Sime Murelle Pro HE 25 HO Fault codes & diagnostics

26 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Heat Only Natural Gas 2015-2018 Discontinued
GC Numbers 41-283-4241-283-53
Download the Sime Murelle Pro HE 25 HO manual The official installation & service manual (PDF) — the exact document these fault codes were verified against. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
3 Emergency 20 High 3 Medium

Which version do you have?

The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.

GC number Appliance (register name) Produced
41-283-53 Murelle PRO HE 25 HO ErP 2015–2018

All 26 documented codes

Tap any card for details

AL 01

Your boiler has detected that the exhaust gases are getting too hot or are not escaping correctly, causing the system to shut down for safety.

Emergency Engineer only £120-280

Parts commonly replaced

  • Flue gas thermostat
  • Heat exchanger cleaning
  • Flue seals

Related codes

AL 02

Your boiler has switched itself off because the water pressure inside the system is too low for it to run safely.

High DIY-safe £0-120

What to check first

  1. Locate the filling loop (usually a silver braided hose with small valves underneath the boiler).
  2. Slowly open the valves until you hear water flowing into the system.
  3. Watch the pressure gauge and close the valves tightly once the needle reaches between 1.0 and 1.2 bar.
  4. Reset the boiler using the control knob if the fault code persists.

Parts commonly replaced

  • Filling loop
  • Pressure sensor
  • Expansion vessel recharge

Related codes

AL 03

Your boiler has detected that there is too much water pressure in the system, which can cause the safety valve to leak or the unit to stop working.

Emergency DIY-safe £0-120

What to check first

  1. Locate a radiator bleed valve and use a radiator key to carefully release water into a cloth or container.
  2. Monitor the boiler's pressure gauge until the needle drops to approximately 1.2 bar.
  3. Ensure the filling loop valves are tightly closed to prevent the pressure from rising again.

Parts commonly replaced

  • Filling loop valve
  • Expansion vessel
  • Pressure relief valve

Related codes

AL 04

Your boiler's temperature sensor for hot water is reporting a fault, meaning the system cannot accurately monitor or heat your tap water.

Medium Engineer only £90-160

Parts commonly replaced

  • Domestic Hot Water (DHW) NTC Sensor
  • Sensor Wiring Harness

Related codes

AL 05

Your boiler has detected a problem with the internal temperature sensor that monitors the water leaving the unit, preventing it from heating up correctly.

High Engineer only £90-170

Parts commonly replaced

  • Flow NTC Temperature Sensor
  • Sensor wiring harness

Related codes

AL 06

Your boiler is failing to light the burner, meaning it cannot produce heat or hot water because the fuel isn't igniting.

High DIY-safe £120-350

What to check first

  1. Check if your gas supply is turned on and other gas appliances are working
  2. Check if you have credit on your gas meter
  3. Press the 'Reset' button on the boiler control panel

Parts commonly replaced

  • Ignition electrode
  • Flame sensing electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

AL 07

Your boiler has likely overheated, causing a safety switch to trip and shut the system down to prevent damage.

High DIY-safe £100-220

What to check first

  1. Check that all radiator valves are fully open to allow water flow
  2. Check the system pressure gauge and top up to 1.5 bar if low
  3. Restart the boiler using the reset button/dial
  4. Bleed all radiators to remove trapped air

Parts commonly replaced

  • Safety thermostat (High-limit stat)
  • Circulating pump
  • Overheat sensor (NTC)

Related codes

AL 08

Your boiler is struggling to detect a flame, which prevents it from firing up to provide heating or hot water.

High DIY-safe £120-£280

What to check first

  1. Check that your gas emergency control valve is in the 'on' position
  2. Verify if other gas appliances in your home, such as a hob, are working correctly to rule out a wider gas supply issue
  3. Try resetting the boiler by turning the selector knob to the 'R' position for a few seconds

Parts commonly replaced

  • Ignition electrode
  • Sensing electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

AL 09

Your boiler has stopped working because water is not moving around the system properly, which is preventing the unit from heating up safely.

High DIY-safe £150-£350

What to check first

  1. Check that your system pressure is between 1.0 and 1.5 bar on the pressure gauge.
  2. Ensure all radiator valves and isolation valves under the boiler are fully open.
  3. Gently bleed your radiators to remove any trapped air that might be blocking flow.

Parts commonly replaced

  • Circulation Pump
  • Central Heating Filter
  • Flow Temperature Sensor

Related codes

AL 10

Your boiler has detected an internal sensor issue or a configuration mismatch, which is preventing it from running properly.

High Engineer only £90-180

Parts commonly replaced

  • Auxiliary NTC Sensor
  • Wiring Harness
  • Main PCB

Related codes

Showing 11–20 of 26
AL 11

Your boiler is unable to control its heat output correctly because a signal wire to the gas burner is broken or detached, causing the system to stop working as a safety precaution.

High Engineer only £90-220

Parts commonly replaced

  • Gas valve modulator coil
  • Wiring harness
  • Gas valve assembly

Related codes

AL 12

Your boiler has lost its connection to the component that controls the gas flow, meaning it cannot safely ignite or heat your home.

High Engineer only £120-220

Parts commonly replaced

  • Gas valve
  • Wiring harness

Related codes

AL 13

Your boiler has detected that the exhaust gases are too hot or the temperature sensor itself has failed, causing the system to shut down for safety.

High Engineer only £120-£220

Parts commonly replaced

  • Exhaust sensor (Smoke probe)
  • Main heat exchanger cleaning
  • Wiring harness

Related codes

AL 14

Your boiler has detected a problem with the sensor that monitors exhaust gases, and it has shut down for safety purposes.

High Engineer only £120-£200

Parts commonly replaced

  • Exhaust sensor (Smoke Probe)
  • Wiring harness

Related codes

AL 15

Your boiler has detected a communication problem with the fan, which means it cannot safely clear waste gases to start the ignition process.

High Engineer only £120-350

Parts commonly replaced

  • Fan wiring harness
  • Fan assembly
  • Main PCB

Related codes

AL 18

Your boiler has detected that waste water cannot drain away properly, usually due to a blocked or frozen pipe outside.

High DIY-safe £80-160

What to check first

  1. Check the plastic pipe leading from the boiler to the outside drain for signs of ice or debris.
  2. Thaw any frozen sections of the external pipe using a hot water bottle or a cloth soaked in warm water.
  3. Ensure the internal trap or siphon is clear of debris if it is accessible without opening the sealed boiler casing.

Parts commonly replaced

  • Condensate siphon
  • Condensate electrode
  • Drain pipework

Related codes

AL 28

Your boiler has locked you out because it was reset too many times in a row while trying to clear a persistent fault.

Medium DIY-safe £80-250

What to check first

  1. Wait for 60 minutes without pressing any buttons to allow the lockout timer to expire.
  2. Ensure the system pressure is between 1 and 1.5 bar on the pressure gauge.
  3. Attempt one single reset of the boiler after the hour has passed.

Parts commonly replaced

  • Ignition Electrode
  • Gas Valve
  • Printed Circuit Board (PCB)

Related codes

AL 37

Your boiler has detected that the electricity supply coming into your home is at a dangerously low voltage, preventing it from running safely.

High Engineer only £0-120

Parts commonly replaced

  • Main PCB
  • Voltage regulator

Related codes

AL 40

Your boiler has detected an issue with the electrical power supply frequency coming into your home and has shut down as a safety precaution.

High Engineer only £100-£350

Parts commonly replaced

  • Main PCB (Printed Circuit Board)
  • Power supply filter

Related codes

AL 41

Your boiler has tried to light several times but cannot maintain a steady flame, causing the system to lock out for safety.

High DIY-safe £100-£250

What to check first

  1. Check that your gas emergency control valve is in the 'on' position
  2. If you have a pre-payment meter, ensure you have sufficient credit
  3. Check if other gas appliances in your home, such as a hob, are working correctly
  4. Reset the boiler by turning the selector switch to the reset position for a few seconds

Parts commonly replaced

  • Ignition electrode
  • Flame sensing electrode
  • Gas valve
  • PCB

Related codes

Showing 21–26 of 26
AL 42

Your boiler has detected that one of its control buttons is stuck or pressed for too long, preventing the system from working correctly.

High DIY-safe £120-350

What to check first

  1. Check all buttons on the front panel to see if any are stuck in the pressed position.
  2. Gently press and release each button several times to ensure they click and move freely.
  3. Try to reset the boiler by holding the reset button for 5 seconds.

Parts commonly replaced

  • Control Interface/Bezel
  • Printed Circuit Board (PCB)

Related codes

AL 43

Your boiler is having trouble communicating with your external thermostat or smart heating controller.

High DIY-safe £80-180

What to check first

  1. Check if your thermostat or remote control has power or fresh batteries.
  2. Ensure the thermostat is properly docked or plugged into its base.
  3. Try resetting the boiler by turning it off and back on at the fused spur switch.

Parts commonly replaced

  • OpenTherm Gateway
  • Smart Thermostat
  • Communication wiring

Related codes

AL 72

Your boiler has detected that a temperature sensor is loose or isn't seated correctly against the internal pipework, causing it to read temperatures inaccurately.

Medium Engineer only £90-160

Parts commonly replaced

  • CH Flow NTC Sensor
  • Sensor retaining clip

Related codes

AL 81

Your boiler has detected a flame at the wrong time during start-up, which usually means there is a problem with the air supply or the gas settings.

High Engineer only £100-250

Parts commonly replaced

  • Air diaphragm
  • Flue seals
  • Gas valve
  • Electrode

Related codes

AL 83

Your boiler is struggling to burn gas correctly, which is often caused by a temporary interruption in the fuel supply or an issue with the ignition system.

High Engineer only £100-280

Parts commonly replaced

  • Ignition electrode
  • Flame sensing electrode
  • Gas valve

Related codes

AL 96

Your boiler has shut down because it cannot safely expel waste gases through the flue pipe, often due to an external blockage or a buildup of debris.

Emergency Engineer only £100-250

Parts commonly replaced

  • Flue seals
  • Fan assembly
  • Air pressure switch

Related codes

1 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.