Common problems guide

The most common Sime Murelle HE Regular problems

The faults most likely to send a Sime Murelle HE Regular into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

This model is discontinued. Parts can be harder to source and expensive. If repair costs are mounting, a new A-rated boiler may be the smarter choice.
34 documented codes
6 most common
3 DIY-safe checks
3 engineer needed

The 6 most common faults

01
E8 High DIY-safe

Your boiler's internal water pressure is too low, meaning there is not enough water circulating to heat your home or provide hot water.

What to try first

Locate the external filling loop (a flexible metal or braided hose) connected to your boiler's pipeworkOpen the valves on the filling loop to allow cold mains water to enter the systemMonitor the pressure gauge on the boiler front until it reaches between 1.0 and 1.5 bar, then close the valves tightly

Est. cost
£80-120
Parts
Filling loop, Pressure relief valve, Pressure sensor
Full guide for E8
02
E9 High DIY-safe

Your boiler has detected that the water pressure inside the system has dropped too low for it to operate safely.

What to try first

Locate the external filling loop (a metal braided hose connected to two valves under the boiler)Open both valves slowly until the pressure gauge on the boiler front reads between 1.0 and 1.5 barClose both valves tightly and restart the boiler

Est. cost
£80-120
Parts
Pressure relief valve, Pressure gauge, Expansion vessel
Full guide for E9
03
ALL 02 High DIY-safe

Your boiler has stopped working because the water pressure inside the system has dropped too low to operate safely.

What to try first

Locate the external filling loop, which is a silver braided hose connected between two pipes near your boiler.Open the small valves at both ends of the hose to allow mains water into the system while watching the pressure gauge.Close both valves firmly once the needle on the pressure gauge reaches the green zone, typically between 1.0 and 1.5 bar.

Est. cost
£80-120
Parts
Pressure relief valve, Pressure sensor, Expansion vessel
Full guide for ALL 02
04
E3 High Engineer

Your boiler has detected an issue with the water flow or pressure sensor, causing it to shut down to prevent potential damage to the internal components.

Est. cost
£120-250
Parts
Flow switch, Pressure sensor, Water pump
Full guide for E3
05
E4 High Engineer

Your boiler is failing to detect that the water is circulating properly, which prevents it from safely heating up.

Est. cost
£150-300
Parts
Circulation pump, Flow switch, System filter
Full guide for E4
06
E5 High Engineer

Your boiler has detected an issue with the air supply or exhaust system, preventing it from operating safely.

Est. cost
£150-300
Parts
Air pressure switch, Flue fan, Venturi
Full guide for E5

on the Sime Murelle HE Regular

Filling loopPressure relief valvePressure sensorPressure gaugeExpansion vesselFlow switch

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Sime shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue
See the full 34-code list for the Sime Murelle HE Regular