Check your Celcia 20 room thermostat settings to ensure the frost protection temperature isn't set too high.