A18 High

Vokera A18 Fault Code

The Vokera A18 fault code means: your boiler's internal computer memory is not communicating correctly with the main control board, preventing the system from starting.. It appears on 1 Vokera model in our database.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description: INCORRECT EEPROM SIGNATURE EEPROM not recognised by the processor

What causes the Vokera A18 fault?

This fault occurs when the boiler's central brain fails to read the permanent memory chip that stores its specific operating instructions. It is usually caused by a hardware malfunction within the electrical circuitry or a communication failure between the memory chip and the control board. Because the boiler cannot verify its own identity or settings, it shuts down for safety reasons.

Typical repair cost £280-450 (including labour)

Engineer required

This fault requires a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.

Find a Gas Safe engineer

Search the official register for a qualified engineer in your area.

Gas Safe Register →

Vokera models that show the A18 fault code

Click a model for the full fault code list and model-specific repair notes.

Source

Vokera A18 fault code information on this page is sourced and cross-checked against the official Vokera service / installation manuals for each affected model.

Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 27 April 2026