Neon 3 on Saunier Duval Xeon 30ff

Your boiler has detected an issue with its internal air supply system, which is preventing it from safely starting up the burner.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description

Is neon 3 lit? NO: Is there 230V~ between "N/C" on air pressure switch and N? NO: Check yellow cable between printed circuit board and air pressure switch. If satisfactory replace printed circuit board.

Engineer required

This is a high severity fault. Stop using the boiler and call a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.