Vokera PressureGauge < 0.5 BAR Fault Code
Also written as PRESSUREGAUGE05BAR — same fault.
The Vokera PressureGauge < 0.5 BAR fault code means: your boiler has stopped working because the water level inside the system has dropped too low to operate safely.. It appears on 2 Vokera models in our database.
Technical description: Should the pressure fall below 0.5 BAR, the boiler shuts off automatically.
What causes the Vokera PressureGauge < 0.5 BAR fault?
This fault occurs when the sealed water circuit loses its required pressure, usually due to a small leak in the pipework or at a radiator valve. It can also happen if the expansion vessel has lost its internal air charge, causing water to be forced out of the safety discharge pipe.
This issue often surfaces when you turn your heating back on for autumn, as the sudden change in temperature and pressure can highlight minor leaks that weren't visible in the summer.
DIY fix possible
Locate the filling loop, which is usually a flexible silver hose with one or two small valves underneath the boiler.Slowly open the valve(s) to allow cold water into the system, watching the pressure gauge rise.Close the valves tightly once the pressure gauge reaches between 1.0 and 1.5 BAR.
Find a Gas Safe engineer
Search the official register for a qualified engineer in your area.
Gas Safe Register →Vokera models that show the PressureGauge < 0.5 BAR fault code
Click a model for the full fault code list and model-specific repair notes.
Source
Vokera PressureGauge < 0.5 BAR fault code information on this page is sourced and cross-checked against the official Vokera service / installation manuals for each affected model.
Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 27 April 2026