The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
6 Emergency 34 High 8 Medium 2 Low

Which version do you have?

The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.

GC number Appliance (register name) Produced
41-044-64 ecoTEC plus 630 VU GB 306/5-5 2012–2015

Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.

All 50 documented codes

Tap any card for details

Communication fault

Your boiler's main electronic control board has temporarily lost connection with the display screen, meaning the system cannot coordinate heating or hot water.

High Engineer only £150-350

Parts commonly replaced

  • User interface display PCB
  • Main PCB
  • Internal wiring harness

Related codes

F.01

Your boiler has lost the connection to the sensor that monitors the temperature of the water returning to the unit, causing it to stop working for safety reasons.

High Engineer only £120-220

Parts commonly replaced

  • Return temperature sensor
  • Wiring harness

Related codes

F.02

Your boiler has detected a communication issue with the built-in hot water storage cylinder temperature sensor.

Medium Engineer only £100-200

Parts commonly replaced

  • Cylinder NTC sensor
  • Wiring harness

Related codes

F.03

Your boiler has lost communication with the built-in hot water storage tank sensor, which means it may struggle to provide consistent hot water.

Medium Engineer only £120-250

Parts commonly replaced

  • actoSTOR cylinder NTC sensor
  • Wiring harness

Related codes

F.10

Your boiler has stopped working because one of its internal sensors has developed an electrical fault and can no longer measure the temperature of the water leaving the unit.

High Engineer only £90-180

Parts commonly replaced

  • Flow NTC Thermistor
  • Wiring harness

Related codes

F.11

Your boiler has detected an electrical fault with the sensor that monitors water returning from your radiators, causing the system to shut down for safety.

High Engineer only £100-£180

Parts commonly replaced

  • Return NTC thermistor (sensor)
  • Wiring harness
  • Main PCB

Related codes

F.12

Your boiler has detected an electrical wiring or sensor fault related to how it heats your hot water cylinder.

Medium Engineer only £100-200

Parts commonly replaced

  • Cylinder temperature sensor (NTC)
  • Wiring harness

Related codes

F.13

Your boiler has detected a faulty electrical reading from a temperature sensor responsible for monitoring your hot water.

Medium Engineer only £90-£180

Parts commonly replaced

  • Hot water NTC sensor
  • Wiring harness

Related codes

F.20

Your boiler has detected that it is getting too hot and has automatically shut down to prevent damage or overheating.

High Engineer only £120-250

Parts commonly replaced

  • NTC Thermistor
  • Pump
  • Heat Exchanger
  • PCB

Related codes

Showing 11–20 of 50
F.22

Your boiler has automatically switched off because the water pressure inside the system has dropped too low to run safely.

High DIY-safe

What to check first

  1. Locate the filling loop (two valves connected by a silver braided hose under the boiler).
  2. Open both valves slowly to let mains water into the system until the pressure gauge on the front reads between 1.0 and 1.5 bar.
  3. Close both valves tightly and check the pressure holds steady.

Parts commonly replaced

  • Pressure sensor
  • Expansion vessel
  • Auto air vent

Related codes

F.23

Your boiler has detected that the water inside it is heating up or moving much faster than expected, so it has shut itself down to prevent any damage.

High Engineer only £150-300

Parts commonly replaced

  • Pump
  • NTC sensors
  • Heat exchanger

Related codes

F.24

Your boiler has detected that the water inside it is heating up much faster than it safely should, causing it to shut down to prevent damage.

High Engineer only £150-350

Parts commonly replaced

  • Central heating pump
  • System filter
  • Heat exchanger
  • Flow sensor

Related codes

F.25

Your boiler has detected that the gases it is producing are too hot to be safe, so it has automatically shut down to prevent damage.

Emergency Engineer only £150-350

Parts commonly replaced

  • Flue gas temperature sensor
  • NTC thermistor
  • Primary heat exchanger

Related codes

F.26

Your boiler is unable to open the internal valve that supplies gas to the burner, meaning it cannot ignite to provide heat or hot water.

High Engineer only £180-350

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

F.27

Your boiler has detected a signal that suggests a flame is present even when the burner is turned off, causing it to shut down for your safety.

High Engineer only £150-300

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Flame detection probe

Related codes

F.28

Your boiler is trying to start but cannot get the flame to light or stay lit.

High Engineer only £150-350

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB

Related codes

F.29

Your boiler was working but has suddenly turned off because the flame has gone out and it cannot manage to relight itself.

High DIY-safe £100-£350

What to check first

  1. Check if other gas appliances, like a hob, are still working to ensure your gas supply hasn't been interrupted.
  2. If it is freezing outside, check the condensate pipe (the plastic pipe leading outside) for ice and defrost it with warm water.
  3. Press the reset button (a flame symbol with a cross through it) for five seconds to see if the boiler restarts.

Parts commonly replaced

  • Ignition Electrode
  • Gas Valve
  • Flame Sensing Electrode
  • PCB

Related codes

F.32

Your boiler has detected that the internal fan responsible for safely venting exhaust gases is not spinning, so it has shut down to prevent unsafe operation.

High Engineer only £200-350

Parts commonly replaced

  • Fan unit
  • Printed Circuit Board (PCB)
  • Wiring harness
F.35

Your boiler has detected a blockage or issue with the pipe that brings in fresh air and removes exhaust gases.

Emergency Engineer only £90-200

Parts commonly replaced

  • Flue terminal
  • Air pressure switch
  • Fan assembly
  • Flue seals

Related codes

Showing 21–30 of 50
F.42

Your boiler has lost its memory of which specific model it is, meaning it cannot operate safely without professional reconfiguration.

High Engineer only £90-180

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • Coding resistor plug

Related codes

F.49

Your boiler has lost its internal communication signal, meaning the main control board and internal components can no longer properly talk to each other.

High Engineer only £150-350

Parts commonly replaced

  • Main PCB
  • eBUS wiring harness

Related codes

F.52

Your boiler has lost communication with a sensor that monitors the flow of air and gas, so it has safely shut down to prevent incorrect operation.

High Engineer only £120-250

Parts commonly replaced

  • Air pressure sensor
  • Wiring harness
  • Main printed circuit board (PCB)

Related codes

F.53

Your boiler has detected an issue with the gas flow, meaning it cannot safely ignite or maintain a flame to heat your home.

Emergency Engineer only £180-350

Parts commonly replaced

  • Gas valve
  • Gas valve wiring harness
  • Main PCB

Related codes

F.54

Your boiler has temporarily stopped working because it is not detecting enough gas supply to safely light the flame.

High Engineer only £120-£250

Parts commonly replaced

  • Gas valve
  • Gas regulator
  • Gas meter

Related codes

F.56

Your boiler has detected an issue with how it regulates the flow of gas and air inside, so it has temporarily locked itself out for safety.

High Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • Air pressure sensor
  • Main printed circuit board

Related codes

F.57

Your boiler has detected an issue while trying to operate safely in its high-performance mode, so it has temporarily locked itself out to prevent any potential risks.

High Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • Main PCB
  • NTC thermistor

Related codes

F.61

Your boiler has detected an electrical fault with the valve that controls the gas supply, meaning it has safely locked itself out to prevent unsafe operation.

Emergency Engineer only £150-350

Parts commonly replaced

  • Gas valve
  • Wiring harness
  • Main printed circuit board (PCB)

Related codes

F.62

Your boiler has detected an issue where the gas supply is not shutting off as quickly as it should, which requires a professional gas engineer to inspect for safety.

Emergency Engineer only £150-350

Parts commonly replaced

  • Gas valve
  • Main printed circuit board (PCB)

Related codes

F.63

Your boiler's internal computer brain has developed a memory error and can no longer process the information it needs to run safely.

High Engineer only £250-£450

Parts commonly replaced

  • Main Printed Circuit Board (PCB)

Related codes

Showing 31–40 of 50
F.64

Your boiler has detected a temperature sensor or electronic control error, so it has safely shut down to prevent damage.

High Engineer only £150-300

Parts commonly replaced

  • NTC temperature sensor
  • Main printed circuit board (PCB)

Related codes

F.65

Your boiler has detected that its main electronic control board is overheating or experiencing a serious temperature fault.

High Engineer only £200-450

Parts commonly replaced

  • Main printed circuit board (PCB)
  • Temperature sensor

Related codes

F.67

Your boiler has detected an internal electronic problem with how it reads the flame signal, meaning it has safely shut down to prevent unsafe operation.

High Engineer only £250-£450

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • Wiring harness

Related codes

F.68

Your boiler has temporarily shut down because the flame burning inside it is flickering or becoming unstable.

High Engineer only £100-£250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Condensate trap

Related codes

F.70

Your boiler's electronic control board has lost its identity settings and can no longer recognize which specific model it is installed in.

High Engineer only £150-300

Parts commonly replaced

  • Coding resistor
  • Printed Circuit Board (PCB)

Related codes

F.71

Your boiler has temporarily stopped working because it is receiving an incorrect temperature reading from one of its internal sensors.

High Engineer only £90-180

Parts commonly replaced

  • Flow temperature sensor
  • Sensor wiring harness

Related codes

F.72

Your boiler has detected an inconsistent temperature reading between its internal sensors, which stops it from running safely.

High Engineer only £120-£220

Parts commonly replaced

  • Flow temperature sensor
  • Return temperature sensor
  • Sensor wiring harness

Related codes

F.73

Your boiler is not receiving a proper signal from its water pressure sensor, meaning it cannot accurately check the water level inside the system.

High Engineer only £90-180

Parts commonly replaced

  • Water pressure sensor
  • Wiring harness

Related codes

F.74

Your boiler has detected an electrical reading from the water pressure sensor that is too high, meaning it cannot safely monitor the system pressure.

Medium Engineer only £120-250

Parts commonly replaced

  • Water pressure sensor
  • Wiring harness

Related codes

F.75

Your boiler has detected a pressure drop or a problem with the water pump starting up, so it has shut down to protect itself.

High DIY-safe £150-350

What to check first

  1. Check your boiler's pressure gauge to see if it has dropped below 1.0 bar.
  2. If the pressure is low, use the filling loop to top the system back up to between 1.0 and 1.5 bar.
  3. Reset the boiler using the reset button to see if the pump clears and normal operation resumes.

Parts commonly replaced

  • Water Pressure Sensor
  • Central Heating Pump

Related codes

Showing 41–50 of 50
F.76

Your boiler has automatically shut down because a safety device detected that the main part of the boiler has become dangerously hot.

High Engineer only £150-350

Parts commonly replaced

  • Primary heat exchanger safety fuse
  • Wiring harness
  • Primary heat exchanger

Related codes

F.77

Your boiler has detected an issue with the system that removes waste water or controls the exhaust gases, causing it to lock out for safety.

High Engineer only £150-300

Parts commonly replaced

  • Condensate pump
  • Flue non-return flap
  • Printed Circuit Board (PCB)

Related codes

F.78

Your boiler is having trouble communicating with the external controls or hot water system, which is preventing it from heating your water correctly.

High Engineer only £120-250

Parts commonly replaced

  • VR65 or VR66 Wiring Centre
  • Hot Water Cylinder NTC Sensor
  • Wiring loom
F.83

Your boiler has detected that the water inside is not heating up or moving properly when the burner tries to start.

High DIY-safe £100-£250

What to check first

  1. Check your boiler's pressure gauge to ensure it is between 1 and 1.5 bars.
  2. If the pressure is too low, use the filling loop to top up the system.
  3. Reset the boiler once the correct pressure is restored.

Parts commonly replaced

  • NTC Temperature Sensor
  • Pressure Sensor

Related codes

F.84

Your boiler has detected an unusual temperature difference between its internal pipes, usually because the monitoring sensors are misread, incorrectly attached, or recently swapped during maintenance.

Medium Engineer only £90-180

Parts commonly replaced

  • Flow/return temperature sensor
  • NTC thermistor

Related codes

F.85

Your boiler's temperature sensors have been attached to the wrong pipes by mistake, so the system cannot properly measure how water is flowing through it.

Medium Engineer only £90-180

Parts commonly replaced

  • Flow temperature sensor
  • Return temperature sensor
  • Sensor wiring harness

Related codes

F.91

Your boiler is having trouble communicating with the separate hot water storage tank, which may result in a loss of hot water.

Medium Engineer only £120-250

Parts commonly replaced

  • actoSTOR sensor
  • Wiring harness
  • PCB

Related codes

F.92

Your boiler has detected an issue with the type of gas it is receiving, meaning it has shut itself down to prevent unsafe operation.

Emergency Engineer only £150-350

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board (PCB)
  • Gas supply pressure regulator

Related codes

F.93

Your boiler has detected an issue with the gas valve or the way it is communicating, meaning it cannot safely start up to provide heat or hot water.

High Engineer only £180-350

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

71 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.

D.000 Diagnostic This code is simply a status message showing the boiler is currently operating at a reduced capacity, not a fault requiring any action. D.001 Diagnostic Your boiler is currently cooling down by circulating water through the system after the heating has switched off, which is a normal part of the shutdown process. D.002 Diagnostic Your boiler is currently in a waiting period between heating cycles to prevent it from switching on and off too frequently, which is a normal protective feature. D.003 Diagnostic Your boiler is simply reporting the current temperature of the water flowing out of it, which is a normal status reading rather than an active fault. D.004 Diagnostic Your boiler is struggling to accurately read or detect the current temperature of your hot water cylinder. D.005 Diagnostic Your boiler is simply reporting the current temperature target for the water circulating through your radiators, rather than indicating a fault. D.006 Diagnostic This code indicates that the boiler is simply reporting the temperature it is currently aiming to reach for your heating or hot water, rather than flagging an actual fault. D.007 Diagnostic This code indicates your boiler is simply reporting the current temperature setting for your hot water comfort mode, rather than showing a fault. D.008 Diagnostic Your boiler has lost the connection to its external heating controls, such as your thermostat or timer, preventing it from knowing when to turn on the heating. D.009 Diagnostic Your boiler is struggling to communicate correctly with its external controls, such as your room thermostat or smart controller. D.010 Diagnostic Your boiler is having trouble circulating water because the internal pump responsible for moving heat around your home has detected a wiring or electrical issue. D.011 Diagnostic Your boiler is having trouble communicating with the water pump that helps circulate heat around your home, which means it has stopped heating to prevent damage. D.012 Diagnostic Your boiler is struggling to pump hot water into your hot water cylinder, which means you may have no hot water available. D.013 Diagnostic Your boiler is struggling to push water around your radiators because it cannot detect that the internal water pump is working properly. D.014 Diagnostic Your boiler is struggling to communicate with the internal pump that moves hot water around your radiators and taps, causing it to stop operating correctly. D.015 Diagnostic Your boiler is struggling to confirm that the internal water pump is spinning at the correct speed to circulate heat through your radiators. D.016 Diagnostic Your boiler is currently operating normally and is confirming it has received a signal to turn on the heating. D.017 Diagnostic Your boiler's communication settings are currently mismatched or incorrectly configured, preventing it from talking to your heating controls properly. D.018 Diagnostic Your boiler is simply indicating that the internal water pump is currently running to move heat around your system. D.019 Diagnostic This code is simply an information display showing that your boiler's internal pump is currently set to run in a two-stage mode. D.020 Diagnostic Your boiler is currently monitoring or waiting for the hot water temperature to reach its target level, and this is typically a normal operating status rather than a breakdown. D.022 Diagnostic Your boiler is simply indicating that it has detected a request for hot water to be produced. D.023 Diagnostic Your boiler is currently just confirming that it is in heating mode and is waiting for the pump to reach the required speed before igniting. D.025 Diagnostic Your boiler is currently busy heating your hot water cylinder, which is a normal part of its routine operation. D.026 Diagnostic Your boiler has detected an issue with the internal electrical component that controls external accessories, such as an external pump or zone valve. D.027 Diagnostic Your boiler is struggling to communicate with an external add-on component, such as an external pump or a specialized heating zone controller. D.028 Diagnostic Your boiler is having trouble communicating with an add-on device, such as an external pump or a specialized heating zone control. D.033 Diagnostic Your boiler is struggling to detect or control the speed of the internal fan that pushes out waste gases. D.034 Diagnostic Your boiler is struggling to confirm that the internal fan, which clears exhaust gases safely, is spinning at the correct speed to operate. D.035 Diagnostic Your boiler is struggling to switch between heating your radiators and heating your hot water because an internal diverter valve is stuck or failing. D.036 Diagnostic Your boiler is struggling to detect or maintain the flow of hot water, which may cause your hot taps to run cold or the water temperature to fluctuate. D.039 Diagnostic Your boiler is receiving an unusual temperature reading from the solar thermal panel system connected to your hot water supply. D.040 Diagnostic Your boiler is simply reporting the current temperature of the water flowing through your system, which is a normal status update rather than a fault. D.041 Diagnostic Your boiler is struggling to accurately measure the temperature of the water returning to it from your radiators. D.044 Diagnostic Your boiler is struggling to detect the flame correctly, which prevents it from firing up reliably to heat your home. D.046 Diagnostic Your boiler is currently running a self-check on its internal water pump to ensure it is moving water around your heating system correctly. D.047 Diagnostic Your boiler is simply displaying the current temperature reading from an external weather sensor and is not indicating a fault. D.050 Diagnostic Your boiler is having trouble managing the speed of its internal fan, which is preventing it from running properly. D.051 Diagnostic Your boiler has detected an incorrect fan speed setting, which is preventing it from firing up correctly to provide heating or hot water. D.058 Diagnostic Your boiler is currently waiting for a signal from your solar hot water system to decide whether it needs to add extra heat to your water supply. D.060 Diagnostic Your boiler has detected that it has shut itself down due to overheating several times, suggesting an underlying issue with internal water circulation or heat dissipation. D.061 Diagnostic Your boiler has detected multiple failed attempts to light the burner and has temporarily stopped trying to prevent a potential gas buildup. D.064 Diagnostic Your boiler is struggling to ignite smoothly, which means it is taking longer than expected to establish a stable flame when it tries to start up. D.065 Diagnostic Your boiler has failed to light the flame within the allowed time frame, so it has safely shut itself down to prevent gas buildup. D.067 Diagnostic Your boiler is currently in a temporary rest period to prevent it from cycling on and off too frequently, and it will resume heating automatically shortly. D.068 Diagnostic Your boiler is struggling to ignite on the first try and is recording the number of times it has attempted to start up. D.069 Diagnostic Your boiler is struggling to ignite on the first try and is having to make a second attempt to get the flame going. D.070 Diagnostic Your boiler is struggling to switch between heating your radiators and heating your hot water because an internal diverter component is failing to move correctly. D.071 Diagnostic Your boiler has reached its maximum allowed heating temperature limit and is temporarily pausing to prevent overheating. D.072 Diagnostic Your boiler is briefly running its water pump to move excess heat away from the tank after it has finished heating your hot water, which is a normal part of the cooling process. D.073 Diagnostic Your boiler is currently recalibrating its internal temperature settings to ensure the water stays at the correct level of warmth, which is typically just a brief background process. D.075 Diagnostic Your boiler has taken too long to heat your hot water cylinder, causing it to pause the process to prevent the system from overheating. D.076 Diagnostic Your boiler has lost its unique digital identification code, meaning it no longer recognises its own configuration settings. D.077 Diagnostic Your boiler is currently running in a temporary mode that limits its power while heating your hot water, likely because it is adjusting to system demand. D.078 Diagnostic Your boiler is temporarily limiting the temperature of your hot water to protect itself from overheating while it performs an internal system check. D.080 Diagnostic This code is simply an information display showing the total number of hours your boiler has spent heating your radiators and is not a sign of a fault. D.081 Diagnostic This code is simply an information display showing the total number of hours your boiler has spent heating your domestic hot water, rather than indicating a fault. D.082 Diagnostic Your boiler is simply letting you know that it is currently in the process of starting up its burner to heat your home. D.083 Diagnostic Your boiler is simply performing a routine task to start heating up your hot water. D.084 Diagnostic Your boiler has reached its scheduled interval for a routine service check to ensure it remains efficient and safe. D.088 Diagnostic Your boiler is struggling to detect the flow of water needed to provide hot water to your taps, usually due to a blockage or a faulty sensor. D.090 Diagnostic Your boiler is having trouble communicating with the digital control panel or thermostat connected to it. D.091 Diagnostic Your boiler is struggling to pick up the radio signal that automatically sets its internal clock. D.093 Diagnostic Your boiler has lost its unique configuration settings, usually because the main control board has been replaced or reset and hasn't been programmed correctly for your specific model. D.094 Diagnostic Your boiler's memory of past errors has been successfully wiped and cleared. D.095 Diagnostic Your boiler is simply displaying a technical identification number for its internal software and is not actually experiencing a fault. D.096 Diagnostic Your boiler has reverted to its original factory settings, which means any personalised heating or hot water timings and temperatures you previously saved have been wiped and will need to be reconfigured. D.098 Diagnostic Your boiler has lost its unique electronic identity key, preventing it from knowing exactly which settings it should use to operate correctly. S.11 Status Your boiler is trying to heat your water, but the internal fan responsible for safety cannot get started. S.16 Status Your boiler's fan is still spinning after the hot water has been turned off, preventing the system from restarting safely. S.17 Status Your boiler is busy cooling itself down after providing hot water, but the water isn't moving through the system as quickly as it should.