The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
4 Emergency 33 High 3 Medium 42 Low

Which version do you have?

The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.

GC number Appliance (register name) Produced
47-044-52 ecoTEC pro 30 H combi A VUW GB 306/5-3 2015–present

Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.

All 82 documented codes

Tap any card for details

F.00

Your boiler has lost connection with its internal thermometer, meaning it cannot safely tell how hot the water is and has shut down as a precaution.

High Engineer only £90-160

Parts commonly replaced

  • NTC Flow Temperature Sensor
  • Sensor Wiring Harness

Related codes

F.01

Your boiler has stopped working because it cannot communicate with the sensor that monitors the temperature of the water returning from your radiators.

High Engineer only £90-160

Parts commonly replaced

  • Return temperature sensor (NTC thermistor)
  • Sensor wiring harness

Related codes

F.10

Your boiler has detected an electrical fault with the internal sensor that monitors the temperature of the water leaving the unit, causing it to shut down for safety.

High Engineer only £100-£180

Parts commonly replaced

  • Flow Temperature Sensor (NTC)
  • Wiring Harness

Related codes

F.11

Your boiler has stopped working because a internal sensor that monitors the temperature of the water returning to the unit has developed an electrical fault.

High Engineer only £90-160

Parts commonly replaced

  • Return temperature sensor (NTC)
  • Wiring harness

Related codes

F.20

Your boiler has shut itself down because it has detected that it is getting far too hot, usually due to a lack of water flow or a circulation blockage.

High DIY-safe £100-£350

What to check first

  1. Check that your boiler pressure is between 1.0 and 1.5 bar on the digital display or gauge.
  2. Ensure all radiator valves are fully open to allow water to circulate.
  3. Try resetting the boiler by pressing the button with the flame symbol 'X' crossed out.

Parts commonly replaced

  • Overheat Thermostat (Limit NTC)
  • Circulation Pump
  • Main Heat Exchanger (Cleaning/Flushing)

Related codes

F.22

Your boiler has temporarily stopped working because the water pressure inside the system has dropped too low.

High DIY-safe

What to check first

  1. Locate the filling loop underneath your boiler or near the hot water cylinder.
  2. Open the valves slowly to let water into the system until the pressure gauge on the front panel reads between 1.0 and 1.5 bar.
  3. Close both valves firmly and check the display to see if the code clears.

Parts commonly replaced

  • Pressure sensor
  • Expansion vessel
  • Isolation valve

Related codes

F.23

Your boiler has shut down because water isn't moving through the system quickly enough, causing it to overheat too rapidly.

High DIY-safe £150-£350

What to check first

  1. Check that all radiator valves (TRVs) are turned to the highest setting
  2. Ensure the boiler pressure is between 1.0 and 1.5 bar on the digital display
  3. Check for recent air locks and bleed your radiators if they have cold spots

Parts commonly replaced

  • Circulation Pump
  • Flow/Return Thermistor
  • Main Heat Exchanger (De-scale)

Related codes

F.24

Your boiler is shutting down because the water inside is heating up much faster than normal, which usually points to a blockage preventing proper water flow.

High DIY-safe £150-350

What to check first

  1. Check that your system pressure is at the correct level (around 1 to 1.5 bar).
  2. Ensure your heating radiators are turned on and their valves are fully open to allow water to circulate.
  3. Try resetting the boiler using the reset button on the control panel.

Parts commonly replaced

  • Pump
  • Heat exchanger
  • Bypass valve

Related codes

F.25

Your boiler has automatically shut down because the exhaust gases leaving the system are dangerously hot.

Emergency Engineer only £150-350

Parts commonly replaced

  • Flue gas safety sensor
  • Main heat exchanger
  • Printed circuit board (PCB)

Related codes

F.26

Your boiler has detected an issue with the gas valve that controls the fuel supply, meaning it cannot safely ignite.

Emergency Engineer only £180-350

Parts commonly replaced

  • Gas valve
  • Main PCB
  • Wiring harness

Related codes

Showing 11–20 of 82
F.27

Your boiler has detected a signal that suggests a flame is present even when the burner is turned off, causing it to shut down for your safety.

High Engineer only £150-300

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Flame detection probe

Related codes

F.28

Your boiler is trying to start up and ignite the gas, but the flame is failing to light.

High DIY-safe £100-250

What to check first

  1. Check if your gas supply is working properly by testing another gas appliance like a hob.
  2. Check if your pre-payment gas meter has run out of credit if you use one.
  3. Press the reset button (a flame symbol with a cross through it) on your boiler to try clearing the error.

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

F.29

Your boiler tried to light its flame several times but couldn't stay lit, so it has locked itself out for safety.

High Engineer only £150-350

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Circuit board (PCB)

Related codes

F.32

Your boiler has stopped working because it cannot detect that the internal fan, which safely pushes harmful gases outside, is spinning correctly.

High Engineer only £150-350

Parts commonly replaced

  • Fan assembly
  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

F.49

Your boiler is having trouble communicating with its external controllers or thermostats, preventing it from receiving instructions to heat your home.

High Engineer only £120-250

Parts commonly replaced

  • eBUS interface card
  • PCB
  • Wiring harness

Related codes

F.61

Your boiler has detected an issue with the internal gas valve control, meaning it cannot safely release gas to light the burner.

High Engineer only £200-350

Parts commonly replaced

  • Gas valve
  • Main printed circuit board (PCB)

Related codes

F.62

Your boiler has detected an issue with the gas valve shutting down properly, meaning it is safely locking itself out to prevent any potential safety hazards.

Emergency Engineer only £150-350

Parts commonly replaced

  • Gas valve
  • Main printed circuit board (PCB)

Related codes

F.63

Your boiler's internal computer has encountered a memory error and cannot read the essential configuration data required to operate safely.

High Engineer only £300-600

Parts commonly replaced

  • Main PCB
  • Display PCB

Related codes

F.64

Your boiler has detected an internal electronic or sensor glitch and has safely shut down to prevent damage.

High Engineer only £150-350

Parts commonly replaced

  • Main printed circuit board (PCB)
  • Temperature sensors

Related codes

F.65

Your boiler has detected that the temperature of its internal electronic components is too high, so it has safely shut down to prevent permanent damage.

High Engineer only £150-350

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Main Electronic Control Unit

Related codes

Showing 21–30 of 82
F.67

Your boiler has detected an internal communication problem with its electronic control system, meaning it cannot safely confirm the flame is burning correctly.

High Engineer only £250-500

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Flame rectification sensor

Related codes

F.68

Your boiler is temporarily locking out because the flame inside is flickering or going out unexpectedly, meaning you currently have no heating or hot water.

High Engineer only £120-300

Parts commonly replaced

  • Flame sensor / Electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

F.70

Your boiler's computer memory has become corrupted, usually after a part has been replaced without being programmed correctly.

High Engineer only £90-180

Parts commonly replaced

  • Main Printed Circuit Board (PCB)

Related codes

F.71

Your boiler is temporarily unable to accurately measure the temperature of the water flowing through the system, so it has safely shut down to prevent overheating.

High Engineer only £120-220

Parts commonly replaced

  • Flow NTC sensor
  • Wiring harness

Related codes

F.72

Your boiler has detected a temperature mismatch between its internal water pipes, meaning it cannot safely regulate its heating.

High Engineer only £120-250

Parts commonly replaced

  • Flow temperature sensor
  • Return temperature sensor
  • Wiring harness

Related codes

F.73

Your boiler is temporarily locked out because the internal sensor is not properly reading the water pressure in the system.

High Engineer only £90-180

Parts commonly replaced

  • Water pressure sensor
  • Wiring harness

Related codes

F.74

Your boiler has detected an electrical fault with the internal water pressure sensor, which is sending an abnormally high signal.

Medium Engineer only £120-250

Parts commonly replaced

  • Water pressure sensor
  • Wiring harness

Related codes

F.75

Your boiler has detected a pressure drop or a problem with the water pump upon starting up, so it has safely shut down to prevent damage.

High DIY-safe £150-350

What to check first

  1. Check your boiler pressure gauge on the front panel to see if it has dropped below 1 bar.
  2. If the pressure is low, use the filling loop underneath the boiler to top the system back up to between 1.0 and 1.5 bar.
  3. Reset the boiler using the flame-cross button to see if normal operation resumes.

Parts commonly replaced

  • Central heating pump
  • Pressure sensor

Related codes

F.77

Your boiler has detected an issue with the way waste water or gases are leaving the system, causing it to lock out for safety.

High Engineer only £150-300

Parts commonly replaced

  • Condensate pump
  • Non-return valve
  • Wiring harness

Related codes

F.78

Your boiler has detected a communication issue with a hot water sensor, which temporarily affects its ability to properly regulate the temperature of your hot water.

Medium Engineer only £90-180

Parts commonly replaced

  • Domestic Hot Water Sensor
  • Wiring Harness
  • Printed Circuit Board (PCB)

Related codes

Showing 31–40 of 82
F.83

Your boiler has detected an abnormal temperature difference between its sensors, meaning it cannot safely regulate the heat.

High Engineer only £120-250

Parts commonly replaced

  • NTC thermistor
  • Flow sensor
  • Main printed circuit board

Related codes

F.84

Your boiler has detected a confusing difference in temperature readings between its internal sensors, so it has safely shut down to prevent damage.

High Engineer only £120-250

Parts commonly replaced

  • NTC Temperature Sensor
  • Flow / Return Thermistors
  • Main Printed Circuit Board (PCB)

Related codes

F.85

Your boiler has detected that its temperature sensors have been installed on the wrong pipes during recent maintenance or installation.

High Engineer only £90-180

Parts commonly replaced

  • Flow/Return NTC Thermistors
  • Wiring Harness

Related codes

Showing 41–50 of 82
S.07

Your boiler is operating normally and simply running the internal water pump for a short moment after heating finishes to cool itself down.

Low Engineer only
S.11

Your boiler is simply preparing to provide hot water by starting up its internal fan, which is a normal part of its routine operation.

Low DIY-safe

What to check first

  1. Wait a moment to see if the boiler proceeds to ignite and supply hot water normally.
  2. Check if the display returns to normal once you turn off the hot water tap.

Related codes

S.16

Your boiler is simply running its fan for a short time after you turn off the hot water to safely clear out any remaining heat.

Low Engineer only
Showing 51–60 of 82
S.27

Your boiler is just safely cooling down after running the hot water tap, which is a normal part of its shutdown process.

Low Engineer only
S.28

Your boiler is temporarily delaying heating hot water to protect itself from turning on and off too frequently, which is a normal safety feature and usually resolves itself within a few minutes.

Low DIY-safe

What to check first

  1. Wait 5 to 10 minutes for the built-in delay timer to naturally expire.
  2. Check that your hot water taps are fully closed and not dripping.
  3. If the boiler remains stuck, try turning the hot water temperature down slightly on the control panel.

Related codes

S.30

Your boiler is temporarily pausing the heating because an external room thermostat or smart control is telling it not to switch on.

Low DIY-safe

What to check first

  1. Check your room thermostat or smart heating controller (like a Nest, Hive, or wall dial) to ensure the target temperature is set higher than the current room temperature.
  2. Replace the batteries in your wireless room thermostat, as flat batteries can block heating signals.
  3. Turn your heating controls off and on again to reset the connection between the thermostat and the boiler.

Parts commonly replaced

  • Room thermostat
  • Receiver unit
  • Wiring centre

Related codes

S.31

Your boiler is simply set to summer mode, which means the central heating is turned off while hot water continues to work normally.

Low DIY-safe

What to check first

  1. Check your boiler control panel or external room thermostat.
  2. Switch the operating mode from summer mode (often indicated by a sun icon or hot water only) to winter/heating mode.
  3. Increase the target room temperature above the current room temperature to trigger a heat demand.

Related codes

Showing 61–70 of 82
S.32

Your boiler is pausing briefly to check that the exhaust fan is ready before it safely switches on.

Low Engineer only

Parts commonly replaced

  • Flue gas fan
  • Printed Circuit Board

Related codes

S.34

Your boiler has automatically activated its built-in frost protection mode because the internal temperature has dropped too low.

Low DIY-safe

What to check first

  1. Wait for the boiler to complete its frost protection cycle once internal temperatures rise.
  2. Ensure your heating controls and thermostat are switched on so the boiler can maintain a safe background temperature.
  3. Check that your property is adequately heated and internal pipes are not at risk of freezing during severe cold weather.

Related codes

S.39

Your boiler has temporarily stopped because a safety device, such as a high-limit thermostat or condensate pump, has been triggered.

High Engineer only £90-200

Parts commonly replaced

  • Surface-mounted thermostat
  • Condensate pump
  • Condensate pipework

Related codes

S.40

Your boiler is currently pausing its operation as a temporary safety measure to protect itself, and it should resume normal heating once the internal temperatures balance out.

Low DIY-safe

What to check first

  1. Wait 15 to 30 minutes to see if the boiler automatically clears the message and resumes normal operation.
  2. Check that your heating controls and thermostats are not constantly demanding heat at maximum capacity.
  3. If the code persists, try restarting the boiler using its power switch or reset button.

Related codes

S.41

Your boiler has stopped working because the water pressure inside the system has risen higher than it should be.

High DIY-safe

What to check first

  1. Locate the filling loop valves connected to your boiler pipes.
  2. Ensure both filling valves are fully closed so no extra water is entering the system.
  3. Bleed one or two of your radiators slightly to let some water out and bring the pressure gauge back down to the green zone (around 1 to 1.5 bar).

Parts commonly replaced

  • Pressure relief valve
  • Expansion vessel
  • Filling loop valve

Related codes

S.42

Your boiler has temporarily stopped working because it has detected an issue with the safety flap in the exhaust pipe or the water drainage pump.

High Engineer only £150-300

Parts commonly replaced

  • Condensate pump
  • Flue non-return flap
  • Multi-functional module

Related codes

S.46

Your boiler has temporarily adjusted its settings to keep working smoothly because the flame flickered slightly at a very low power setting.

Low Engineer only
S.53

Your boiler has temporarily paused heating because it detected not enough water or a blockage stopping heat from flowing away properly.

Medium DIY-safe £90-250

What to check first

  1. Check your system pressure gauge to ensure it is sitting between 1 and 1.5 bar
  2. Use the filling loop to top up the water pressure if it has dropped below 1 bar
  3. Check your radiators to see if any are cold and need bleeding to release trapped air

Parts commonly replaced

  • Water pressure sensor
  • Circulating pump
  • Automatic air vent

Related codes

S.54

Your boiler has temporarily paused to protect itself because the water pressure inside the system has dropped too low.

High DIY-safe

What to check first

  1. Locate the filling loop (usually two valves connected by a silver braided hose underneath your boiler).
  2. Slowly open both valves until you hear water entering the system and the pressure gauge needle rises to between 1.0 and 1.5 bar.
  3. Firmly close both valves and check your boiler display to see if the code clears.

Parts commonly replaced

  • Pressure relief valve
  • Pressure sensor
  • Expansion vessel

Related codes

S.57

Your boiler is currently taking a temporary pause as part of its built-in testing programme and should resume normal operation on its own very soon.

Low Engineer only
Showing 71–80 of 82
S.58

Your boiler is temporarily running at a lower power than usual to protect itself or manage your home's current heating needs.

Low Engineer only
S.61

Your boiler has detected a configuration mismatch between its internal computer setting and the type of gas being supplied to your home.

High Engineer only £90-180

Parts commonly replaced

  • Coding Resistor
  • Main Printed Circuit Board (PCB)

Related codes

S.63

Your boiler has paused its operation because it detected a potential problem with the gas supply route to the unit.

Emergency Engineer only £100-250

Parts commonly replaced

  • Gas valve
  • Gas meter regulator
  • Electronic control board

Related codes

S.76

Your boiler is reminding you that a scheduled service is due soon, while also suggesting you check the water pressure.

Low DIY-safe £80-120

What to check first

  1. Check the pressure gauge on the front of your boiler to ensure it sits between 1.0 and 1.5 bar
  2. If the pressure is low, top it up using the filling loop
  3. Book an annual boiler service with a Gas Safe registered engineer to clear the reminder

Related codes

S.88

Your boiler is simply running its automatic air-purge routine to clear trapped air from the system, which usually happens right after it has been switched on or refilled.

Low DIY-safe

What to check first

  1. Wait for a few minutes to let the automatic purge cycle finish and the boiler to return to normal operation.
  2. Check your system pressure gauge to ensure it is sitting between 1 and 1.5 bar.
  3. If the code does not clear after a while, simply restart the boiler.

Related codes

S.92

Your boiler is currently running an automated safety check to test how well water is flowing through the system.

Low DIY-safe

What to check first

  1. Wait a few moments for the boiler to complete its automated test cycle.
  2. Check that your heating and hot water resume normal operation once the code clears.

Related codes

S.93

Your boiler is temporarily pausing operation to run a mandatory self-test on its exhaust gases, but this is usually an automated state that clears on its own.

Low DIY-safe

What to check first

  1. Wait a few minutes to see if the boiler clears the status message automatically
  2. Press the reset button if the boiler remains locked in this state
  3. Check that the flue terminal outside is completely clear of snow, leaves, or blockages

Related codes

S.96

Your boiler is currently running a quick diagnostic self-check on one of its internal temperature sensors.

Low Engineer only

Parts commonly replaced

  • Return temperature sensor

Related codes

S.97

Your boiler is currently running a brief internal check on its water pressure sensor to ensure it is reading correctly.

Low Engineer only

Parts commonly replaced

  • Water pressure sensor
  • Main printed circuit board (PCB)

Related codes

Showing 81–82 of 82
S.98

Your boiler is currently running a routine internal safety check to test its temperature sensors before allowing the system to operate.

Low Engineer only

Parts commonly replaced

  • Flow/return temperature sensor
  • Main printed circuit board

Related codes

S.99

Your boiler is currently running through its internal diagnostic safety test upon startup, which is a normal automated process rather than an actual fault.

Low DIY-safe

What to check first

  1. Wait a few moments for the boiler to complete its automated self-test cycle.
  2. Do not attempt to reset or switch off the boiler while the test is in progress.
  3. If the display does not return to normal after a short wait, switch the boiler off and on again.

Related codes

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.