Sime Murelle EV HE System Fault codes & diagnostics

70 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

System Natural Gas 2010-2018 Discontinued

The Murelle EV HE range comes in 5 types

Pick the one you have. The fault codes, GC numbers and manual differ by type.

View the Sime Murelle EV HE System manual Opens the manufacturer's manual on an external site. We're preparing a hosted copy. Open

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
5 Emergency 54 High 9 Medium 2 Low

All 70 documented codes

Tap any card for details

01

Your boiler has detected that it is running too hot and has automatically shut itself down to prevent damage.

High Engineer only £120-250 Shared across the Murelle EV HE range

Parts commonly replaced

  • Safety thermostat
  • NTC thermistor
  • Circulation pump
  • Heat exchanger

Related codes

02

Your boiler has stopped working because the water pressure inside your heating system has dropped too low to operate safely.

High DIY-safe £80-120 Shared across the Murelle EV HE range

What to check first

  1. Locate the external filling loop (a flexible silver hose connecting two pipes near the boiler)
  2. Open the valves at both ends of the hose to allow water into the system
  3. Monitor the pressure gauge on the boiler until it reaches 1.5 bar
  4. Close both valves tightly and remove the hose if required

Parts commonly replaced

  • Filling loop
  • Pressure relief valve
  • Pressure gauge
  • Expansion vessel

Related codes

03

Your boiler has detected that the water pressure in your heating system is currently set too high for safe operation.

Medium DIY-safe £80-120 Shared across the Murelle EV HE range

What to check first

  1. Locate a radiator in your home, preferably one upstairs.
  2. Place a cloth under the radiator bleed valve and use a radiator key to open it slightly.
  3. Release a small amount of water until the boiler pressure gauge drops to the green zone (typically 1.0 to 1.5 bar).
  4. Tighten the bleed valve firmly and check if the error clears.

Parts commonly replaced

  • Pressure relief valve
  • Pressure sensor
  • Expansion vessel

Related codes

04

Your boiler has detected a fault with the sensor responsible for measuring the temperature of your hot water, so it has shut down to prevent incorrect operation.

High Engineer only £120-200 Shared across the Murelle EV HE range

Parts commonly replaced

  • DHW temperature sensor
  • Wiring harness

Related codes

05

Your boiler has stopped working because it is unable to accurately measure the temperature of the water being sent to your radiators.

High Engineer only £120-220 Shared across the Murelle EV HE range

Parts commonly replaced

  • NTC heating sensor
  • Wiring harness

Related codes

06

Your boiler has detected a safety-related issue and has automatically shut itself down to prevent damage or dangerous operation.

High Engineer only £120-250 Shared across the Murelle EV HE range

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB

Related codes

07

Your boiler has detected that the water pressure inside the system is too low to operate safely.

High DIY-safe £80-150 Shared across the Murelle EV HE range

What to check first

  1. Locate the external filling loop, which is usually a flexible silver hose connected to two valves beneath the boiler.
  2. Slowly open the valves to allow water into the system until the pressure gauge reads between 1.0 and 1.5 bar.
  3. Close both valves tightly and ensure the pressure gauge remains steady.

Parts commonly replaced

  • Filling loop
  • Pressure relief valve
  • Pressure sensor

Related codes

08

Your boiler has failed to ignite or stay lit because it cannot detect a flame, so it has safely shut down to prevent gas from escaping.

High Engineer only £120-250 Shared across the Murelle EV HE range

Parts commonly replaced

  • Ignition electrode
  • Flame rectification probe
  • Gas valve
  • PCB

Related codes

09

Your boiler is struggling to push water around your heating system, which is often caused by trapped air, a blockage, or a pump that has stopped working.

High DIY-safe £120-250 Shared across the Murelle EV HE range

What to check first

  1. Check your boiler pressure gauge and top it up to 1.5 bar if it is below 1 bar.
  2. Bleed all radiators in your home to ensure there is no trapped air preventing flow.
  3. Ensure all radiator valves are fully open to allow water to circulate freely.

Parts commonly replaced

  • Circulation pump
  • Flow switch
  • System filter

Related codes

10

Your boiler has detected an issue with a secondary sensor that monitors the temperature of the water or heating circuit, causing it to stop operating to stay safe.

High Engineer only £120-220 Shared across the Murelle EV HE range

Parts commonly replaced

  • NTC sensor
  • Wiring harness
  • PCB

Related codes

Showing 11–20 of 70
13

Your boiler has detected an issue with the sensors that monitor the safety and flow of exhaust gases, so it has shut itself down to prevent any risk.

Emergency Engineer only £150-300 Shared across the Murelle EV HE range

Parts commonly replaced

  • Flue gas sensor
  • Wiring harness
  • PCB

Related codes

14

Your boiler has detected an issue with the sensor that monitors the air and fumes inside the unit, meaning it has safely shut itself down to prevent any risk.

Emergency Engineer only £150-250 Shared across the Murelle EV HE range

Parts commonly replaced

  • Flue gas sensor
  • Wiring harness
  • Control PCB

Related codes

15

Your boiler has detected an issue with the internal ventilation system that removes exhaust gases, and as a safety precaution, it has stopped running to prevent unsafe operation.

High Engineer only £180-350 Shared across the Murelle EV HE range

Parts commonly replaced

  • Fan assembly
  • Venturi
  • PCB

Related codes

20

Your boiler has detected that the water temperature in one of your heating circuits has become dangerously high and has automatically shut down to prevent damage.

High Engineer only £150-300 Shared across the Murelle EV HE range

Parts commonly replaced

  • Safety thermostat
  • Circulating pump
  • Mixing valve

Related codes

21

Your boiler has lost the signal from a sensor responsible for monitoring the temperature in your underfloor or radiator heating zones, which may stop those specific rooms from heating up correctly.

Medium Engineer only £120-220 Shared across the Murelle EV HE range

Parts commonly replaced

  • NTC temperature sensor
  • Wiring harness

Related codes

22

Your boiler has detected that the water temperature in your secondary heating circuit has become too hot, causing it to shut down for safety.

Medium Engineer only £120-250 Shared across the Murelle EV HE range

Parts commonly replaced

  • Safety thermostat
  • Mixing valve actuator
  • System sensor

Related codes

23

Your boiler is having trouble communicating with the secondary heating circuit that controls a specific part of your home, such as an underfloor heating zone.

Medium Engineer only £150-350 Shared across the Murelle EV HE range

Parts commonly replaced

  • Mixed zone control board
  • System sensor
  • Pump interface cable

Related codes

24

Your boiler's solar water heating system is unable to read the temperature from the roof panel, meaning the solar energy collection feature is currently disabled.

Low Engineer only £120-250 Shared across the Murelle EV HE range

Parts commonly replaced

  • Solar collector sensor probe
  • Wiring loom

Related codes

25

Your boiler is having trouble communicating with the temperature sensor linked to your solar water heating system, which may prevent the boiler from correctly using solar energy to heat your water.

Medium Engineer only £120-220 Shared across the Murelle EV HE range

Parts commonly replaced

  • Solar probe sensor
  • Wiring harness

Related codes

26

Your boiler is having trouble communicating with the temperature sensor connected to your solar water heating system, which may prevent the solar panels from working correctly.

Medium Engineer only £120-250 Shared across the Murelle EV HE range

Parts commonly replaced

  • Solar temperature probe
  • Wiring harness

Related codes

Showing 21–30 of 70
27

Your boiler's electronic control system is incorrectly set up to communicate with solar thermal panels that are not currently part of your heating arrangement.

Low Engineer only £90-180 Shared across the Murelle EV HE range

Parts commonly replaced

  • Main PCB

Related codes

28

Your boiler is displaying a communication error because it is struggling to recognise an internal setting or a connected external control accessory.

Medium Engineer only £120-250 Shared across the Murelle EV HE range

Parts commonly replaced

  • Control PCB
  • System control interface

Related codes

29

Your boiler's internal electronic system is failing to communicate correctly between its control modules, meaning the unit cannot safely start.

High Engineer only £150-300 Shared across the Murelle EV HE range

Parts commonly replaced

  • Main Control Board
  • Wiring Harness

Related codes

AL 01

Your boiler has shut down because it detected that exhaust gases are not being cleared away safely through the flue.

Emergency Engineer only £120-250 Shared across the Murelle EV HE range

Parts commonly replaced

  • Flue gas thermostat
  • Flue seals
  • Heat exchanger

Related codes

AL 02

Your boiler has stopped working because the water pressure inside the system has dropped too low and needs topping up.

High DIY-safe £0-120 Shared across the Murelle EV HE range

What to check first

  1. Locate the filling loop (usually a flexible silver hose) underneath or near the boiler.
  2. Slowly open the valve or valves on the loop until you hear water entering the system.
  3. Watch the pressure gauge and close the valves tightly once the needle reaches between 1.0 and 1.2 bar.

Parts commonly replaced

  • Filling loop
  • Pressure sensor
  • Expansion vessel

Related codes

AL 03

Your boiler has detected that there is too much water pressure in the system, which has caused it to shut down for safety.

High DIY-safe £0-120 Shared across the Murelle EV HE range

What to check first

  1. Locate a radiator bleed valve and use a radiator key to carefully release water into a container.
  2. Monitor the boiler pressure gauge until it drops down to approximately 1.2 bar.
  3. Tighten the bleed valve and reset the boiler to clear the fault code.

Parts commonly replaced

  • Filling loop valve
  • Expansion vessel
  • Pressure sensor

Related codes

AL 04

Your boiler has detected a problem with the sensor that monitors hot water temperature, which may lead to no hot water or inconsistent temperatures.

High Engineer only £90-160 Shared across the Murelle EV HE range

Parts commonly replaced

  • Domestic Hot Water (DHW) thermistor
  • NTC temperature sensor
  • Wiring harness

Related codes

AL 05

Your boiler has detected a problem with the internal temperature sensor that monitors water leaving the unit, preventing it from heating your home safely.

High Engineer only £90-160 Shared across the Murelle EV HE range

Parts commonly replaced

  • Central heating flow NTC sensor
  • Wiring harness

Related codes

AL 06

Your boiler is failing to light the flame properly, meaning it cannot heat your home or water.

High DIY-safe £90-280 Shared across the Murelle EV HE range

What to check first

  1. Check that your gas emergency control valve and meter are turned on
  2. Check if other gas appliances in your home, like a hob, are working correctly
  3. Press and hold the 'R' reset button for 2-3 seconds to restart the ignition sequence

Parts commonly replaced

  • Ignition electrode
  • Flame sensing lead
  • Gas valve

Related codes

AL 07

Your boiler has likely overheated, causing a safety sensor to shut it down to prevent damage.

High DIY-safe £100-220 Shared across the Murelle EV HE range

What to check first

  1. Check that all radiator valves are open and not blocked
  2. Bleed all radiators to remove trapped air from the system
  3. Turn the boiler off and back on to attempt a reset once it has cooled down

Parts commonly replaced

  • Safety thermostat (High Limit Stat)
  • Circulation pump
  • Overheat sensor

Related codes

Showing 31–40 of 70
AL 08

Your boiler is struggling to detect the flame it needs to stay lit, which prevents it from heating your home or water.

High Engineer only £120-280 Shared across the Murelle EV HE range

Parts commonly replaced

  • Ignition electrode
  • Ionisation probe
  • PCB (Printed Circuit Board)
  • Gas valve

Related codes

AL 09

Your boiler is not moving water through the pipes correctly, which causes it to shut down to prevent overheating.

High Engineer only £180-£450 Shared across the Murelle EV HE range

Parts commonly replaced

  • Circulation pump
  • Main heat exchanger (flushing/cleaning)
  • Internal system filter

Related codes

AL 10

Your boiler has detected an error with an internal temperature sensor or a setting mismatch, meaning it cannot accurately monitor the water temperature.

High Engineer only £120-220 Shared across the Murelle EV HE range

Parts commonly replaced

  • Auxiliary temperature sensor
  • Wiring harness
  • Main PCB

Related codes

AL 11

Your boiler has detected a communication problem with the part that controls the gas flow, meaning it cannot safely light or manage the flame.

High Engineer only £120-£280 Shared across the Murelle EV HE range

Parts commonly replaced

  • Gas valve modulator coil
  • Gas valve assembly
  • Wiring harness

Related codes

AL 12

Your boiler's computer has been set to the wrong internal configuration mode and cannot operate safely until the settings are corrected.

High Engineer only £80-120 Shared across the Murelle EV HE range

Parts commonly replaced

  • Main PCB (rarely)

Related codes

AL 13

Your boiler has detected that the exhaust gases are too hot or the sensor monitoring them has failed, causing the system to shut down for safety.

High Engineer only £120-£220 Shared across the Murelle EV HE range

Parts commonly replaced

  • Exhaust sensor (smoke probe)
  • Main heat exchanger cleaning
  • Wiring harness

Related codes

AL 14

Your boiler has detected an issue with the sensor that monitors exhaust fumes, causing the system to shut down for safety.

High Engineer only £120-220 Shared across the Murelle EV HE range

Parts commonly replaced

  • Flue gas sensor (smoke probe)
  • Wiring harness

Related codes

AL 15

Your boiler has stopped working because it cannot communicate with the fan that clears away waste gases.

High Engineer only £120-£350 Shared across the Murelle EV HE range

Parts commonly replaced

  • Fan wiring harness
  • Fan motor
  • Printed Circuit Board (PCB)

Related codes

AL 17

Your boiler has detected that its two internal temperature sensors are giving very different readings, causing it to shut down for safety.

High Engineer only £120-220 Shared across the Murelle EV HE range

Parts commonly replaced

  • Heating NTC dual sensor
  • Wiring harness
  • Main PCB

Related codes

AL 18

Your boiler has stopped working because the waste water pipe is backed up or blocked, preventing the unit from draining safely.

High DIY-safe £80-160 Shared across the Murelle EV HE range

What to check first

  1. Check the plastic pipe leading from the boiler to the outside for signs of freezing or ice blockages.
  2. If frozen, pour warm (not boiling) water over the external pipe to melt the ice.
  3. Ensure the internal drainage trap (siphon) isn't visibly clogged with debris if accessible.

Parts commonly replaced

  • Condensate siphon
  • Condensate electrode/sensor
  • Pipe insulation (lagging)

Related codes

Showing 41–50 of 70
AL 28

Your boiler has been manually reset too many times in a short period and has temporarily locked itself for safety.

High DIY-safe £80-250 Shared across the Murelle EV HE range

What to check first

  1. Leave the boiler powered on and untouched for at least one full hour.
  2. Once the hour has passed, the 'AL 28' code should disappear automatically.
  3. Attempt one final reset; if the original fault returns, do not try to reset it again and call a gas safe engineer.

Parts commonly replaced

  • Ignition Electrode
  • Gas Valve
  • PCB

Related codes

AL 30

Your boiler has detected a problem with the internal sensor that measures the temperature of the water returning from your radiators, preventing it from operating correctly.

High Engineer only £90-160 Shared across the Murelle EV HE range

Parts commonly replaced

  • Return temperature sensor (NTC probe)
  • Wiring harness connector

Related codes

AL 37

Your boiler has stopped working because the electricity supply coming into your home has dropped to an unusually low and unsafe voltage.

High DIY-safe £0-120 Shared across the Murelle EV HE range

What to check first

  1. Check if other electrical appliances in your home are flickering or behaving strangely
  2. Switch the boiler off and then back on again to see if the voltage has stabilised
  3. Contact your regional electricity network provider (DNO) to report a power supply issue if the fault persists

Parts commonly replaced

  • None (External power issue)
  • Main Printed Circuit Board (if damaged by surge)

Related codes

AL 38

Your boiler's safety system has detected a potential blockage or problem with the way it releases exhaust gases, causing the unit to shut down for safety.

Emergency Engineer only £120-280 Shared across the Murelle EV HE range

Parts commonly replaced

  • Flue thermostat
  • Fume pressure switch
  • Main PCB

Related codes

AL 40

Your boiler has detected an issue with the electrical power coming into your home and has shut down for safety.

High Engineer only £100-350 Shared across the Murelle EV HE range

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Voltage Stabiliser

Related codes

AL 41

Your boiler has failed to light several times in a row and has locked itself out for safety.

High DIY-safe £120-280 Shared across the Murelle EV HE range

What to check first

  1. Check if other gas appliances (like a hob) are working to ensure gas is reaching the property
  2. Ensure your gas meter has credit if you use a pre-payment meter
  3. Check that the gas isolation valve under the boiler is fully open
  4. Press the Reset button once to see if the boiler restarts

Parts commonly replaced

  • Ignition Electrode
  • Flame Sensing Probe
  • Gas Valve
  • PCB

Related codes

AL 42

Your boiler has detected that one of the control buttons is stuck or the main control board is malfunctioning, preventing you from choosing settings.

High DIY-safe £180-£350 Shared across the Murelle EV HE range

What to check first

  1. Carefully press and release each button on the control panel to ensure none are physically stuck in the 'in' position.
  2. Gently wipe the control panel with a dry cloth to remove any debris or moisture.
  3. Turn the boiler power off at the fused spur switch, wait 30 seconds, and turn it back on to reset the electronics.

Parts commonly replaced

  • Main PCB (Printed Circuit Board)
  • Control Interface / Display Board

Related codes

AL 43

Your boiler is having trouble communicating with your external thermostat or wall controller, which may prevent your heating from turning on.

High DIY-safe £80-220 Shared across the Murelle EV HE range

What to check first

  1. Check that your wall thermostat is powered on and has fresh batteries if applicable
  2. Ensure any wireless receiver plugged into or near the boiler is securely connected
  3. Reset the boiler to see if the communication link restores itself

Parts commonly replaced

  • OpenTherm Thermostat
  • Wiring harness
  • Main PCB

Related codes

AL 44

Your boiler is failing to light because the internal computer and the gas valve are not communicating correctly to create a flame.

High Engineer only £180-450 Shared across the Murelle EV HE range

Parts commonly replaced

  • Gas Valve
  • Printed Circuit Board (PCB)
  • Ignition Electrode

Related codes

AL 56

Your boiler has switched itself off because the temperature difference between the water leaving and returning is too high, which usually means the water isn't flowing through the system correctly.

High DIY-safe £100-£350 Shared across the Murelle EV HE range

What to check first

  1. Check that all radiator valves are fully open
  2. Ensure the boiler pressure gauge is between 1.0 and 1.5 bar
  3. Bleed all radiators to remove trapped air that might be blocking flow
  4. Press the Reset button once the system has cooled down

Parts commonly replaced

  • Circulation Pump
  • Main Heat Exchanger (Cleaning/Descaling)
  • Flow/Return Thermistors

Related codes

Showing 51–60 of 70
AL 57

Your boiler has detected an inconsistency with its temperature sensors and needs to run a self-test to recalibrate how it monitors heat flow.

High DIY-safe £0-120 Shared across the Murelle EV HE range

What to check first

  1. Locate the selector switch on the control panel
  2. Turn the selector to the OFF/RESET position for at least 5 seconds
  3. Turn the selector back to the ON position and wait for the boiler to complete its automatic calibration sequence

Parts commonly replaced

  • No parts usually required
  • Flow Temperature NTC Sensor

Related codes

AL 72

Your boiler has detected that a temperature sensor is not sitting correctly on the main pipe, meaning it cannot accurately monitor the water temperature.

Medium Engineer only £90-160 Shared across the Murelle EV HE range

Parts commonly replaced

  • Delivery NTC Temperature Sensor
  • Sensor retaining clip

Related codes

AL 74

Your boiler has detected a problem with one of its internal temperature sensors, meaning it cannot accurately monitor the heat being sent to your radiators.

High Engineer only £100-180 Shared across the Murelle EV HE range

Parts commonly replaced

  • NTC Delivery Sensor
  • Wiring Harness

Related codes

AL 77

Your boiler has detected an electrical fault with the gas valve control system, preventing it from managing the fuel supply safely.

High Engineer only £180-450 Shared across the Murelle EV HE range

Parts commonly replaced

  • Gas Valve
  • Printed Circuit Board (PCB)
  • Wiring Harness

Related codes

AL 78

Your boiler has detected an electrical issue with the gas control valve, preventing it from safely regulating the fuel needed for the flame.

High Engineer only £180-450 Shared across the Murelle EV HE range

Parts commonly replaced

  • Gas Valve
  • Printed Circuit Board (PCB)
  • Wiring Harness

Related codes

AL 79

Your boiler has detected an internal communication or electronic issue with the gas control valve, preventing it from safely regulating the fuel supply.

High Engineer only £180-450 Shared across the Murelle EV HE range

Parts commonly replaced

  • Gas Valve
  • Printed Circuit Board (PCB)
  • Wiring Loom

Related codes

AL 80

Your boiler has detected an internal communication failure between the control board and the gas valve, meaning it cannot safely manage the fuel flow to stay alight.

High Engineer only £180-450 Shared across the Murelle EV HE range

Parts commonly replaced

  • Gas Valve
  • Main PCB
  • Wiring Loom

Related codes

AL 81

Your boiler has detected an ignition issue caused by a potential blockage in the air or exhaust pipes, preventing it from starting safely.

High Engineer only £120-280 Shared across the Murelle EV HE range

Parts commonly replaced

  • Air pressure switch
  • Flue terminal
  • Gas valve
  • Venture tube

Related codes

AL 82

Your boiler has shut down because it has failed to ignite or maintain a flame several times in a row.

High Engineer only £120-£350 Shared across the Murelle EV HE range

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

AL 83

Your boiler is struggling to burn gas correctly and may restart itself, but it could lead to a full lockout if the issue persists.

Medium Engineer only £100-280 Shared across the Murelle EV HE range

Parts commonly replaced

  • Ignition electrode
  • Detection electrode
  • Gas valve

Related codes

Showing 61–70 of 70
AL 84

Your boiler has detected that the gas supply pressure is too low to operate safely and effectively.

High Engineer only £100-250 Shared across the Murelle EV HE range

Parts commonly replaced

  • Gas Valve
  • Gas Pressure Regulator
  • Gas Filter

Related codes

AL 88

Your boiler's internal computer has detected a technical fault with its own circuitry and has shut down to protect itself.

High Engineer only £280-£450 Shared across the Murelle EV HE range

Parts commonly replaced

  • Main Printed Circuit Board (PCB)

Related codes

AL 89

Your boiler is struggling to maintain a consistent flame, which is likely caused by a dirty sensor or an issue with the air and gas mixture.

High Engineer only £120-£280 Shared across the Murelle EV HE range

Parts commonly replaced

  • Ionisation electrode
  • Air diaphragm
  • Gas valve

Related codes

AL 90

Your boiler is struggling to burn gas correctly and has shut down for safety because it cannot reach the required power level to operate.

High Engineer only £120-350 Shared across the Murelle EV HE range

Parts commonly replaced

  • Ignition/Ionisation electrode
  • Gas valve
  • Air diaphragm
  • Fan assembly

Related codes

AL 92

Your boiler is struggling to get the right mix of air and gas for the flame, which has caused the system to stop working for safety.

High Engineer only £120-280 Shared across the Murelle EV HE range

Parts commonly replaced

  • Ignition/Sensing Electrode
  • Air Pressure Switch Diaphragm
  • Fan

Related codes

AL 93

Your boiler is struggling to burn gas correctly and efficiently, which is preventing it from running at the power level it needs to heat your home.

High Engineer only £120-£350 Shared across the Murelle EV HE range

Parts commonly replaced

  • Gas valve
  • Electrode set
  • Fan
  • Main PCB

Related codes

AL 95

Your boiler is struggling to maintain a steady flame and is shutting down because it thinks the fire has gone out unexpectedly.

High Engineer only £120-280 Shared across the Murelle EV HE range

Parts commonly replaced

  • Ionisation probe
  • Ignition electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

AL 96

Your boiler has shut down because it cannot safely expel exhaust fumes out of the external flue pipe.

Emergency Engineer only £100-250 Shared across the Murelle EV HE range

Parts commonly replaced

  • Flue terminal
  • Flue seals
  • Fan assembly
  • Air pressure switch

Related codes

AL 98

Your boiler's computer brain has encountered a glitch while trying to start up and cannot proceed.

High DIY-safe £250-450 Shared across the Murelle EV HE range

What to check first

  1. Locate the reset button or dial on the front control panel
  2. Press and hold the reset button for 5 seconds
  3. Wait for the boiler to attempt a restart; if the code persists, a professional is required

Parts commonly replaced

  • Main Printed Circuit Board (PCB)

Related codes

AL 99

Your boiler's main internal computer brain has developed a critical fault and is no longer communicating with the rest of the system.

High Engineer only £250-£450 Shared across the Murelle EV HE range

Parts commonly replaced

  • Main PCB (Printed Circuit Board)

Related codes

1 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.