Remeha 28. Fault Code
Also written as 28 — same fault.
The Remeha 28. fault code means: your boiler's fan is not spinning correctly, which means the system cannot safely vent exhaust gases and has shut down as a precaution.. It appears on 2 Remeha models in our database.
Technical description: Fan does not run. Fan defective or improperly fitted (mechanically or electrically). Fuse F2 (3.15 AT) defective. Transformer defective (power on X3?).
Engineer required
This fault requires a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.
Find a Gas Safe engineer
Search the official register for a qualified engineer in your area.
Gas Safe Register →Remeha models that show the 28. fault code
Click a model for the full fault code list and model-specific repair notes.
Source
Remeha 28. fault code information on this page is sourced and cross-checked against the official Remeha service / installation manuals for each affected model.
Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 27 April 2026