No communication with the PCB Communication fault between display and PCB in the electronics box
Vaillant ecoTEC plus 612 Fault codes & diagnostics
50 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.
The fault code is already on your display
Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →
Severity at a glance
Each cell = one fault code. Hover to identify.Which version do you have?
The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.
| GC number | Appliance (register name) | Produced |
|---|---|---|
| 41-044-60 | ecoTEC plus 612 VU GB 126/5-5 | 2012–2015 |
Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.
All 50 documented codes
Tap any card for details
Fault list
Return temperature sensor interruption
Interruption cylinder charging sensor actoSTOR (NTC) only in combination with F.91
Interruption cylinder sensor actoSTOR (NTC) only in combination with F.91
Flow NTC short circuit
Return NTC short circuit
Short circuit at cylinder charging sensor (NTC) only in combination with F.91
VU-/VUW boiler: Short circuit warm start sensor/cylinder sensor; VUW boiler with actoSTOR: Short circuit cylinder sensor (NTC) only in combination with F.91
Safety switch-off: temperature limiter
Low water pressure; the boiler switches off
Safety switch-off: Temperature difference too great
Safety switch-off: Temperature rise too fast
Safety switch-off: Flue gas temperature too high
Fault: Gas valve without function
Safety switch-off: Flame simulation
Failure during start-up: ignition unsuccessful
F.29 Your boiler was working but has suddenly turned off because the flame has gone out and it cannot manage to relight itself.
Your boiler was working but has suddenly turned off because the flame has gone out and it cannot manage to relight itself.
What to check first
- Check if other gas appliances, like a hob, are still working to ensure your gas supply hasn't been interrupted.
- If it is freezing outside, check the condensate pipe (the plastic pipe leading outside) for ice and defrost it with warm water.
- Press the reset button (a flame symbol with a cross through it) for five seconds to see if the boiler restarts.
Parts commonly replaced
- Ignition Electrode
- Gas Valve
- Flame Sensing Electrode
- PCB
Related codes
Fan fault
Air/flue gas duct fault
Coding resistor fault (possible in combination with F.70)
eBUS fault
Mass flow sensor connection fault
F.53 Your boiler has detected an issue with the gas flow, meaning it cannot safely ignite or maintain a flame to heat your home.
Your boiler has detected an issue with the gas flow, meaning it cannot safely ignite or maintain a flame to heat your home.
Parts commonly replaced
- Gas valve
- Gas valve wiring harness
- Main PCB
Related codes
Gas pressure fault (in combination with F.28/F.29)
Fault: Mass flow sensor regulation
Fault during comfort safety mode
Fault: Gas valve regulation - Short circuit/short to earth in cable harness for the gas valve - Gas valve defective (coils shorted to earth) - Electronics defective
Fault: Gas valve switch-off delay - Delayed shutdown of gas valve - Delayed extinguishing of flame signal - Gas valve leaking - Electronics defective
EEPROM error Electronics defective
Electronics/NTC fault Supply or return NTC short circuited, electronics defective
Electronic temperature fault Electronics overheating due to external influences, electronics defective
Electronics/flame fault Implausible flame signal, electronics defective
Unstable flame signal fault Air in gas, gas flow pressure too low, wrong air ratio, condensate route blocked, wrong gas restrictor, ionisation flow interruption (cables, electrodes), flue gas recirculation, condensate route
Coding resistor fault (possible in combination with F.42)
Flow NTC fault Flow temperature sensor signalling constant value: - Flow temperature sensor incorrectly positioned at supply pipe. - Flow temperature sensor defective.
Flow/return NTC fault Flow/return NTC temperature difference too great -> flow and/or return temperature sensor defective
Water pressure sensor signal in the wrong range (too low) Interruption/short circuit of water pressure sensor, interruption/short circuit to GND in supply line to water pressure sensor or water pressure sensor defective
Water pressure sensor signal outside correct range (too high) Cable to water pressure sensor has short-circuited at 5 V/24 V or internal fault in water pressure sensor
Interruption Flow Fehler Pumpe/Wassermangel
Overheating protection on primary heat exchanger has responded Cable or cable connections for safety fuse in primary heat exchanger or primary heat exchanger defective
Flue non-return flap/condensate pump fault No response from flue non-return flap or condensate pump defective
Interruption to DHW outlet sensor at external controller UK link box is connected, but hot water NTC not bridged
Flow and/or return temperature sensor temperature change fault When the burner starts, the temperature change registered at flow and/or return temperature sensor is non-existent or too small. - Not enough water in the boiler - Flow and/return temperature sensor not in correct position at pipe.
Fault: Flow/return temperature sensor temperature difference implausible Flow and return temperature sensors returning implausible values. - Flow and return temperature sensors have been inverted. - Flow and return temperature sensors have not been correctly fitted.
Fault: Flow and return temperature sensors incorrectly fitted Flow and/or return temperature sensors have been fitted to the same pipe/wrong pipe.
F.91 Your boiler is having trouble communicating with the separate hot water storage tank, which may result in a loss of hot water.
Your boiler is having trouble communicating with the separate hot water storage tank, which may result in a loss of hot water.
Parts commonly replaced
- actoSTOR sensor
- Wiring harness
- PCB
Related codes
F.92 Your boiler has detected an issue with the type of gas it is receiving, meaning it has shut itself down to prevent unsafe operation.
Your boiler has detected an issue with the type of gas it is receiving, meaning it has shut itself down to prevent unsafe operation.
Parts commonly replaced
- Gas valve
- Printed Circuit Board (PCB)
- Gas supply pressure regulator
Related codes
F.93 Your boiler has detected an issue with the gas valve or the way it is communicating, meaning it cannot safely start up to provide heat or hot water.
Your boiler has detected an issue with the gas valve or the way it is communicating, meaning it cannot safely start up to provide heat or hot water.
Parts commonly replaced
- Gas valve
- Printed Circuit Board (PCB)
- Wiring harness
Related codes
DHW mode Burner on
Status & diagnostic codes 71 operating states & engineer diagnostics
Not faults — these are normal operating states. Tap to expand.
71 operating states & engineer diagnostics