Vaillant ecoFIT sustain 825 Fault codes & diagnostics

40 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Combi Gas 2016-present
GC Number 47-044-71
Download the Vaillant ecoFIT sustain 825 manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
5 Emergency 32 High 3 Medium

Which version do you have?

The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.

GC number Appliance (register name) Produced
47-044-71 ecoFIT sustain 825 VUW 256/6-3 (H-GB) 2016–present

Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.

All 40 documented codes

Tap any card for details

Connection

Your boiler has lost its ability to talk to its display panel, meaning it doesn't know what you are asking it to do.

High Engineer only £150-350

Parts commonly replaced

  • User interface display board
  • Main PCB
  • Wiring harness

Related codes

F.00

Your boiler has temporarily stopped working because it cannot accurately measure the temperature of the water leaving the system.

High Engineer only £120-220

Parts commonly replaced

  • Flow temperature sensor
  • Wiring harness

Related codes

F.01

Your boiler has temporarily stopped working because it cannot accurately measure the temperature of the water returning from your radiators.

Medium Engineer only £90-180

Parts commonly replaced

  • Return temperature sensor
  • Wiring harness

Related codes

F.10

Your boiler has temporarily stopped working because it has detected an electrical fault with one of its internal temperature sensors.

High Engineer only £90-180

Parts commonly replaced

  • Flow temperature sensor
  • Wiring harness

Related codes

F.11

Your boiler has temporarily stopped working because it has detected an electrical fault with one of its internal temperature sensors.

High Engineer only £90-180

Parts commonly replaced

  • Return temperature sensor
  • Wiring harness

Related codes

F.13

Your boiler has detected a faulty electrical signal from the hot water temperature sensor, meaning it cannot properly monitor the temperature of your hot water.

Medium Engineer only £90-180

Parts commonly replaced

  • NTC temperature sensor
  • Wiring harness

Related codes

F.20

Your boiler has temporarily shut down because the internal water temperature got too high.

High Engineer only £150-300

Parts commonly replaced

  • NTC temperature sensor
  • Circulation pump
  • Main heat exchanger

Related codes

F.22

Your boiler has temporarily stopped working because it has detected a dangerously low level of water pressure inside the system.

High DIY-safe

What to check first

  1. Locate the filling loop underneath your boiler or check the integrated filling key.
  2. Open the valves slowly to let water into the system until the pressure gauge on the front reaches between 1.0 and 1.5 bar.
  3. Close both valves tightly and reset the boiler.

Parts commonly replaced

  • Pressure sensor
  • Filling loop valve
  • Expansion vessel

Related codes

F.23

Your boiler has shut down because there is a dangerous difference in temperature between its internal sensors, usually caused by a restriction in water flow.

High Engineer only £150-£350

Parts commonly replaced

  • NTC temperature sensors
  • Plate heat exchanger
  • Heating pump

Related codes

F.24

Your boiler is temporarily shutting down because the water inside is heating up much faster than normal, usually due to poor water flow.

High Engineer only £150-300

Parts commonly replaced

  • Pump
  • Heat exchanger
  • NTC thermistor

Related codes

Showing 11–20 of 40
F.25

Your boiler has temporarily shut itself down because the exhaust gas coming out of the flue is getting dangerously hot.

Emergency Engineer only £150-350

Parts commonly replaced

  • NTC temperature sensor
  • Main heat exchanger
  • Printed Circuit Board (PCB)

Related codes

F.27

Your boiler has temporarily shut down because it cannot reliably detect the flame inside, meaning it is currently unsafe for it to keep running.

Emergency Engineer only £120-250

Parts commonly replaced

  • Flame electrode
  • Ignition lead
  • Main printed circuit board (PCB)

Related codes

F.28

Your boiler is failing to light the flame needed to produce heat or hot water.

High Engineer only £150-350

Parts commonly replaced

  • Ignition lead
  • Ignition electrode
  • Gas valve
  • Printed Circuit Board

Related codes

F.29

Your boiler is failing to stay lit, which means it has safely shut itself down because it cannot consistently produce or hold a flame.

High Engineer only £150-350

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed Circuit Board (PCB)
  • Flame rectification probe

Related codes

F.32

Your boiler has detected that the fan, which pushes waste gases outside, isn't spinning at the correct speed to ensure safe operation.

High Engineer only £150-350

Parts commonly replaced

  • Fan unit
  • Printed Circuit Board (PCB)
  • Wiring harness
F.49

Your boiler's communication system is experiencing a power supply issue, causing it to lose its ability to talk to your thermostat or internal components.

High Engineer only £120-250

Parts commonly replaced

  • eBUS PCB
  • Wiring harness
  • External thermostat/controller

Related codes

F.61

Your boiler has detected an issue with the control system that regulates the flow of gas into the unit.

Emergency Engineer only £150-350

Parts commonly replaced

  • Gas valve
  • Main printed circuit board (PCB)

Related codes

F.62

Your boiler has detected an issue with the internal safety mechanism that controls the gas flow, so it has safely shut itself down to prevent operation.

High Engineer only £250-450

Parts commonly replaced

  • Gas valve
  • Main printed circuit board (PCB)

Related codes

F.63

Your boiler's internal computer has encountered a memory error and cannot read the essential configuration data required to operate safely.

High Engineer only £300-600

Parts commonly replaced

  • Main PCB
  • Display PCB

Related codes

F.64

Your boiler's main computer control panel is failing to process signals from its sensors, meaning it cannot safely operate the system.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB
  • Wiring harness

Related codes

Showing 21–30 of 40
F.65

Your boiler has detected that its internal control brain is overheating and has shut itself down to prevent damage.

High Engineer only £150-350

Parts commonly replaced

  • Main PCB
  • Wiring harness

Related codes

F.67

Your boiler's computer is struggling to safely detect or manage the flame, so it has shut itself down to prevent any unsafe operation.

High Engineer only £200-450

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Flame rectification electrode

Related codes

F.68

Your boiler is struggling to keep a steady flame, causing it to shut down for safety reasons.

High Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • PCB board
  • Flame sensor

Related codes

F.70

Your boiler has lost its unique digital identity, meaning the internal computer no longer knows how to correctly control your specific heating system.

High Engineer only £120-250

Parts commonly replaced

  • User Interface PCB
  • Main PCB

Related codes

F.71

Your boiler is struggling to accurately measure the temperature of the water flowing through the system, so it has safely shut itself down to prevent overheating.

High Engineer only £150-250

Parts commonly replaced

  • Flow NTC sensor
  • Return NTC sensor
  • Wiring harness

Related codes

F.72

Your boiler has detected that the sensors measuring water temperature going in and out are giving conflicting readings, so it has shut down as a safety precaution.

High Engineer only £120-220

Parts commonly replaced

  • Flow NTC sensor
  • Return NTC sensor
  • Sensor wiring harness

Related codes

F.73

Your boiler has lost the signal from its water pressure sensor, meaning it cannot accurately read the internal water level.

Medium Engineer only £120-220

Parts commonly replaced

  • Water pressure sensor
  • Wiring harness

Related codes

F.74

Your boiler has detected an electrical fault with its water pressure sensor, which usually prevents it from safely measuring the system pressure.

High Engineer only £120-250

Parts commonly replaced

  • Water pressure sensor
  • Wiring harness

Related codes

F.75

Your boiler is struggling to accurately read its internal water pressure, so it has locked out to keep itself safe.

High Engineer only £120-£250

Parts commonly replaced

  • Water pressure sensor
  • Pressure sensor wiring harness

Related codes

F.76

Your boiler has detected a critical safety disagreement between its internal components and has safely shut itself down to prevent any risk.

Emergency Engineer only £150-350

Parts commonly replaced

  • Primary heat exchanger safety cut-out
  • Gas valve assembly
  • Main PCB

Related codes

Showing 31–40 of 40
F.77

Your boiler has detected a potential blockage or mechanical issue with the system that manages exhaust gases, which has triggered a safety shutdown to prevent harmful gases from entering your home.

Emergency Engineer only £150-300

Parts commonly replaced

  • Flue non-return flap
  • Condensate trap assembly
  • PCB
F.78

Your boiler is having trouble communicating with an external hot water control component, meaning it doesn't know the temperature of the water heading to your taps.

High Engineer only £90-180

Parts commonly replaced

  • DHW NTC Sensor
  • External Link Box
  • Wiring harness

Related codes

F.83

Your boiler is not detecting enough water circulating inside the system to safely turn on the burner.

High Engineer only £120-250

Parts commonly replaced

  • Flow temperature sensor
  • Return temperature sensor
  • System pump
F.84

Your boiler has detected a mix-up with its internal temperature sensors, usually meaning they are reading the wrong pipes or have been incorrectly installed.

High Engineer only £90-180

Parts commonly replaced

  • Flow temperature sensor
  • Return temperature sensor
  • Sensor wiring harness

Related codes

F.85

Your boiler has stopped working because its internal thermometers are giving conflicting readings and believe they have been fitted to the wrong pipes.

High Engineer only £90-180

Parts commonly replaced

  • Flow temperature sensor
  • Return temperature sensor
  • NTC cable harness

Related codes

F.86

Your boiler has stopped providing heat because a safety limit switch for your underfloor heating has been triggered or disconnected.

High Engineer only £90-180

Parts commonly replaced

  • Underfloor heating limit thermostat
  • Wiring harness
  • External pump

Related codes

F.87

Your boiler is failing to light the flame properly because there is a communication issue with the part responsible for ignition.

High Engineer only £150-300

Parts commonly replaced

  • Ignition lead
  • Ignition electrode
  • Printed Circuit Board (PCB)

Related codes

F.88

Your boiler has detected an electrical connection issue with the gas valve, meaning it cannot safely ignite to provide heating or hot water.

High Engineer only £180-350

Parts commonly replaced

  • Gas valve
  • Wiring harness
  • Printed Circuit Board (PCB)

Related codes

F.89

Your boiler has detected an issue with the water pump's wiring or connection, meaning it cannot circulate water properly to provide heating or hot water.

High Engineer only £150-300

Parts commonly replaced

  • Water pump
  • Pump wiring harness

Related codes

F.97

Your boiler has detected an internal computer system failure and has safely shut down.

High Engineer only £300-500

Parts commonly replaced

  • Main PCB

Related codes

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.